Maximizing PV hosting capacity of distribution feeder microgrid

被引:22
|
作者
Lee, J. [1 ]
Berard, Jean-Philippe [2 ]
Razeghi, G. [1 ]
Samuelsen, S. [1 ]
机构
[1] Univ Calif Irvine, Adv Power & Energy Program, Irvine, CA 92697 USA
[2] OPAL RT Technol, Montreal, PQ, Canada
关键词
Distributed energy resources; Distribution management; Controller; GHG reduction; Substation automation; Feeder microgrid; BATTERY ENERGY-STORAGE; LOW-VOLTAGE NETWORKS; SYSTEMS; INTEGRATION; PENETRATION; PROFILE;
D O I
10.1016/j.apenergy.2019.114400
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To meet energy and environmental goals and challenging reliability and resiliency targets, the electric grid is transitioning from solely central generation to the inclusion of distributed energy resources (DERs). With a high penetration of DERs on primary circuits (feeders), utility substation communication, automation, and control must adopt to this new paradigm. In principle, utility substations can transition to and operate the feeder circuits in an islanded mode, effectively as Distribution Feeder Microgrids. This creates the need for research to address the challenges associated with integrating and managing significant deployment of DERs on circuits served by distribution substations. In response, this study addresses substation control to manage circuits emanating from utility substations as a microgrid. To this end, a model for substation automatic control using a Generic Microgrid Controller compliant with the IEEE 2030.7 standard was developed, and the role and impact of substation control to improve energy management, increase renewable penetration, and reduce greenhouse gas emissions were evaluated. The detailed digital simulation model developed encompassed two 12 kV distribution circuits emanating from a utility distribution substation. Individual homes were modeled and results verified using field data collected from a previous study. Various scenarios were simulated in order to determine PV hosting capability of the circuits equipped with a controller at the substation and with three energy storage configurations: (1) A residential energy storage unit (RESU) where all customers own a battery energy storage behind the meter, (2) a community energy storage (CES) unit where a utility-owned battery energy storage is deployed near each transformer, and (3) a circuit battery where a relatively large battery is deployed at the substation serving the entire feeder microgrid. Results show that substation automation and control can increase renewable penetration and reduce emissions without any necessary upgrades to the grid infrastructure. Moreover, the CES configuration was found to be a more economic approach for achieving high PV penetration and GHG reduction than residential storage, achieving a 660 mTCO(2eq) reduction per MWh of installed energy storage and overall 32% reduction in greenhouse gas emissions.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] On the Integrated PV Hosting Capacity of MV and LV Distribution Networks
    Ballanti, Andrea
    Ochoa, Luis F.
    2015 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES LATIN AMERICA (ISGT LATAM), 2015, : 366 - 370
  • [22] Determining maximum hosting capacity for PV systems in distribution grids
    Yuan, Jingyi
    Weng, Yang
    Tan, Chin-Woo
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 135
  • [23] Maximizing distribution network hosting capacity through optimal network reconfiguration
    Jakus, Damir
    Cadenovic, Rade
    Vasilj, Josip
    Sarajcev, Petar
    2019 16TH INTERNATIONAL CONFERENCE ON THE EUROPEAN ENERGY MARKET (EEM), 2019,
  • [24] Optimal SVC placement for Maximizing Photovoltaic Hosting Capacity in Distribution Network
    Xu, Xu
    Xu, Zhao
    Lyu, Xue
    Li, Jiayong
    IFAC PAPERSONLINE, 2018, 51 (28): : 356 - 361
  • [25] Maximizing Hosting Capacity of Distributed Generation by Network Reconfiguration in Distribution System
    Takenobu, Yuji
    Kawano, Shunsuke
    Hayashi, Yasuhiro
    Yasuda, Norihito
    Minato, Shin-ichi
    2016 POWER SYSTEMS COMPUTATION CONFERENCE (PSCC), 2016,
  • [26] Sensitivity Region-Based Optimization for Maximizing Renewable Generation Hosting Capacity of an Islanded Microgrid
    Liu, Daichen
    Zhang, Cuo
    Xu, Yan
    Dong, Zhaoyang
    Chi, Yuan
    IEEE TRANSACTIONS ON SMART GRID, 2023, 14 (04) : 2496 - 2507
  • [27] A data-driven approach for maximizing solar PV capacity at the distribution feeder level under existing operational paradigms
    Sward, Jeffrey A.
    Zhang, K. Max
    2019 IEEE POWER & ENERGY SOCIETY INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE (ISGT), 2019,
  • [28] dStudy on the Influence of Topology, Load Distribution and PV Installation Location on PV Hosting Capacity
    Lin, Zihan
    Chen, Chen
    2024 7TH INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY AND POWER ENGINEERING, REPE 2024, 2024, : 85 - 89
  • [29] Distributed PV Hosting Capacity Calculation of Distribution Network Based on PV Barycenter Theory
    Wei X.
    Wu J.
    Ding R.
    Shao Y.
    Wang Y.
    Zhang W.
    Dianwang Jishu/Power System Technology, 2023, 47 (11): : 4533 - 4544
  • [30] Probabilistic Analysis of PV Curtailment Impact on Distribution Circuit Hosting Capacity
    Kahrobaee, Salman
    Mehr, Vahid
    2020 47TH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2020, : 2210 - 2213