Fire resistance of T-shaped concrete-filled steel tubular columns under eccentric compression

被引:6
|
作者
Liu, Jiepeng [1 ,2 ]
Wei, Xuan [1 ,2 ]
Yang, Yuanlong [1 ,2 ]
Yang, Weiqi [1 ,2 ]
Chen, Y. Frank [3 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[2] Chongqing Univ, Key Lab New Technol Construct Cities Mt Area, Minist Educ, Chongqing 400045, Peoples R China
[3] Penn State Univ, Dept Civil Engn, Middletown, PA 17057 USA
基金
中国国家自然科学基金;
关键词
T-shaped CFST columns; Fire test; Eccentric compression; Fire resistance; Simplified calculation formula; STUB COLUMNS; BEHAVIOR; PERFORMANCE;
D O I
10.1016/j.jcsr.2021.106973
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to study the fire resistance of T-shaped concrete-filled steel tubular (CFST) columns subjected to eccentric loading, a series of fire tests were conducted along with a numerical study. Specifically, six half-scaled T-shaped CFST columns were tested under the ISO-834 standard fire; and the parameters of stiffener type, load eccentricity, and load angle were considered. The failure modes, thermal response, and structural response were investigated. The test results show that the fire resistance of T-shaped CFST columns decreases with the increase of load eccentricity, but at a lesser degree for relatively high eccentricity. The load angle also has a significant influence on the fire resistance of the columns. A finite element (FE) analysis was then conducted to establish the temperature field model and the thermo-mechanical coupling model which were both validated by the test results. Furthermore, an extensive parametric study including 2008 FE analyses was carried out to investigate the effects of key parameters on the fire resistance of T-shaped CFST columns, including load ratio (n), slenderness ratio (lambda), column limb width (B), column limb depth-to-width ratio (D/B), load eccentricity ratio (e/r(0)), steel ratio (alpha(s)), material strength (f(y) and f(ck)), and load angle (theta). The parametric study indicates that the load ratio n has a significant effect on the fire resistance of T-shaped CFST columns and the other parameters also have certain influences on the fire resistance when n < 0.5. Based on the numerical studies, a simplified method to calculate the fire resistance of T-shaped CFST columns is proposed.
引用
收藏
页数:24
相关论文
共 50 条
  • [21] Behavior of concrete-filled T-shaped steel tubular beam-columns under biaxial compressive loads
    Lei, Min
    Li, Ying-Lei
    Li, Yuan-Qi
    Zhang, Jicheng
    Liu, Dewen
    ENGINEERING STRUCTURES, 2023, 277
  • [22] Experimental and numerical analysis on rectangular concrete-filled steel tubular columns with T-shaped stiffeners
    Chen, Shaozhen
    Liu, Yuan
    Luo, Jinhui
    Gao, Shuyu
    JOURNAL OF BUILDING ENGINEERING, 2022, 45
  • [23] Experimental and numerical analysis on rectangular concrete-filled steel tubular columns with T-shaped stiffeners
    Chen, Shaozhen
    Liu, Yuan
    Luo, Jinhui
    Gao, Shuyu
    Journal of Building Engineering, 2022, 45
  • [24] Studies on T-Shaped composite columns consist of multi separate concrete-filled square tubular steel sections under eccentric axial load
    Rong, Bin
    You, Guangchao
    Zhang, Ruoyu
    Feng, Changxi
    Liu, Rui
    STEEL AND COMPOSITE STRUCTURES, 2016, 22 (02): : 217 - 234
  • [25] Experimental study on normal section compression bearing capacity of composite T-shaped concrete-filled steel tubular columns
    Xu, Lihua
    Du, Guofeng
    Wen, Fang
    Xu, Haoran
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2009, 42 (06): : 14 - 21
  • [26] Eccentric compressive behavior of multi-cell T-shaped concrete-filled steel tubular columns at different loading angles
    Zheng Y.
    Liang W.
    Lin Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (12): : 145 - 156
  • [27] Study on behavior of composite T-shaped concrete filled steel tubular short columns under axial compression
    Du, Guo-Feng
    Xu, Li-Hua
    Xu, Hao-Ran
    Wen, Fang
    Xi'an Jianzhu Keji Daxue Xuebao/Journal of Xi'an University of Architecture and Technology, 2008, 40 (04): : 549 - 555
  • [28] Fire resistance of concrete-filled high strength steel tubular columns
    Wang, Ke
    Young, Ben
    THIN-WALLED STRUCTURES, 2013, 71 : 46 - 56
  • [29] Fire Resistance Tests of Concrete-Filled Stainless Steel Tubular Columns
    Ghannam, Mohamed
    Tao, Zhong
    Song, Tian Yi
    Composite Construction in Steel and Concrete VII, 2016, : 468 - 478
  • [30] Compressive behavior of T-shaped concrete filled steel tubular columns
    Yuanlong Yang
    Hua Yang
    Sumei Zhang
    International Journal of Steel Structures, 2010, 10 : 419 - 430