μGC x μGC: Comprehensive Two-Dimensional Gas Chromatographic Separations with Microfabricated Components

被引:37
|
作者
Collin, William R. [1 ,4 ]
Bondy, Amy [1 ]
Paul, Dibyadeep [3 ,4 ]
Kurabayashi, Katsuo [3 ,4 ]
Zellers, Edward T. [1 ,2 ,4 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Environm Hlth Sci, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Mech Engn, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Ctr Wireless Integrated MicroSensing & Syst, Ann Arbor, MI 48109 USA
基金
美国国家科学基金会;
关键词
VOLATILE ORGANIC-COMPOUNDS; THERMAL MODULATOR; IONIC LIQUIDS; PERFORMANCE EVALUATION; COLUMNS; TEMPERATURE; DESORPTION; DESIGN; PHASE; VOC;
D O I
10.1021/ac5032226
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development and characterization of a microanalytical subsystem comprising silicon-micromachined first- and second-dimension separation columns and a silicon-micromachined thermal modulator (mu TM) for comprehensive two-dimensional (i.e., mu GC x mu GC) separations are described. The first dimension consists of two series-coupled 3.1 cm x 3.1 cm mu column chips with etched channels 3 m long and 250 mu m x 140 mu m in cross section, wall-coated with a poly(dimethylsiloxane) (PDMS) stationary phase. The second dimension consists of a 1.2 cm x 1.2 cm mu column chip with an etched channel 0.5 m long and 46 mu m x 150 mu m in cross section wall-coated with either a trigonal tricationic room-temperature ionic liquid (RTIL) or a commercial poly(trifluoropropylmethyl siloxane) (OV-215) stationary phase. The two-stage, cryogen-free mu TM consists of a Si chip containing two series-coupled, square spiral channels 4.2 cm and 2.8 cm long and 250 mu m x 140 mu m in cross section wall-coated with PDMS. Conventional injection methods and flame ionization detection were used. Temperature-ramped separations of a simple alkane mixture using the RTIL-coated second-dimension (2D) mu column produced reasonably good peak shapes and modulation numbers; however, strong retention of polar compounds on the RTIL-coated 2D mu column led to excessively broad peaks with low 2D resolution. Substituting OV-215 as the 2D mu column stationary phase markedly improved the performance, and a structured 22 min chromatogram of a 36-component mixture spanning a vapor pressure range of 0.027 to 13 kPa was generated with modulated peak fwhm (full width at half-maximum) values ranging from 90 to 643 ms and modulation numbers of 1-6.
引用
收藏
页码:1630 / 1637
页数:8
相关论文
共 50 条
  • [21] Moving cryogenic modulator for the comprehensive two-dimensional gas chromatography (GC x GC) of surface water contaminants
    Beens, J
    Dallüge, J
    Adahchour, M
    Vreuls, RJJ
    Brinkman, UAT
    JOURNAL OF MICROCOLUMN SEPARATIONS, 2001, 13 (03) : 134 - 140
  • [22] Recent developments in comprehensive two-dimensional gas chromatography (GC x GC) II. Modulation and detection
    Adahchour, M
    Beens, J
    Vreuls, RJJ
    Brinkman, UAT
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (06) : 540 - 553
  • [23] Proper tuning of comprehensive two-dimensional gas chromatography (GC x GC) to optimize the separation of complex oil fractions
    Beens, J
    Blomberg, J
    Schoenmakers, PJ
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 2000, 23 (03): : 182 - 188
  • [24] Recent developments in comprehensive two-dimensional gas chromatography (GC x GC) III. Applications for petrochemicals and organohalogens
    Adahchour, M.
    Beens, J.
    Vreuls, R. J. J.
    Brinkman, U. A. Th.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (07) : 726 - 741
  • [25] Enhancing the limit of detection for comprehensive two-dimensional gas chromatography (GC x GC) using bilinear chemometric analysis
    Fraga, CG
    Prazen, BJ
    Synovec, RE
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 2000, 23 (03): : 215 - 224
  • [26] Quantitative determination of BTEX and total aromatic compounds in gasoline by comprehensive two-dimensional gas chromatography (GC x GC)
    Frysinger, GS
    Gaines, RB
    Ledford, EB
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1999, 22 (04): : 195 - 200
  • [27] Optimization of comprehensive two-dimensional gas-chromatography (GC x GC) mass spectrometry for the determination of essential oils
    Omar, Jone
    Alonso, Bone
    Olivares, Maitane
    Vallejo, Asier
    Etxebarria, Nestor
    TALANTA, 2012, 88 : 145 - 151
  • [28] Comprehensive two-dimensional gas chromatography with mass spectrometric detection (GC x GC/MS) applied to the analysis of petroleum
    Frysinger, GS
    Gaines, RB
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1999, 22 (05): : 251 - 255
  • [29] Polymer-coated micro-optofluidic ring resonator detector for a comprehensive two-dimensional gas chromatographic microsystem: μGC x μGC-μOFRR
    Collin, William R.
    Scholten, Kee W.
    Fan, Xudong
    Paul, Dibyadeep
    Kurabayashi, Katsuo
    Zellers, Edward T.
    ANALYST, 2016, 141 (01) : 261 - 269
  • [30] Single-jet, single-stage cryogenic modulator for comprehensive two-dimensional gas chromatography (GC x GC)
    Adahchour, M
    Beens, J
    Brinkman, UAT
    ANALYST, 2003, 128 (03) : 213 - 216