Depth-resolved fluorescence lifetime spectroscopy across the cornea in the digital frequency domain

被引:0
|
作者
Srinivas, Sangly P. [1 ]
Sun, Yuansheng [2 ]
Povrozin, Yevgen [2 ]
Redes, Norin [2 ]
Ranganath, Sudhir H. [3 ]
Damale, Sahana [4 ]
Sushma, T. [4 ]
Barbieri, Beniamino [2 ]
机构
[1] Indiana Univ, Sch Optometry, Bloomington, IN 47405 USA
[2] ISS Inc, Champaign, IL 61822 USA
[3] Siddaganga Inst Technol, Dept Chem Engn, Bio INvENT Lab, Tumakuru, India
[4] DSCE, Bangalore, Karnataka, India
关键词
D O I
10.1117/12.2609950
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
The cornea is the primary refractive component of the eye with a central connective tissue (stroma) which is bounded by stratified epithelium (forms the anterior surface) and endothelium (forms the posterior monolayer). It is transparent to visible light and hence amenable to fluorescence spectroscopy. Here we report on developing a dedicated ophthalmic time-resolved confocal scanning microfluorometer (OTR-CSMF) for depth-resolved transcorneal spectroscopy. The instrument combines a confocal microfluorometer, nanostage, digital frequency domain unit for rapid lifetime acquisition, and a corneal perfusion system. Using a 40x objective (0.8 NA; wd = 3.3 mm; water), the instrument offers depth scanning with an axial resolution of similar to 1.3 mu m and single-molecule detection sensitivity, validated by correlation spectroscopy with fluorescein (100 pM). In addition, the device can resolve fluorescence lifetimes from 100 ps to 100 ms. With porcine corneas ex vivo, topical administration of Rhodamine B showed fluorescence peaks in the epithelium and endothelium consistent with its lipophilicity and consequent accumulation in the cellular layers. Moreover, the high axial resolution of the instrument revealed (a) fluorescence discontinuities at the interface between epithelium and stroma and between stroma and endothelium, and (b) fluorescence spikes in the stroma corresponding to dye accumulation in the keratocytes. These data indicate transcorneal transport of Rhodamine B by sequential diffusion and partitioning. The lifetime of Rhodamine B revealed characteristic variations across the depth, potentially due to variable dye accumulation and/or local variations in the refractive index. Similar experiments with the relatively hydrophilic fluorescein showed high fluorescence in the stroma compared to the cellular layers. Overall, OTR-CSMF is optimized for transcorneal fluorescence spectroscopy. Accordingly, we envision applying the device to register transcorneal dynamics of pO(2), temperature, pH, fluorescent drug surrogates, and electrolytes, among other parameters in the future. These measurements can be expected to revitalize investigations related to drug discovery and the pathophysiology of corneal disorders.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] Fluorescence lifetime standards for time and frequency domain fluorescence spectroscopy
    Boens, Noel
    Qin, Wenwu
    Basaric, Nikola
    Hofkens, Johan
    Ameloot, Marcel
    Pouget, Jacques
    Lefevre, Jean-Pierre
    Valeur, Bernard
    Gratton, Enrico
    vandeVen, Martin
    Silva, Norberto D., Jr.
    Engelborghs, Yves
    Willaert, Katrien
    Sillen, Alain
    Rumbles, Garry
    Phillips, David
    Visser, Antonie J. W. G.
    van Hoek, Arie
    Lakowicz, Joseph R.
    Malak, Henryk
    Gryczynski, Ignacy
    Szabo, Arthur G.
    Krajcarski, Don T.
    Tamai, Naoto
    Miura, Atsushi
    ANALYTICAL CHEMISTRY, 2007, 79 (05) : 2137 - 2149
  • [12] Depth-resolved Mueller matrix polarimetry microscopy of the rat cornea
    Du Le, V. N.
    Saytashev, Ilyas
    Saha, Sudipta
    Lopez, Pedro F.
    Laughrey, Megan
    Ramella-Roman, Jessica C.
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (10): : 5982 - 5994
  • [13] Depth-resolved analysis of biofilms by photoacoustic spectroscopy
    Schmid, T
    Kazarian, L
    Panne, U
    Niessner, R
    ANALYTICAL SCIENCES, 2001, 17 : S574 - S577
  • [14] Depth-resolved near-infrared spectroscopy
    Nerella, NG
    Drennen, JK
    APPLIED SPECTROSCOPY, 1996, 50 (02) : 285 - 291
  • [15] Depth-resolved near-infrared spectroscopy
    Duquesne Univ, Pittsburgh, United States
    Appl Spectrosc, 2 (285-291):
  • [16] Depth-resolved NIR-II fluorescence mesoscope
    Liao, Jiuling
    Yin, Yixuan
    Yu, Jia
    Zhang, Rongli
    Wu, Ting
    Li, Hui
    Sun, Qinchao
    Zhang, Labao
    Zheng, Wei
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (05) : 2366 - 2372
  • [17] Analysis of Light Penetration Depth in Apple Tissues by Depth-Resolved Spatial-Frequency Domain Imaging
    Zhou, Tongtong
    Hu, Dong
    Qiu, Dekai
    Yu, Shengqi
    Huang, Yuping
    Sun, Zhizhong
    Sun, Xiaolin
    Zhou, Guoquan
    Sun, Tong
    Peng, Hehuan
    FOODS, 2023, 12 (09)
  • [18] Fluorescence lifetime of Rhodamine B across the cornea
    Srinivas, Sangly P.
    Sun, Yuansheng
    Povrozin, Eugene
    Redes, Norin
    Barbieri, Beniamino
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (09)
  • [19] Depth-resolved low-coherent backscattering spectroscopy
    Kim, YL
    Liu, Y
    Turzhitsky, V
    Wali, RK
    Roy, HK
    Backman, V
    Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine IX, 2005, 5690 : 297 - 307
  • [20] Depth resolved spectroscopy by frequency domain optical coherence tomography
    Leitgeb, R
    Wojtkowski, M
    Hitzenberger, CK
    Fercher, AF
    Sticker, M
    Kowalczyk, A
    PHOTON MIGRATION, DIFFUSE SPECTROSCOPY AND OPTICAL COHERENCE TOMOGRAPHY: IMAGING AND FUNCTIONAL ASSESSMENT, 2000, 4160 : 57 - 62