In this work, the exergy analysis of vapour compression-absorption two-stage refrigeration cycle has been performed. While NH3-H2O has been used as fluid pair in the absorption section, NH3 has been used in the vapour compression section. To improve the performance of the cycle, it is possible to reduce the total damage by focusing on the parts that cause high exergy damage. Therefore, the detailed exergy analysis has been made for different operating conditions (generator temperature, condenser temperature and intermediate pressure) of the cycle. The exergy destruction rates of each component were calculated and compared. As the generator temperature increases, the highest exergy destruction rates are seen in the generator. The generator exergy destruction rates increase with increasing condenser temperature. Also, the performance coefficient (COPcyclegen) and the exergy efficiency (epsilon) of the novel cycle have been investigated for different the intermediate pressures. The performance coefficient (COPcyclegen) increases as the intermediate pressure increases. Maximum value of the exergy efficiency is obtained at the intermediate pressure of 516.015 kPa. With this cycle, it is possible to refrigerate down by using alternative energy sources. Also, the refrigeration system is environmentally friendly because environmentally safe fluids are used in this cycle.
引用
收藏
页码:210 / 221
页数:12
相关论文
共 50 条
  • [41] Thermodynamic performance analysis of a vapor compression-absorption cascaded refrigeration system
    Jain, Vaibhav
    Kachhwaha, S. S.
    Sachdeva, Gulshan
    ENERGY CONVERSION AND MANAGEMENT, 2013, 75 : 685 - 700
  • [42] A general methodology for energy comparison of intermediate configurations in two-stage vapour compression refrigeration systems
    Torrella, E.
    Larumbe, J. A.
    Cabello, R.
    Llopis, R.
    Sanchez, D.
    ENERGY, 2011, 36 (07) : 4119 - 4124
  • [43] Comprehensive performance analysis of cascade refrigeration system with two-stage compression for industrial refrigeration
    Sun, Zhili
    Wang, Yi 'an
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 39
  • [44] Comprehensive performance analysis of cascade refrigeration system with two-stage compression for industrial refrigeration
    Sun, Zhili
    Wang, Yi'An
    Case Studies in Thermal Engineering, 2022, 39
  • [45] Thermodynamic Modelling and Parametric Study of a Two Stage Compression-Absorption Refrigeration System for Ice Cream Hardening Plant
    Patel, Bhavesh
    Kachhwaha, Surendra Singh
    Modi, Bhaumik
    INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENT IN AIR CONDITIONING AND REFRIGERATION, RAAR 2016, 2017, 109 : 190 - 202
  • [46] Exergy analysis of vortex tube expansion vapour compression refrigeration system
    Sarkar, Jahar
    INTERNATIONAL JOURNAL OF EXERGY, 2013, 13 (04) : 431 - 446
  • [47] Comparative exergy and energy analyses of compression-absorption cascade refrigeration cycles with varied configurations and ejector implementations
    Bahrami, Hamid-Reza
    Fazli, Samane
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2024,
  • [48] Thermodynamic analysis of CO2 transcritical two-stage compression refrigeration cycle systems with expanders
    Liu S.
    Sun Z.
    Li H.
    Dai B.
    Chen Y.
    Sun, Zhili (sunzhili@tjcu.edu.cn), 1600, Taylor and Francis Asia Pacific (24): : 70 - 77
  • [49] A Study on an Absorption Refrigeration Cycle by Exergy Analysis Approach
    Mohtaram, Soheil
    Chen, Wen
    Lin, Ji
    2018 9TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2018, 182
  • [50] Thermodynamic analysis of CO2 trans-critical two-stage compression refrigeration cycle
    Key Laboratory of Condition Monitoring and Control of Power Plant Equipment, North China Electric Power University, Baoding 071003, China
    Huagong Xuebao, 2008, 12 (2985-2989):