Tailoring the biologic responses of 3D printed PEEK medical implants by plasma functionalization

被引:29
|
作者
Han, Xingting [1 ,2 ]
Sharma, Neha [3 ,4 ]
Spintzyk, Sebastian [2 ,5 ]
Zhou, Yongsheng [1 ]
Xu, Zeqian [2 ,6 ,7 ,8 ,9 ,10 ,11 ]
Thieringer, Florian M. [3 ,4 ]
Rupp, Frank [2 ]
机构
[1] Peking Univ Sch & Hosp Stomatol, Natl Ctr Stomatol, Natl Clin Res Ctr Oral Dis,Dept Prosthodont,NHC K, Natl Engn Lab Digital & Mat Technol Stomatol,Beij, 22 Zhongguancun Ave South, Beijing 100081, Peoples R China
[2] Univ Hosp Tubingen, Sect Med Mat Sci & Technol, Osianderstr 2-8, D-72076 Tubingen, Germany
[3] Univ Basel, Hightech Res Ctr, Dept Biomed Engn, Med Addit Mfg Res Grp, Allschwil, Switzerland
[4] Univ Hosp Basel, Dept Oral & Craniomaxillofacial Surg, Basel, Switzerland
[5] Carinthia Univ Appl Sci, Sch Engn & IT, ADMiRE Lab Addit Mfg Intelligent Robot Sensors &, Villach, Austria
[6] Shanghai Jiao Tong Univ, Sch Med, Shanghai Peoples Hosp 9, Dept Prosthodont, Shanghai, Peoples R China
[7] Shanghai Jiao Tong Univ, Coll Stomatol, Shanghai, Peoples R China
[8] Natl Ctr Stomatol Natl Clin Res Ctr Oral Dis, Shanghai, Peoples R China
[9] Natl Clin Res Ctr Oral Dis, Shanghai, Peoples R China
[10] Shanghai Key Lab Stomatol, Shanghai, Peoples R China
[11] Shanghai Engn Res Ctr Adv Dent Technol & Mat, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Polyetheretherketone; Fused Filament Fabrication; Plasma surface treatment; Wettability; Bioactivity; LOW-PRESSURE PLASMA; IN-VITRO; POLYETHERETHERKETONE; BIOACTIVITY; OSSEOINTEGRATION; OSTEOGENESIS; OSTEOBLASTS; PROPERTY; IMPACT; VIVO;
D O I
10.1016/j.dental.2022.04.026
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The objective of this study was to determine the effect of two plasma surface treatments on the biologic responses of PEEK medical implants manufactured by fused filament fabrication (FFF) 3D printing technology. Methods: This study created standard PEEK samples using an FFF 3D printer. After fabrication, half of the samples were polished to simulate a smooth PEEK surface. Then, argon (Ar) or oxygen (O-2) plasma was used to modify the bioactivity of FFF 3D printed and polished PEEK samples. Scanning electron microscopy (SEM) and a profilometer were used to determine the microstructure and roughness of the sample surfaces. The wettability of the sample surface was assessed using a drop shape analyzer (DSA) after plasma treatment and at various time points following storage in a closed environment. Cell adhesion, metabolic activity, proliferation, and osteogenic differentiation of SAOS-2 osteoblasts were evaluated to determine the in vitro osteogenic activity. Results: SEM analysis revealed that several spherical nanoscale particles and humps appeared on sample surfaces following plasma treatment. The wettability measurement demonstrated that plasma surface treatment significantly increased the surface hydrophilicity of PEEK samples, with only a slight aging effect found after 21 days. Cell adhesion, spreading, proliferation, and differentiation of SAOS-2 osteoblasts were also up-regulated after plasma treatment. Additionally, PEEK samples treated with O-2 plasma demonstrated a higher degree of bioactivation than those treated with Ar. Significance: Plasma-modified PEEK based on FFF 3D printing technology was a feasible and prospective bone grafting material for bone/dental implants. (C) 2022 The Author(s). Published by Elsevier Inc. on behalf of The Academy of Dental Materials.
引用
收藏
页码:1083 / 1098
页数:16
相关论文
共 50 条
  • [31] Mechanical Properties Tailoring of 3D Printed Photoresponsive Nanocellulose Composites
    Mueller, Luca A. E.
    Zimmermann, Tanja
    Nystroem, Gustav
    Burgert, Ingo
    Siqueira, Gilberto
    ADVANCED FUNCTIONAL MATERIALS, 2020, 30 (35)
  • [32] Tailoring 3D printed concrete through explainable artificial intelligence
    Ghasemi, Alireza
    Naser, M. Z.
    STRUCTURES, 2023, 56
  • [33] Tailoring mechanical properties in 3D printed multimaterial architected structures
    Mehrpouya, Mehrshad
    Ghalayaniesfahani, Ava
    Postmes, Jonne F.
    Gibson, Ian
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2024, 152
  • [34] Determining the effect of porosities on the hydrogen adsorption capacity of 3D printed PEEK
    Tabrizi, Arvin Taghizadeh
    Aghajani, Hossein
    Mashtizadeh, Amirreza
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 49 : 1009 - 1019
  • [35] Bionic design and verification of 3D printed PEEK costal cartilage prosthesis
    Zhang, Chenguang
    Wang, Ling
    Kang, Jianfeng
    Fuentes, Oscar Martel
    Li, Dichen
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 103
  • [36] Surface functionalization of 3D printed structures: Aesthetic and antibiofouling properties
    Castro, Jose D.
    Carneiro, E.
    Marques, S. M.
    Figueiredo, Bruno
    Pontes, Antonio J.
    Sampaio, Alvaro M.
    Carvalho, Isabel
    Henriques, Mariana
    Cruz, Paulo J. S.
    Carvalho, S.
    SURFACE & COATINGS TECHNOLOGY, 2020, 386
  • [37] An In Vitro Study of Osteoblast Response on Fused-Filament Fabrication 3D Printed PEEK for Dental and Cranio-Maxillofacial Implants
    Han, Xingting
    Sharma, Neha
    Xu, Zeqian
    Scheideler, Lutz
    Geis-Gerstorfer, Jurgen
    Rupp, Frank
    Thieringer, Florian M.
    Spintzyk, Sebastian
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (06)
  • [38] Translation of 3D printed materials for medical applications
    Amit Bandyopadhyay
    Susmita Bose
    Roger Narayan
    MRS Bulletin, 2022, 47 : 39 - 48
  • [39] Translation of 3D printed materials for medical applications
    Bandyopadhyay, Amit
    Bose, Susmita
    Narayan, Roger
    MRS BULLETIN, 2022, 47 (01) : 39 - 48
  • [40] 3D printed tooling for thermoforming of medical devices
    Chimento, Jairo
    Highsmith, M. Jason
    Crane, Nathan
    RAPID PROTOTYPING JOURNAL, 2011, 17 (05) : 387 - 392