ZnO@graphene nanocomposite modified electrode for sensitive and simultaneous detection of Cd (II) and Pb (II)

被引:62
|
作者
Yukird, Jutiporn [1 ]
Kongsittikul, Pongsakorn [2 ]
Qin, Jiaqian [3 ]
Chailapakul, Orawon [4 ]
Rodthongkum, Nadnudda [3 ,5 ]
机构
[1] Chulalongkorn Univ, Grad Sch, Nanosci & Technol Interdisciplinary Program, Phayathai Rd, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Fac Sci, Petrochem & Polymer Sci, Phayathai Rd, Bangkok 10330, Thailand
[3] Chulalongkorn Univ, Met & Mat Sci Res Inst, Soi Chula 12,Phayathai Rd, Bangkok 10330, Thailand
[4] Chulalongkorn Univ, Fac Sci, Dept Chem, Electrochem & Opt Spect Res Unit, Phayathai Rd, Bangkok 10330, Thailand
[5] Chulalongkorn Univ, Nanotec CU Ctr Excellent Food & Agr, Phayathai Rd, Bangkok 10330, Thailand
关键词
Zinc oxide nanorod; Graphene; Nanocomposite; Electrochemical sensor; Cadmium; Lead; CARBON-PASTE ELECTRODE; HEAVY-METAL IONS; SIMULTANEOUS ELECTROCHEMICAL DETERMINATION; VOLTAMMETRIC DETECTION; ENHANCED SENSITIVITY; HYDROTHERMAL GROWTH; OXIDE COMPOSITES; TRACE LEAD; CADMIUM; PB(II);
D O I
10.1016/j.synthmet.2018.09.012
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Zinc Oxide (ZnO) nanorods were synthesized by using zinc acetate as a precursor via thermal decomposition method and then used to prepare ZnO@G nanocomposite by facile room-temperature approach using a colloidal coagulation effect. The as prepared ZnO@G nanocomposite was applied to modify the working electrode surface in an electrochemical sensor of Cd2+ and Pb2+ for the first time. The morphologies of ZnO and ZnO@G nano composite were characterized by transmission electron microscopy, that exhibits the nanorod shape with an average diameter of 89 +/- 18 nm, uniformly dispersed and intercalated between each G layer. Furthermore, the important factors affecting on the sensor sensitivity, including ZnO@G ratio, ZnO@G concentration, Bi3+ concentration and electrochemical parameters were systematically investigated using square-wave anodic stripping voltarnmetry. Under the optimal conditions, a linear range was found to be 10-200 mu g L-1 and the detection limits were 0.6 and 0.8 mu g L-1 for Cd2+ and Pb2+, respectively. Eventually, it was successfully used for the simultaneous detection of Cd2+ and Pb2+ in real wastewater samples and the results corresponded well with a standard inductively coupled plasma-optical emission spectroscopy.
引用
收藏
页码:251 / 259
页数:9
相关论文
共 50 条
  • [21] Ag metal organic frameworks nanocomposite modified electrode for simultaneous electrochemical detection of copper (II) and lead (II)
    Dayoung Kwon
    Jongsung Kim
    Journal of Applied Electrochemistry, 2021, 51 : 1207 - 1216
  • [22] Simultaneous determination of Cd(II) and Pb(II) using electrode modified by FeAl2O4-AlOOH-reduced graphene oxide hybrids
    Fan Bai
    Qun Li
    Tao Yang
    Junhong Chen
    Xinmei Hou
    Ionics, 2019, 25 : 2351 - 2360
  • [23] Simultaneous determination of Cd(II) and Pb(II) using electrode modified by FeAl2O4-AlOOH-reduced graphene oxide hybrids
    Bai, Fan
    Li, Qun
    Yang, Tao
    Chen, Junhong
    Hou, Xinmei
    IONICS, 2019, 25 (05) : 2351 - 2360
  • [24] Reduced graphene oxide/ZnO nanocomposite modified electrode for the detection of tetracycline
    Ana Đurović
    Zorica Stojanović
    Zuzana Bytešníková
    Snežana Kravić
    Pavel Švec
    Jan Přibyl
    Lukáš Richtera
    Journal of Materials Science, 2022, 57 : 5533 - 5551
  • [25] Reduced graphene oxide/ZnO nanocomposite modified electrode for the detection of tetracycline
    Durovic, Ana
    Stojanovic, Zorica
    Bytesnikova, Zuzana
    Kravic, Snezana
    Svec, Pavel
    Pribyl, Jan
    Richtera, Lukas
    JOURNAL OF MATERIALS SCIENCE, 2022, 57 (09) : 5533 - 5551
  • [26] Simultaneous determination of Cd and Pb in the environment using a pencil graphite electrode modified with polyaniline/graphene oxide nanocomposite
    Pourbeyram, Sima
    Fathalipour, Soghra
    Rashidzadeh, Bahaaldin
    Firuzmand, Hananeh
    Rahimi, Behnaz
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2023, 9 (12) : 3355 - 3365
  • [27] Graphene oxide-ZnO nanocomposite modified electrode for the detection of phenol
    Arfin, Tanvir
    Rangari, Stephy N.
    ANALYTICAL METHODS, 2018, 10 (03) : 347 - 358
  • [28] Simultaneous determination of trace Pb(II), Cd(II), and Zn(II) using an integrated three-electrode modified with bismuth film
    Li, Hui
    Zhao, Jie
    Zhao, Shifan
    Cui, Guofeng
    MICROCHEMICAL JOURNAL, 2021, 168
  • [29] Bismuth Subcarbonate Decorated Reduced Graphene Oxide Nanocomposite for the Sensitive Stripping Voltammetry Analysis of Pb(II) and Cd(II) in Water
    Zhao, Guo
    Sedki, Mohammed
    Ma, Shengcun
    Villarreal, Claudia
    Mulchandani, Ashok
    Jassby, David
    SENSORS, 2020, 20 (21) : 1 - 17
  • [30] Stainless steel electrode for simultaneous stripping analysis of Cd(II), Pb(II), Cu(II) and Hg(II)
    Kitte, Shimeles Addisu
    Li, Suping
    Nsabimana, Anaclet
    Gao, Wenyue
    Lai, Jianping
    Liu, Zhongyuan
    Xu, Guobao
    TALANTA, 2019, 191 : 485 - 490