Gradient-based 3D-2D Registration of Cerebral Angiograms

被引:1
|
作者
Mitrovic, Uros [1 ]
Markelj, Primoz [1 ,2 ]
Likar, Bostjan [1 ,2 ]
Milosevic, Zoran [3 ]
Pernus, Franjo [1 ,2 ]
机构
[1] Univ Ljubljana, Fac Elect Engn, Lab Imaging Technol, Ljubljana 61000, Slovenia
[2] Sensum Comp Vis Syst, Ljubljana 1000, Slovenia
[3] Univ Ljubljana, Fac Med, Dept Radiol, Ljubljana, Slovenia
来源
关键词
3D-2D registration; gold standard; cerebral angiograms; gradient-based; evaluation; CTA; STANDARDIZED EVALUATION METHODOLOGY; 3D/2D REGISTRATION;
D O I
10.1117/12.877541
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Endovascular treatment of cerebral aneurysms and arteriovenous malformations (AVM) involves navigation of a catheter through the femoral artery and vascular system into the brain and into the aneurysm or AVM. Intra-interventional navigation utilizes digital subtraction angiography (DSA) to visualize vascular structures and X-ray fluoroscopy to localize the endovascular components. Due to the two-dimensional (2D) nature of the intra-interventional images, navigation through a complex three-dimensional (3D) structure is a demanding task. Registration of pre-interventional MRA, CTA, or 3D-DSA images and intra-interventional 2D DSA images can greatly enhance visualization and navigation. As a consequence of better navigation in 3D, the amount of required contrast medium and absorbed dose could be significantly reduced. In the past, development and evaluation of 3D-2D registration methods received considerable attention. Several validation image databases and evaluation criteria were created and made publicly available in the past. However, applications of 3D-2D registration methods to cerebral angiograms and their validation are rather scarce. In this paper, the 3D-2D robust gradient reconstruction-based (RGRB) registration algorithm is applied to CTA and DSA images and analyzed. For the evaluation purposes five image datasets, each comprised of a 3D CTA and several 2D DSA-like digitally reconstructed radiographs (DRRs) generated from the CTA, with accurate gold standard registrations were created. A total of 4000 registrations on these five datasets resulted in mean mTRE values between 0.07 and 0.59 mm, capture ranges between 6 and 11 mm and success rates between 61 and 88% using a failure threshold of 2 mm.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] A quick 3D-2D registration method for a wide-range of applications
    Kita, Y
    Wilson, DL
    Noble, JA
    Kita, N
    15TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOL 1, PROCEEDINGS: COMPUTER VISION AND IMAGE ANALYSIS, 2000, : 981 - 986
  • [32] A Fast DRR Generation Scheme for 3D-2D Image Registration Based on the Block Projection Method
    Mu, Zhiping
    PROCEEDINGS OF 29TH IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS, (CVPRW 2016), 2016, : 609 - 617
  • [33] In vivo kinematic study of the tarsal joints complex based on fluoroscopic 3D-2D registration technique
    Wang, Chen
    Geng, Xiang
    Wang, Shaobai
    Ma, Xin
    Wang, Xu
    Huang, Jiazhang
    Zhang, Chao
    Chen, Li
    Yang, Junsheng
    Wang, Kan
    GAIT & POSTURE, 2016, 49 : 54 - 60
  • [34] Dynamic Tracking of a Deformable Tissue Based on 3D-2D MR-US Image Registration
    Marami, Bahram
    Sirouspour, Shahin
    Fenster, Aaron
    Capson, David W.
    MEDICAL IMAGING 2014: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2014, 9036
  • [35] Neural patient-specific 3D-2D registration in laparoscopic liver resection
    Mhiri, Islem
    Pizarro, Daniel
    Bartoli, Adrien
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2025, 20 (01) : 57 - 64
  • [36] 3D-2D registration in mobile radiographs: algorithm development and preliminary clinical evaluation
    Otake, Yoshito
    Wang, Adam S.
    Uneri, Ali
    Kleinszig, Gerhard
    Vogt, Sebastian
    Aygun, Nafi
    Lo, Sheng-fu L.
    Wolinsky, Jean-Paul
    Gokaslan, Ziya L.
    Siewerdsen, Jeffrey H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (05): : 2075 - 2090
  • [37] 3D-2D Medical Image Registration Technology and Its Application Development: a Survey
    Xiao, Handan
    PROCEEDINGS OF 2023 4TH INTERNATIONAL SYMPOSIUM ON ARTIFICIAL INTELLIGENCE FOR MEDICINE SCIENCE, ISAIMS 2023, 2023, : 95 - 100
  • [38] 2D-3D registration of coronary angiograms for cardiac procedure planning and guidance
    Turgeon, GA
    Lehmann, G
    Guiraudon, G
    Drangova, M
    Holdsworth, D
    Peters, T
    MEDICAL PHYSICS, 2005, 32 (12) : 3737 - 3749
  • [39] Deformable 3D-2D registration for CT and its application to low dose tomographic fluoroscopy
    Flach, Barbara
    Brehm, Marcus
    Sawall, Stefan
    Kachelriess, Marc
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (24): : 7865 - 7887
  • [40] Efficient Similarity Measurement between Digitally Reconstructed Radiograph and Fluoroscopy for 3D-2D Registration
    Rao, Chaitanya R. H.
    Anitha, H.
    Bhat, Shyamasunder N.
    Bhat, Vidya
    2018 INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTING, COMMUNICATIONS AND INFORMATICS (ICACCI), 2018, : 611 - 616