Quantitative analysis of chemical warfare agent degradation products in reaction masses using capillary electrophoresis

被引:43
|
作者
Nassar, AEF
Lucas, SV
Myler, CA
Jones, WR
Campisano, M
Hoffland, LD
机构
[1] Battelle Mem Inst, Bel Air, MD 21015 USA
[2] Thermo BioAnal Corp, Franklin, MA 02038 USA
[3] USA, Mat Command Treaty Lab, Aberdeen Proving Ground, MD 21010 USA
关键词
D O I
10.1021/ac9713870
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantitative methods have been developed for the analysis of chemical warfare agent degradation products in reaction masses using capillary electrophoresis (CE), This is the first report of a systematic validation of a CE-based method for the analysis of chemical warfare agent degradation products in agent neutralization matrixes (reaction masses). After neutralization with monoethanolamine/water, the nerve agent GB (isopropyl methylphosphonofluoridate, Sarin) gives isopropyl methylphosphonic acid (IMPA) and O-isopropyl O'-(2-amino)ethyl methylphosphonate (GB-MEA adduct). The nerve agent GD (pinacolyl methylphosphonofluoridate, Soman), [pinacolyl= 2-(3,3-dimethyl)butyl] produces pinacolyl methylphosphonic acid (PMPA) and O-pinacolyl O'-(2-amino)ethyl methylphosphonate (GD-MEA adduct), The samples were prepared by dilution of the reaction masses with deionized water before analysis by CE/indirect UV detection or CE/conductivity detection. Migration time precision was less than 4.0% RSD for IMPA and 5.0% RSD for PMPA on a day-to-day basis. The detection limit for both IMPA and PMPA is 100 mu g/L; the quantitation limit for both is 500 mu g/L. For calibration standards, IMPA and PMPA gave a linear response (R-2 = 0.9999) over the range 0.5-100 mu g/mL. The interday precision RSDs were 1.9, 1.0, and 0.7% for IMPA at 7.5, 37.5 and 75.0 mu g/mL, respectively, Corresponding values for PMPA (again, RSD) were 2.9, 1.1, and 1.0% at 7.5, 37.5 and 87.5 mu g/mL, respectively, as before. Analysis accuracy was assessed by spiking actual neutralization samples with IMPA or PMPA. For IMPA, the seven spike levels used ranged from 20 to 220% of the IMPA background level, and the incremental change in the found IMPA level ranged from 86 to 99% of the true spiking increment (R2 = 0.9987 for the linear regression). For PMPA, the five spike levels ranged from 10 to 150% of the matrix background level, and similarly, the accuracy obtained ranged from 95 to 97% of the true incremental value (R-2 = 0.9999 for the linear regression).
引用
收藏
页码:3598 / 3604
页数:7
相关论文
共 50 条
  • [31] Determination of chemical warfare agent degradation products at low-part-per-billion levels in aqueous samples and sub-part-per-million levels in soils using capillary electrophoresis
    Nassar, AEF
    Lucas, SV
    Hoffland, LD
    ANALYTICAL CHEMISTRY, 1999, 71 (07) : 1285 - 1292
  • [32] Capillary ion electrophoresis screening of nerve agent degradation products in environmental samples using conductivity detection
    Rosso, TE
    Bossle, PC
    JOURNAL OF CHROMATOGRAPHY A, 1998, 824 (01) : 125 - 134
  • [33] Infrared signatures of thermal degradation products from chemical warfare agent simulants
    Gese, Natalie
    Eilers, Hergen
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES, CBRNE SENSING XXV, 2024, 13056
  • [34] Hand-Held Analyzer Based on Microchip Electrophoresis with Contactless Conductivity Detection for Measurement of Chemical Warfare Agent Degradation Products
    Duran, Karolina-Petkovic
    Zhu, Yonggang
    Chen, Chuanpin
    Swallow, Anthony
    Stewart, Robert
    Hoobin, Pam
    Leech, Patrick
    Ovenden, Simon
    BIOMEDICAL APPLICATIONS OF MICRO- AND NANOENGINEERING IV AND COMPLEX SYSTEMS, 2008, 7270
  • [35] CE-MS-MS for the identification of chemical warfare agent degradation products
    Lagarrigue, Melanie
    Bossee, Anne
    Begos, Arlette
    Varennet, Anne
    Gareil, Pierre
    Bellier, Bruno
    LC GC NORTH AMERICA, 2007, 25 (03) : 292 - +
  • [36] Analysis of organophosphorus chemical warfare (CWA), their precursors and degradation products
    Nyvltová, Z
    Paryzková, J
    Cermák, J
    Churácek, J
    CHEMICKE LISTY, 1999, 93 (03): : 181 - 190
  • [37] Cytotoxicity of arsenic-containing chemical warfare agent degradation products with metallomic approaches for metabolite analysis
    Kroening, Karolin K.
    Solivio, Morwena J. V.
    Garcia-Lopez, Monica
    Puga, Alvaro
    Caruso, Joseph A.
    METALLOMICS, 2009, 1 (01) : 59 - 66
  • [38] Analysis of the Precursors, Simulants and Degradation Products of Chemical Warfare Agents
    Witkiewicz, Zygfryd
    Neffe, Slawomir
    Sliwka, Ewa
    Quagliano, Javier
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2018, 48 (05) : 337 - 371
  • [39] Application of microcolumn liquid chromatography and capillary electrophoresis with flame photometric detection for the screening of degradation products of chemical warfare agents in water and soil
    Hooijschuur, EWJ
    Kientz, CE
    Brinkman, UAT
    JOURNAL OF CHROMATOGRAPHY A, 2001, 928 (02) : 187 - 199
  • [40] Separation and identification of isomeric acidic degradation products of organophosphorus chemical warfare agents by capillary electrophoresis-ion trap mass spectrometry
    Lagarrigue, Melanie
    Bossee, Anne
    Begos, Arlette
    Varenne, Anne
    Gareil, Pierre
    Bellier, Bruno
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1137 (01) : 110 - 118