共 22 条
Line-to-line short-circuit-based finite-element performance and parameter predictions of large hydrogenerators
被引:28
|作者:
Wamkeue, R
[1
]
Kamwa, I
Chacha, M
机构:
[1] UQAT, Rouyn Norando, PQ J9X 5E4, Canada
[2] Hydro Quebec IREQ, Power Syst Anal Operat & Control, Varennes, PQ J3X 1S1, Canada
[3] Ryerson Polytech Univ, Toronto, ON M5B 2K3, Canada
关键词:
performance and parameter predictions;
synchronous machines;
transient electromagnetic analysis;
D O I:
10.1109/TEC.2003.815672
中图分类号:
TE [石油、天然气工业];
TK [能源与动力工程];
学科分类号:
0807 ;
0820 ;
摘要:
A two-dimensional (2-D), time-stepped finite-element (FE) method is used to model and successfully replicate saturated line-to-line and three-phase short-circuit test responses recorded on a 40-pole 13.75-MVA hydrogenerator at Hydro-Quebec's Rapides-des-Quinze generating station. Three levels of line-to-line and sudden three-phase short-circuit tests (0.13, 0.25, and 0.48 p.u.) are simulated numerically using the FE-based model. While symmetrical faults are only used for parameter determination, the computed line-to-line waveforms are thoroughly compared to real data, with special attention given to field current responses. According to IEEE Std.-115-1995, the d-axis dynamic reactances and time-constants are computed from three-phase short-circuit tests while the negative-sequence reactance is derived from the line-to-line short-circuit test resulting in a rated armature current. The obtained simulated tests responses and parameter values, from both symmetrical and asymmetrical faults, support the effectiveness of the proposed FE-based model in incorporating the saturation phenomenon, large number of poles, and detailed damper representation to achieve an accurate dynamic performance assessment together with negative-sequence reactance and dynamic constants prediction.
引用
收藏
页码:370 / 378
页数:9
相关论文