Comparison of the clinical and radiological outcomes of arthroscopic transosseous and transosseous-equivalent double-row rotator cuff repair techniques

被引:5
|
作者
Firat, Ahmet [1 ]
Aydin, Mustafa [2 ]
Tecimel, Osman [1 ]
Ocguder, Ali [1 ]
Sanisoglu, Yavuz [3 ]
Ugurlu, Mahmut [1 ]
机构
[1] Ankara City Hosp, Dept Orthoped, Ankara, Turkey
[2] Gulhane Training & Res Hosp, Dept Orthoped, Ankara, Turkey
[3] Yildirim Beyazit Univ, Dept Biostat, Ataturk Training & Res Hosp, Ankara, Turkey
关键词
Rotator cuff; Arthroscopy; Transosseous; Suture bridge; Repair; SUPRASPINATUS TENDON TEARS; SUTURE ANCHOR TECHNIQUE; MODIFIED MASON-ALLEN; SINGLE-ROW; BIOMECHANICAL EVALUATION; FIXATION; RECONSTRUCTION; ADVANTAGES; STRENGTH; ATROPHY;
D O I
10.5152/j.aott.2020.02.37
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: This study compared the clinical and radiological results of the arthroscopic transosseous (ATO) and transosseous-equivalent (TOE) double-row rotator cuff repair techniques. Methods: Prospective data collected from patients treated with ATO (32 women and 7 men, mean age: 57.03 +/- 6.39 years) and TOE (36 women and 8 men; mean age: 57.86 +/- 7.81 years) techniques were retrospectively evaluated. The visual analog scale score, Constant score, and Oxford shoulder score were used to assess the clinical results. Anchor pullout on standard antcroposterior shoulder radiographs and rotator cuff re-tear on magnetic resonance images were examined at the final follow-up to evaluate the radiological results. Rotator cuff re-tears were graded as per the classification system described by Sugaya et al. Results: The mean follow-up duration was 33.3 +/- 11.8 months. No difference was observed in the demographic data of the two groups. Significant improvement was observed in the postoperative shoulder scores of the groups; however, no difference was observed between the groups. Re-tear was detected in 10 patients of the TOE group and 9 patients of the ATO group. Age, tear size, and retraction level could cause re-tear. Conclusion: In the treatment of rotator cuff tears, the ATO and TOE techniques may achieve considerable improvements in shoulder functions in the short term.
引用
收藏
页码:178 / 185
页数:8
相关论文
共 50 条
  • [41] Factors influencing operative time in arthroscopic rotator cuff repair: a comparison of knotless single -row vs. transosseous equivalent dual -row techniques
    Boyd, Jason A.
    Karas, Spero G.
    Urchek, Ryan J.
    Farley, Kevin X.
    Anastasio, Albert T.
    Gottschalk, Michael B.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (07) : S48 - S52
  • [42] Biomechanical Comparison of Transosseous Knotless Rotator Cuff Repair Versus Transosseous Equivalent Repair: Half The Anchors With Equivalent Biomechanics?
    Tashjian, Robert Z.
    Hoy, Robert W.
    Helgerson, Joel R.
    Guss, Andrew D.
    Henninger, Heath B.
    Burks, Robert T.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2018, 34 (01): : 58 - 63
  • [43] Technique for a Novel Arthroscopic Transosseous Rotator Cuff Repair
    Castagna, Alessandro
    Gumina, Stefano
    Garofalo, Raffaele
    Mantovani, Matteo
    Kany, Jean
    Chillemi, Claudio
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2019, 20 (01): : 12 - 18
  • [44] Arthroscopic Transosseous Rotator Cuff Repair: Technical Note, Outcomes, and Complications
    Black, Eric M.
    Lin, Albert
    Srikumaran, Uma
    Jain, Nitin
    Freehill, Michael T.
    ORTHOPEDICS, 2015, 38 (05) : E352 - E358
  • [45] Quadriceps Tenon Rupture: A Biomechanical Comparison of Transosseous Equivalent Double-Row Suture Anchor Versus Transosseous Tunnel Repair
    Hart, Nathan D.
    Wallace, Matthew K.
    Scovell, J. Field
    Krupp, Ryan J.
    Cook, Chad
    Wyland, Douglas J.
    JOURNAL OF KNEE SURGERY, 2012, 25 (04) : 335 - 339
  • [46] Outcomes following arthroscopic transosseous equivalent suture bridge double row rotator cuff repair: a prospective study and short-term results
    Imam, Mohamed Abdelnabi
    Abdelkafy, Ashraf
    SICOT-J, 2016, 2
  • [47] Arthroscopic Transosseous Rotator Cuff Repair: First Experience
    Hudecek, F.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2022, 89 (03) : 181 - 187
  • [48] Comparing Conventional Double-Row With Transosseous Equivalent Suture Bridge Fixation in Arthroscopic Rotator Cuff Repairs: A Multicenter Retrospective Cohort Study
    Antoniades, Stephanie
    Walsh, Kellen
    Pollock, J. W.
    Sabri, Elham
    Macdonald, Peter
    Bouliane, Martin
    Mcilquham, Katie
    Hodgdon, Taryn
    Lapner, Peter
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2025, 13 (01)
  • [49] Arthroscopic Rotator Cuff Repair-Transosseous Equivalents
    Heard, Wendell
    Romeo, Anthony
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2012, 20 (03) : 220 - 223
  • [50] Evaluating transosseous anchorless repair for arthroscopic rotator cuff surgery: a comparative study with double row anchor repair
    Sundar, Shyam
    Sane, Rohit Mahesh
    Sundaramoorthy, Raghulraj
    Ashraf, Munis
    Rajan, David, V
    CLINICS IN SHOULDER AND ELBOW, 2025, 28 (01): : 23 - 30