Preliminary validation study of the 3-min wrist-worn psychomotor vigilance test

被引:10
|
作者
Matsangas, Panagiotis [1 ]
Shattuck, Nita Lewis [1 ]
Brown, Stephanie [1 ]
机构
[1] Naval Postgrad Sch, Dept Operat Res, 1411 Cunningham Dr, Monterey, CA 93943 USA
关键词
Psychomotor vigilance task; Reaction time; Field data collection; SLEEP-DEPRIVATION; TEST PVT; PERFORMANCE; TASK; SENSITIVITY; OPERATIONS; ALERTNESS; RARE;
D O I
10.3758/s13428-016-0821-2
中图分类号
B841 [心理学研究方法];
学科分类号
040201 ;
摘要
The 10-min psychomotor vigilance test (PVT) is a widely used tool to assess behavioral alertness. In operational environments, however, the 3-min version of the PVT is more practicable. Under controlled laboratory conditions, we compared performance on the 3-min PVT on a wrist-worn device with the 3-min PVT on a laptop computer. We conducted two repeated measures experiments (72 participants) to assess the effects of PVT device type (laptop or wrist-worn), backlight on the wrist-worn device (on or off), ambient light (low or normal levels), and interstimulus interval (ISI). First, we compared the wrist-worn PVT (ISI of 2-10 s) with the laptop-based PVT (ISI of 1-4 s). Participants performed six PVT trials counterbalanced for order of ambient light and device type. In both ambient-lighting conditions, the median differences in PVT metrics (reaction time, response speed, and percentage of 355-ms or 500-ms lapses combined with false starts) between the laptop and the wrist-worn PVT with the backlight on were less than 4.5 %. Specifically, the median difference in reaction times was less than 10 ms. However, the standard deviation in most metrics using the wrist-worn PVT was twice that of the laptop. In a second experiment, we compared the wrist-worn and laptop PVTs with the same ISIs (1-4 s) in normal light conditions. The results suggest that PVT data can be collected reliably in the field using the wrist-worn device with the backlight on and an ISI of 2-10 s.
引用
收藏
页码:1792 / 1801
页数:10
相关论文
共 50 条
  • [21] Noninvasive validation of central and peripheral augmentation index estimated by a novel wrist-worn tonometer
    Garcia-Ortiz, Luis
    Recio-Rodriguez, Jose I.
    Agudo-Conde, Cristina
    Maderuelo-Fernandez, Jose A.
    Patino-Alonso, Maria C.
    de Cabo-Laso, Angela
    Rodriguez-Martin, Carmela
    Gonzalez-Sanchez, Jesus
    Rodriguez-Sanchez, Emiliano
    Gomez-Marcos, Manuel A.
    JOURNAL OF HYPERTENSION, 2018, 36 (11) : 2204 - 2214
  • [22] Validation of a Portable, Touch-Screen Psychomotor Vigilance Test
    Honn, Kimberly A.
    Riedy, Samantha M.
    Grant, Devon A.
    AEROSPACE MEDICINE AND HUMAN PERFORMANCE, 2015, 86 (05) : 428 - 434
  • [23] VALIDATION OF A MODIFIED BRIEF VERSION OF THE PSYCHOMOTOR VIGILANCE TEST (PVT)
    Basner, M.
    Mollicone, D. J.
    Dinges, D. F.
    SLEEP, 2011, 34 : A110 - A110
  • [24] Accuracy of wrist-worn activity trackers for measuring steps in patients after major abdominal surgery: A validation study
    Li, Zhi
    Feng, Weiyan
    Zhou, Lili
    Gong, Shu
    DIGITAL HEALTH, 2024, 10
  • [25] MEASURING FATIGUE FOLLOWING ACQUIRED BRAIN INJURY: A VALIDATION STUDY OF THE PSYCHOMOTOR VIGILANCE TEST
    Bruijel, Jessica
    Vermeeren, Annemiek
    Van Der Sluiszen, Nick N. J. J. M.
    Jongen, Stefan
    Stapert, Sven Z.
    Van Heugten, Caroline M.
    JOURNAL OF REHABILITATION MEDICINE, 2020, 52 (11)
  • [26] 3-min All-out Exercise Test for Running
    Pettitt, R. W.
    Jamnick, N.
    Clark, I. E.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2012, 33 (06) : 426 - 431
  • [27] Step Validation Of A Commercially-available Wrist-worn Accelerometer In Normal, Overweight, And Obese Adults
    Buman, Matthew P.
    Hekler, Eric B.
    Floegel, Theresa
    Pregonero, Alberto Florez
    Gutierrez, Monica
    Riley, Kaitlin
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 293 - 293
  • [28] Development and large-scale validation of the Watch Walk wrist-worn digital gait biomarkers
    Chan, Lloyd L. Y.
    Choi, Tiffany C. M.
    Lord, Stephen R.
    Brodie, Matthew A.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [29] Preliminary feasibility of a wrist-worn receiver to measure medication adherence via an ingestible radiofrequency sensor
    Goldfine, Charlotte E.
    Mohamed, Yassir
    Goodman, Georgia R.
    Albrechta, Hannah
    Hokayem, Joanne
    Mayer, Kenneth H.
    O'Cleirigh, Conall
    Lee, Jasper S.
    Alpert, Pamela
    Standley, Adam
    Carnes, T. Christopher
    Chai, Peter R.
    2023 IEEE 19TH INTERNATIONAL CONFERENCE ON BODY SENSOR NETWORKS, BSN, 2023,
  • [30] Avoiding involuntary sleep during civil air operations: Validation of a wrist-worn alertness device
    Wright, N
    Powell, D
    McGown, A
    Broadbent, E
    Loft, P
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 2005, 76 (09): : 847 - 856