Cementation of an acetabular liner into a well-fixed acetabular shell during revision total hip arthroplasty

被引:25
|
作者
Springer, BD [1 ]
Hanssen, AD [1 ]
Lewallen, DG [1 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, Rochester, MN 55905 USA
来源
JOURNAL OF ARTHROPLASTY | 2003年 / 18卷 / 07期
关键词
cement; acetabular liner; acetabular shell; revision total hip arthroplasty;
D O I
10.1016/S0883-5403(03)00287-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Cementing a polyethylene liner into a well-fixed acetabular shell during revision hip arthroplasty may be appropriate in select patients. The purpose of this Study was to review Our early results with this technique. Sixteen patients with >2-year follow-up or who had any complications at <2 years from surgery were identified. Indications for this technique included: failure of the previous locking mechanism, significant polyethylene wear, malposition of the well-fixed metal shell, and previous removal of the liner with a retained acetabular shell. One acetabular shell has been revised at 13 months for multiple dislocations. Hip scores improved an average of 24.2 points. Radiographs revealed no polyethylene dissociation or acetabular loosening. Complications occurred in 7 patients. Initial results appear successful at providing secure fixation, while preventing the bone loss that might occur with removal of a well-fixed component. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:126 / 130
页数:5
相关论文
共 50 条
  • [41] Aortic thrombosis after acetabular revision of a total hip arthroplasty
    Leung, AG
    Cabanela, ME
    JOURNAL OF ARTHROPLASTY, 1998, 13 (08): : 961 - 965
  • [42] Management strategies for acetabular defects in revision total hip arthroplasty
    Cuckler, JM
    JOURNAL OF ARTHROPLASTY, 2002, 17 (04): : 153 - 156
  • [43] Results of Isolated Femoral Component Revision With Well-Fixed Acetabular Implant Retention
    Park, Kyung Soon
    Yoon, Taek Rim
    Song, Eun Kyoo
    Lee, Keun Bae
    JOURNAL OF ARTHROPLASTY, 2010, 25 (08): : 1188 - 1195
  • [44] Constrained acetabular components in complex revision total hip arthroplasty
    McCarthy, JC
    Lee, J
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) : 210 - 215
  • [45] Management of massive acetabular defects in revision total hip arthroplasty
    Dennis, DA
    JOURNAL OF ARTHROPLASTY, 2003, 18 (03): : 121 - 125
  • [46] Revision arthroplasty of the hip - Acetabular component
    Gollwitzer, H.
    von Eisenhart-Rothe, R.
    Holzapfel, B. M.
    Gradinger, R.
    CHIRURG, 2010, 81 (04): : 284 - +
  • [47] Management of Acetabular Bone Loss in Revision Total Hip Arthroplasty
    Deirmengian, Gregory K.
    Zmistowski, Benjamin
    O'Neil, Joseph T.
    Hozack, William J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (19): : 1842 - 1852
  • [48] Sonographic Detection of Acetabular Polyethylene Liner Dissociation in Total Hip Arthroplasty
    Jin, Wook
    Chun, Young Soo
    Park, So Young
    Rhyu, Kee Hyung
    Park, Ji Seon
    Kim, Hyun Cheol
    Yang, Dal Mo
    Ryu, Kyung Nam
    JOURNAL OF ULTRASOUND IN MEDICINE, 2009, 28 (11) : 1597 - 1600
  • [49] Re-revision of failed revision Total Hip Arthroplasty acetabular components
    Lim, Seung-Jae
    Lee, Young-Suk
    Lim, Byung-Ho
    Park, Youn-Soo
    ACTA ORTHOPAEDICA BELGICA, 2014, 80 (03): : 357 - 364
  • [50] Application of acetabular reinforcement ring with hook for correction of segmental acetabular rim defects during total hip arthroplasty revision
    Jianlin Xiao
    Xin Zhao
    Yiming Wang
    Yuhui Yang
    Jianhui Zhao
    Zhongli Gao
    Jianlin Zuo
    Journal of Bionic Engineering, 2018, 15 : 154 - 159