Artificial retinal vein model with semicircular cross-section for microcannulation

被引:0
|
作者
Kato, Ippei [1 ]
Mitsuishi, Mamoru [2 ]
Sugita, Naohiko [2 ]
Harada, Kanako [2 ]
Tanaka, Shinichi [2 ]
Noda, Yasuo [2 ]
Ueta, Takashi [2 ]
Arai, Fumihito [1 ]
机构
[1] Nagoya Univ, Dept Micronano Syst Engn, Chikusa Ku, Nagoya, Aichi 4648603, Japan
[2] Univ Tokyo, Bunkyo Ku, Tokyo 1138654, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper reports fabrication of retinal microvessels model for evaluation of microcannulation. Because microcannulation as a new treatment for retinal vein occlusion is difficult surgery operation, development and evaluation of microsurgical robot systems to assistant vitreoretinal surgery is needed. Evaluation of microcannulation needs a retinal microvessels model without individual difference. Therefore, we fabricated artificial microvessel models with the scale and the cross-sectional shape simulating the actual vascular by using the micro-nano-processing technology.
引用
收藏
页数:2
相关论文
共 50 条
  • [21] CROSS-SECTION SUM RULES IN STATIC MODEL
    NOGA, M
    NUCLEAR PHYSICS B, 1967, B 2 (05) : 532 - &
  • [22] CROSS-SECTION MODEL OF ECONOMIC GROWTH - COMMENT
    DEGRAUWE, P
    REVIEW OF ECONOMICS AND STATISTICS, 1972, 54 (04) : 466 - 467
  • [23] OPTICAL MODEL ANALYSIS OF REACTION CROSS-SECTION
    PASCUAL, R
    CARBONELL, FV
    ANALES DE LA REAL SOCIEDAD ESPANOLA DE FISICA Y QUIMICA SERIA A-FISICA, 1967, A 63 (7-8): : 229 - +
  • [24] MULTIPERIPHERAL MODEL WITH CONSTANT TOTAL CROSS-SECTION
    LEVIN, EM
    RYSKIN, MG
    PHYSICS LETTERS B, 1972, 41 B (05) : 626 - &
  • [25] Stress and strain concentrations in an elasto-plastic bar of circular cross-section with semicircular groove
    Hou, Jian
    Yang, Zheng
    ADVANCED MANUFACTURING TECHNOLOGY, PTS 1-4, 2012, 472-475 : 1388 - 1391
  • [26] SIMULATION OF THE MELT FRONT ADVANCEMENT IN INJECTION-MOLDED PLATE WITH A RIB OF SEMICIRCULAR CROSS-SECTION
    CHEN, SC
    HSU, KF
    HSU, KS
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 1995, 28 (01) : 121 - 129
  • [27] MAP OF RETINAL POSITION ONTO THE CROSS-SECTION OF THE OPTIC PATHWAY OF GOLDFISH
    BERNHARDT, R
    EASTER, SS
    JOURNAL OF COMPARATIVE NEUROLOGY, 1986, 254 (04) : 493 - 510
  • [28] Estimating Retinal Vessel Diameter Change from the Vessel Cross-Section
    Azemin, M. Z. Che
    Kumar, D. K.
    5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 655 - 658
  • [29] MEASUREMENT OF THE CROSS-SECTION IN WIRE ROLLING AND FACTORS MODIFYING THE CROSS-SECTION
    THIES, H
    NEUSCHUTZ, E
    REVUE DE METALLURGIE-CAHIERS D INFORMATIONS TECHNIQUES, 1980, 77 (02): : 175 - 182
  • [30] Retinal vessel model fabricated on a curved surface structure for a simulation of microcannulation
    Hayakawa T.
    Kato I.
    Arai F.
    Mitsuishi M.
    Sugita N.
    Harada K.
    Tanaka S.
    Noda Y.
    Ueta T.
    ROBOMECH Journal, 3 (1):