Diagnostic and Clinical Predictive Value of Optic Nerve Sheath Diameter Measurement in Children with Increased Intracranial Pressure

被引:2
|
作者
Kendir, Ozlem Tolu [1 ,4 ]
Yilmaz, Hayri Levent [1 ]
Balli, Huseyin Tugsan [2 ]
Gokay, Sinem Sari [1 ]
Unal, Ilker [3 ]
Ozkaya, Ahmet Kagan [1 ,5 ]
机构
[1] Cukurova Univ, Dept Pediat, Emergency Care Unit, Balcali Hosp, Adana, Turkey
[2] Cukurova Univ, Balcali Hosp, Dept Radiol, Adana, Turkey
[3] Cukurova Univ, Dept Biostat, Balcali Hosp, Applicat & Res Ctr, Adana, Turkey
[4] Akdeniz Univ, Dept Pediat, Emergency Care Unit, Antalya, Turkey
[5] Karadeniz Tech Univ, Dept Pediat, Emergency Care Unit, Trabzon, Turkey
关键词
Optic nerve sheath measurement; increased intracranial pressure; cerebral edema; CARE OCULAR ULTRASOUND; SONOGRAPHIC MEASUREMENT; IDENTIFICATION; TOMOGRAPHY; WINDOW; EDEMA; ONSD;
D O I
10.14744/etd.2021.43809
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: In this study, we aimed to determine the diagnostic and clinical predictive value of optic nerve sheath diameter (ONSD) measurement in pediatric patients suspected of increased intracranial pressure (IICP) by comparing sonographic ONSD values with radiological parameters and controls. Materials and Methods: In total, 57 pediatric patients with suspected IICP who underwent computed tomography (CT) scans were included in this prospective, observational study; meanwhile, 35 patients were included as controls. Measurements were obtained while the patients were in supine position with their eyes closed, and transbulbar images of both eyes were obtained via a 6-15 MHz linear probe. The CT scans were assessed by a radiologist blinded to sonographic measurements. Glasgow coma scale of patients, service where they were followed, clinical results, CT, and ONSD values were assessed in this study. Results: In the patient group, 26 of the patients were girls (35.4%), and the mean age was 138 +/- 56 months (min-max: 82-194 months). Meanwhile, in the control group, 18 of the patients were girls (40.9%), and mean age was 151 +/- 45 months (min-max: 106-196 months). As per our findings, 31 patients (54.4%) presented with high-energy trauma. Mean ONSD was 0.5 +/- 0.07 cm in the patient group, whereas it was 0.3 +/- 0.02 cm in the control group (p=0.008). It was 0.55 +/- 0.07 cm in patients with cerebral edema (CE) on CT scan (p=0.013). Based on the presence of CE as detected via CT scan, cut-off value for measurement was determined to be 0.49 cm, with 83.33% sensitivity and 68.42% specificity (AUC: 0.784). Conclusion: Optic nerve sheath measurement can be utilized to immediately support diagnosis and predict follow-up in the assessment of pediatric patients with ICP elevation.
引用
收藏
页码:554 / 559
页数:6
相关论文
共 50 条
  • [41] Noninvasive and quantitative intracranial pressure estimation using ultrasonographic measurement of optic nerve sheath diameter
    Wang, Li-juan
    Yao, Yan
    Feng, Liang-shu
    Wang, Yu-zhi
    Zheng, Nan-nan
    Feng, Jia-chun
    Xing, Ying-qi
    SCIENTIFIC REPORTS, 2017, 7
  • [42] Measuring Optic Nerve Sheath Diameter as a Proxy for Intracranial Pressure Reply
    Wang, Li-juan
    Chen, Hong-xiu
    Xing, Ying-qi
    JAMA OPHTHALMOLOGY, 2018, 136 (11) : 1311 - 1312
  • [43] ULTRASONOGRAPHY OF OPTIC NERVE SHEATH DIAMETER (ONSD) FOR RAISED INTRACRANIAL PRESSURE
    Siddiqui, Naveed Ur Rehman
    CRITICAL CARE MEDICINE, 2018, 46 (01) : 397 - 397
  • [44] Optic Nerve Sheath Diameter Assessment in Patients with Intracranial Pressure Monitoring
    Kavi, Tapan
    Gupta, Anuj
    Hunter, Krystal
    Schreiber, Craig
    Shaikh, Hamza
    Turtz, Alan R.
    CUREUS, 2018, 10 (11):
  • [45] Keep an Eye on the Intracranial Pressure, Thanks to the Optic Nerve Sheath Diameter
    Weinmann, Alexandre Vagh
    Beaucreux, Charlotte
    Kearns, Kevin
    Dubost, Clement
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2018, 22 (06) : 460 - 462
  • [46] Use of the sonographic diameter of optic nerve sheath to estimate intracranial pressure
    Amini, Afshin
    Kariman, Hamid
    Dolatabadi, Ali Arhami
    Hatamabadi, Hamid Reza
    Derakhshanfar, Hojjat
    Mansouri, Behnam
    Safari, Saeed
    Eqtesadi, Razie
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (01): : 236 - 239
  • [47] Optic nerve sheath diameter ultrasonography for elevated intracranial pressure detection
    Wang Li-Juan
    Chen Hong-Xiu
    Chen Ying
    Yu Ze-Yang
    Xing Ying-Qi
    ANNALS OF CLINICAL AND TRANSLATIONAL NEUROLOGY, 2020, 7 (05): : 865 - 868
  • [48] Value of Ultrasonographic Optic Nerve Sheath Diameter in Assessing Increased Intracranial Pressure in Patients With Moderate to Severe Traumatic Brain Injury
    A Abdalla
    BN Beshey
    AM Abougabal
    KM Elzahaby
    Intensive Care Medicine Experimental, 3 (Suppl 1)
  • [49] Letter: Noninvasive Transorbital Assessment of the Optic Nerve Sheath in Children: Relationship Between Optic Nerve Sheath Diameter, Deformability Index, and Intracranial Pressure
    De Bernardo, Maddalena
    Vitiello, Livio
    Rosa, Nicola
    OPERATIVE NEUROSURGERY, 2020, 18 (01) : E27 - E28
  • [50] In Reply: Noninvasive Transorbital Assessment of the Optic Nerve Sheath in Children: Relationship Between Optic Nerve Sheath Diameter, Deformability Index, and Intracranial Pressure
    Padayachy, Llewellyn
    Brekken, Reidar
    Selbekk, Tormod
    OPERATIVE NEUROSURGERY, 2020, 18 (01) : E29 - E29