Feasibility of deformable structure registration towards calculation of cumulative dose distributions

被引:0
|
作者
Xiong, L
Viswanathan, A
Stewart, A
Haker, S
Tempany, C
Cormack, R
机构
[1] Brigham & Womens Hosp, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
关键词
D O I
10.1118/1.1997644
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Cumulative dose distribution in fractionated radiation therapy is one means to evaluate the risk of complications. Yet the calculation of the distribution is highly challenging due to inter‐fraction change in anatomic geometry. This work presents an algorithm for deformable image registration of bladder and cumulative dose calculation in the setting of HDR brachy‐therapy for vaginal cylinder treatment. Method and Materials: CT scans were obtained on 20 patients with gynecological cancer who received fractionated high dose rate brachy‐therapy to the vaginal cuff, with the vaginal cylinder in situ. As part of an IRB approved study, the patients' bladder filling status was intentionally different for each fraction. The bladder was manually contoured for each treatment fraction and its surface was extracted for input to a biomechanical deformable registration algorithm, which models the structure surface as a thin elastic sheet. Three anatomic correspondence points were identified for each fraction. In three patients we observed additional identifiable landmarks against the bladder wall. These extra markers as shown in each fraction were compared with their predicted location based on both the affine and deformable registration. Results: Compared to the bladder volume at the time of the first fraction, the ratio of the bladder volumes for later fractions ranged from 30 to 300%. Rigid and affine registration of the bladder showed poor correlation of the landmark locations. The deformable registration algorithm significantly improved the accuracy of the correlation. While validation was possible for only three patients, eight independent tests were done for different fractions. Conclusion: The deformable registration algorithm provides a means of tracking points on structures despite significant change in size and shape. While further validation is needed, this approach provides a means to calculate cumulative dose distributions that were not previously feasible. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1942 / 1942
页数:1
相关论文
共 50 条
  • [41] Tumour delineation and cumulative dose computation in radiotherapy based on deformable registration of respiratory correlated CT images of lung cancer patients
    de Xivry, Jonathan Orban
    Janssens, Guillaume
    Bosmans, Geert
    De Craene, Mathieu
    Dekker, Andre
    Buijsen, Jeroen
    van Baardwijk, Angela
    De Ruysscher, Dirk
    Macq, Benoit
    Lambin, Philippe
    RADIOTHERAPY AND ONCOLOGY, 2007, 85 (02) : 232 - 238
  • [42] An Anthropopathic Deformable Phantom for Geometric and Dose Accumulation Accuracy Validation of Deformable Image Registration
    Liao, Y.
    Chen, H.
    Chen, J.
    Gu, X.
    Zhen, X.
    Zhou, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3884 - 3884
  • [43] Feasibility of a Novel Evaluation Method for Deformable Image Registration-Based Dose Accumulation for HDR Brachytherapy with a 3D-Printed Deformable Phantom
    Abe, K.
    Kadoya, N.
    Hashimoto, S.
    Miyasaka, Y.
    Nakajima, Y.
    Ito, K.
    Sato, K.
    Takeda, K.
    Jingu, K.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [44] DOSE MAPPING BASED ON DEFORMABLE REGISTRATION TO RELATE DOSE OUTSIDE THE PROSTATE WITH FAILURE
    Cazoulat, G.
    Witte, M.
    van Herk, M.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S68 - S69
  • [45] Effect of deformable registration uncertainty on lung SBRT dose accumulation
    Samavati, Navid
    Velec, Michael
    Brock, Kristy K.
    MEDICAL PHYSICS, 2016, 43 (01) : 233 - 240
  • [46] Deformable registration for dose accumulation: Current status and future challenges
    Brock, K.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S848 - S848
  • [47] Therapy: Deformable Image Registration, Contour Propagation, and Dose Mapping
    Brock, K.
    Svensson, S.
    Mlyn, M.
    Fox, T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3672 - 3673
  • [48] A System to Evaluate Uncertainty in Accumulated Dose by Deformable Image Registration
    Ahunbay, E. E.
    Ates, O.
    Li, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : S224 - S224
  • [49] Dose Deformation Error Associated with Deformable Image Registration Pathways
    Surucu, M.
    Woerner, A.
    Roeske, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3779 - 3779
  • [50] Preferred MRI Registration Techniques for Deformable Dose Accumulation in Abdomen
    Kainz, K.
    Alvarez, J.
    Zhong, H.
    Tai, A.
    Ahunbay, E.
    Li, X.
    MEDICAL PHYSICS, 2022, 49 (06) : E707 - E708