Seismic design of bridge columns incorporating mechanical bar splices in plastic hinge regions

被引:87
|
作者
Tazarv, Mostafa [1 ]
Saiidi, M. Saiid [2 ]
机构
[1] South Dakota State Univ, Dept Civil & Environm Engn, Brookings, SD 57007 USA
[2] Univ Nevada Reno, Dept Civil & Environm Engn, Reno, NV 89557 USA
关键词
Mechanical bar splices; Couplers; RC bridge columns; Accelerated bridge construction; Seismic performance; Displacement ductility; Plastic hinges length; CONCRETE; REPAIR;
D O I
10.1016/j.engstruct.2016.06.041
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The application of prefabricated bridge elements dates back to more than half a century. Several prefabrication techniques have been developed thereafter for capacity protected bridge elements. However, the application of precast bridge columns in moderate and high seismic regions is scarce mainly because of a lack of performance data pertaining to their connections. One of the precast column connections that has been recently emphasized for accelerated bridge construction (ABC) utilizes mechanical bar splices, which are commonly referred to as couplers. For ABC, couplers have to be generally used in the plastic hinge region of precast columns. This would violate the current bridge seismic design codes ban on the application of couplers in the plastic hinge regions of ductile members. The present study was conducted to (a) identify suitable mechanical bar splices for precast column connections through a state-of-the-art review, (b) develop a generic material model for all coupler types, (c) quantify the coupler effects on the column seismic performance, and (d) develop simple design equations for plastic hinges to facilitate the design and field application of mechanically spliced columns in moderate and high seismic regions. It is proposed that the current code limitation on couplers in plastic hinges be revised based on the findings of the present study. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:507 / 520
页数:14
相关论文
共 50 条
  • [11] Experimental study on the seismic performance of self-centering bridge piers incorporating ECC and superelastic SMA bars in the plastic hinge regions
    Qian, Hui
    Ye, Yixiang
    Yan, Changbin
    Jin, Guangyao
    Li, Can
    Shi, Yifei
    STRUCTURES, 2022, 46 : 1955 - 1967
  • [12] Seismic Performance of Bridge Piers Constructed with PP-ECC at Potential Plastic Hinge Regions
    Jia, Yi
    Zhao, Renda
    Li, Fuhai
    Zhou, Zhidong
    Wang, Yongbao
    Zhan, Yulin
    Shi, Xianming
    MATERIALS, 2020, 13 (08)
  • [13] DISPLACEMENT-BASED DESIGN OF RC BRIDGE COLUMNS IN SEISMIC REGIONS
    KOWALSKY, MJ
    PRIESTLEY, MJN
    MACRAE, GA
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1995, 24 (12): : 1623 - 1643
  • [14] Seismic retrofit study of RC rectangular bridge columns lap-spliced at the plastic hinge zone
    Chang, KC
    Liu, KY
    Chang, SB
    FRP COMPOSITES IN CIVIL ENGINEERING, VOLS I AND II, PROCEEDINGS, 2001, : 869 - 875
  • [15] Seismic Repair of Circular Reinforced Concrete Bridge Columns by Plastic Hinge Relocation with Grouted Annular Ring
    Krish, Zachary F.
    Kowalsky, Mervyn J.
    Nau, James M.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2021, 25 (12) : 2371 - 2405
  • [16] Seismic behaviour of RC columns with welded rebars or mechanical splices of reinforcement
    Kalogeropoulos, George I.
    Tsonos, Alexander-Dimitrios G.
    Konstantinidis, Dimitrios
    EARTHQUAKES AND STRUCTURES, 2019, 17 (03) : 297 - 306
  • [17] Hysteretic behavior of composite bridge columns with plastic hinge enhanced by engineered cementitious composite jacket for seismic resistance
    Di, Jin
    Fan, Jiuhong
    Zhou, Xuhong
    Zhao, Lijun
    Han, Bin
    Qin, Fengjiang
    Zhang, Zhigang
    ENGINEERING STRUCTURES, 2022, 251
  • [18] Plastic hinge regions of prefabricated concrete columns with grouted sleeves and simplified calculation method for plastic hinge length
    Ding, Mengjia
    Xu, Weibing
    Wang, Jin
    Chen, Yanjiang
    Du, Xiuli
    Fang, Rong
    Huang, Xiaomin
    Sun, Hang
    STRUCTURES, 2022, 43 : 710 - 725
  • [19] Plastic Hinge Analysis of Seismic Performance of High Bridge Pier
    Gao, Ruihong
    Chen, Ruilin
    Cao, Sugong
    Tang, Zhang
    Xiao, Xinqiang
    Hu, Hongbo
    INNOVATION IN CIVIL ENGINEERING, ARCHITECTURE AND SUSTAINABLE INFRASTRUCTURE, 2012, 238 : 765 - 768
  • [20] Plastic hinge regions of prefabricated concrete columns with grouted sleeves and simplified calculation method for plastic hinge length
    Ding, Mengjia
    Xu, Weibing
    Wang, Jin
    Chen, Yanjiang
    Du, Xiuli
    Fang, Rong
    Huang, Xiaomin
    Sun, Hang
    Structures, 2022, 43 : 710 - 725