End-to-end intestinal anastomosis using a novel biodegradable stent for laparoscopic colonic surgery: a multicenter study

被引:6
|
作者
Chen, Mingyu [1 ,2 ]
Cao, Jiasheng [1 ]
Huang, Diyu [1 ]
Zhang, Bin [1 ]
Pan, Long [1 ]
Zhang, Zhongtao [3 ]
Wang, Zhenjun [4 ]
Ye, Yingjiang [5 ]
Xiu, Dianrong [6 ]
Li, Dechuan [7 ]
Cai, Xiujun [1 ,2 ]
机构
[1] Zhejiang Univ, Dept Gen Surg, Sir Run Run Shaw Hosp, 3 East Qingchun Rd, Hangzhou 310016, Peoples R China
[2] Zhejiang Univ, Key Lab Endoscop Tech Res Zhejiang Prov, Sir Run Run Shaw Hosp, Hangzhou 310016, Peoples R China
[3] Capital Med Univ, Dept Gen Surg, Beijing Friendship Hosp, Beijing 100032, Peoples R China
[4] Capital Med Univ, Dept Anorectal Surg, Beijing Chaoyang Hosp, Beijing 100020, Peoples R China
[5] Peking Univ, Peoples Hosp, Dept Gastrointestinal Surg, Beijing 100032, Peoples R China
[6] Peking Univ, Dept Gen Surg, Hosp 3, Beijing 100089, Peoples R China
[7] Zhejiang Canc Hosp, Dept Colorectal Surg, Hangzhou 310011, Peoples R China
关键词
Intestinal anastomosis; A novel stent; Laparoscopic colonic operation; STAPLED ANASTOMOSIS; COLORECTAL SURGERY; ASSISTED COLECTOMY; DEGRADABLE STENT; HAND-SEWN; RING; COMPRESSION; SUTURE; TRIAL;
D O I
10.1007/s00595-019-01841-6
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose Our animal studies have demonstrated the safety and feasibility of end-to-end intestinal anastomosis using a stent for laparoscopic colonic surgery. Therefore, we designed a non-inferiority trial to investigate the outcomes of stent anastomosis (SA) vs. those of conventional hand-sewn anastomosis (CA). Methods A multicenter randomized controlled trial was conducted between December, 2016 and April, 2018. The primary outcome was the healing condition of the anastomoses, evaluated by endoscopy 6 months postoperatively. The secondary outcomes were the anastomotic completion time, anastomotic leak, intestinal obstruction, peritoneal effusion, and bleeding. Quality of life (QOL) was evaluated by questionnaires. Results The subjects of this study were 60 patients, randomly divided into a SA group (n = 30) and a CA group (n = 30). There were no differences in anastomotic healing conditions (P = 1.00). The stent procedure was associated with a significantly shorter anastomosis time than the hand-sewn anastomosis (13.517 +/- 4.281 vs. 20.333 +/- 2.998 min, respectively; P < 0.001). There were no significant differences in anastomotic leakage, intestinal obstruction, peritoneal effusion, or bleeding between the groups. Questionnaires revealed almost no discrepancy between baseline QOL scores and those assessed 2, 4, 8, 12, and 24 weeks postoperatively in either group. Conclusions Intestinal anastomosis with a stent is a non-inferior strategy for laparoscopic colonic surgery, which requires less time for the anastomosis.
引用
收藏
页码:1003 / 1012
页数:10
相关论文
共 50 条
  • [21] THE STAPLED FUNCTIONAL END-TO-END ANASTOMOSIS FOLLOWING COLONIC RESECTION
    KYZER, S
    GORDON, PH
    INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 1992, 7 (03) : 125 - 131
  • [22] END-TO-END COLONIC ANASTOMOSIS - A COMPARISON OF TECHNIQUES IN NORMAL DOGS
    STOLOFF, D
    SNIDER, TG
    CRAWFORD, MP
    TAYLOR, HW
    COX, HU
    VETERINARY SURGERY, 1984, 13 (02) : 76 - 82
  • [23] COLONIC ANASTOMOSIS - EVALUATION OF AN END-TO-END CRUSHING AND INVERTING TECHNIQUE
    RICHARDSON, DC
    DUCKETT, KE
    KRAHWINKEL, DJ
    SHIPMAN, LW
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1982, 43 (03) : 436 - 442
  • [25] A COMPARATIVE STUDY OF INVERTING END-TO-END ANASTOMOSIS VS TELESCOPING END-TO-END ANASTOMOSIS IN DOG INTESTINE
    WHITE, D
    SINGLETO.AO
    TEXAS REPORTS ON BIOLOGY AND MEDICINE, 1967, 25 (03) : 502 - &
  • [26] END COLOSTOMY USING THE END-TO-END ANASTOMOSIS INSTRUMENT
    BURKE, TW
    WEISER, EB
    HOSKINS, WJ
    HELLER, PB
    NASH, JD
    PARK, RC
    OBSTETRICS AND GYNECOLOGY, 1987, 69 (02): : 156 - 159
  • [27] Sliding functional end-to-end anastomosis for colorectal surgery
    Kawahara, Hidejiro
    Hirai, Katsuya
    Watanabe, Kazuhiro
    Kashiwagi, Hideyuki
    Yamazaki, Yoji
    Yanaga, Katsuhiko
    INTERNATIONAL SURGERY, 2007, 92 (01) : 34 - 36
  • [28] EXPERIENCES WITH STAPLER FOR END-TO-END ANASTOMOSIS IN SURGERY OF THE COLON
    BUCHMANN, P
    UHLSCHMID, G
    HOLLINGER, A
    HELVETICA CHIRURGICA ACTA, 1980, 47 (05) : 645 - 649
  • [29] END-TO-END MECHANICAL CIRCULAR ANASTOMOSIS IN DIGESTIVE SURGERY
    LACROIX, A
    ESCAT, J
    FOURTANIER, G
    ANDUZE, Y
    NOUVELLE PRESSE MEDICALE, 1979, 8 (27): : 2279 - 2281
  • [30] A novel knotless hand-sewn end-to-end anastomosis using V-loc barbed suture vs. stapled anastomosis in laparoscopic left colonic surgery: A propensity scoring match analysis
    Xu, Shining
    Zhao, Xuan
    He, Zirui
    Yang, Xiao
    Ma, Junjun
    Dong, Feng
    Zang, Lu
    Fingerhut, Abe
    Zhang, Luyang
    Zheng, Minhua
    FRONTIERS IN SURGERY, 2022, 9