Lead isotope ratios determined by ICP-MS: Investigation of anthropogenic lead in seawater and sediment from the Gulf of Carpentaria, Australia

被引:41
|
作者
Munksgaard, NC [1 ]
Batterham, GJ [1 ]
Parry, DL [1 ]
机构
[1] No Terr Univ, Sch Math & Phys Sci, Darwin, NT 0909, Australia
基金
澳大利亚研究理事会;
关键词
lead isotopes; ICP-MS; seawater; sediment; monitoring;
D O I
10.1016/S0025-326X(98)00011-3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Lead isotope ratios and concentrations have been measured in seawater and marine sediment by Inductively Coupled Plasma Mass Spectrometry (ICP-MS). For seawater, solvent extraction pre-concentration and the use of a micro-concentric nebulizer allowed 1 mi of concentrate to be measured for several minutes to achieve precisions in the range 0.5-1.2% relative standard deviation for Pb-208/Pb-206 and Pb-207/Pb-206. The environmental dispersion of trace amounts of anthropogenic Pb produced distinctive Pb isotope ratio changes in seawater and marine sediments in the immediate vicinity of a Pb-Zn concentrate shipping facility. Concentrate was found to have Pb-208/Pb-206 ratios in the range 2.21-2.25, whereas environmental background Pb-208/Pb-206 ratios were: filtered (<0.45 mu m) seawater, 2.13-2.15; unfiltered seawater, 2.06-2.10; sediment, 2.06-2.09, The combined Pb isotope ratio and concentration measurements by ICP-MS have provided a sensitive and cost effective monitoring tool allowing an unambiguous assessment of the source of Pb, (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:527 / 534
页数:8
相关论文
共 50 条
  • [31] ICP-MS measurements of lead isotopic ratios in soils heavily contaminated by lead smelting:: tracing the sources of pollution
    Ettler, V
    Mihaljevic, M
    Komárek, M
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (02) : 311 - 317
  • [32] Trace lead measurement and on-line removal of matrix interference in seawater by isotope dilution coupled with flow injection and ICP-MS
    Huang, ZY
    Chen, FR
    Zhuang, ZX
    Wang, XR
    Lee, FSC
    ANALYTICA CHIMICA ACTA, 2004, 508 (02) : 239 - 245
  • [33] Lead isotope ratio measurements by ICP-MS: Accuracy, precision, and long-term drift
    Halicz, L
    Erel, Y
    Veron, A
    ATOMIC SPECTROSCOPY, 1996, 17 (05) : 186 - 189
  • [34] CAIS correction for blood matrix effect on determination of lead concentration and isotope ratio by ICP-MS
    Zeng Jing
    Wang Xiao-yan
    Liu Hu-sheng
    Dun Zhe
    Zhai Lei
    Wang Jing-yu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27 (02) : 374 - 377
  • [35] Investigation of Sr isotope ratios in prehistoric human bones and teeth using laser ablation ICP-MS and ICP-MS after Rb/Sr separation
    Prohaska, Thomas
    Latkoczy, Christopher
    Schultheis, Gerald
    Teschler-Nicola, Maria
    Stingeder, Gerhard
    Journal of Analytical Atomic Spectrometry, 2002, 17 (08): : 887 - 891
  • [36] Investigation of Sr isotope ratios in prehistoric human bones and teeth using laser ablation ICP-MS and ICP-MS after Rb/Sr separation
    Prohaska, T
    Latkoczy, C
    Schultheis, G
    Teschler-Nicola, M
    Stingeder, G
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (08) : 887 - 891
  • [37] A method for increasing the precision of isotope ratio analysis on a Quadrupole ICP-MS based on measurements of lead and strontium
    Dronov, Michail
    Schram, Juergen
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (11) : 1796 - 1803
  • [38] The determination of lead isotope ratios by multiple collector ICP-MS: A case study of Early Bronze Age artefacts and their possible relation with ore deposits of the Erzgebirge
    Niederschlag, E
    Pernicka, E
    Seifert, T
    Bartelheim, M
    ARCHAEOMETRY, 2003, 45 : 61 - 100
  • [39] LEAD ISOTOPE ANALYSIS AND CHEMICAL CHARACTERIZATION OF METALLIC RESIDUES OF AN EARLY BRONZE AGE CRUCIBLE FROM GOLTEPE: USING ICP-MS
    Lehner, Joseph W.
    Yener, Aslihan
    Burton, James
    TUBA-AR-TURKISH ACADEMY OF SCIENCES JOURNAL OF ARCHAEOLOGY, 2009, 12 : 165 - 174
  • [40] Determination of the Concentration and Isotope Ratio of Trace Lead in Lake Mashu by Solid-phase Extraction/ICP-MS
    Azumi, Suzuka
    Wada, Akari
    Sakagami, Hirotoshi
    Minami, Hirotsugu
    Fukazawa, Tatsuya
    Igarashi, Seiki
    Tanaka, Atsushi
    Takeuchi, Akinori
    Oyagi, Hideo
    Jin, Kazuo
    BUNSEKI KAGAKU, 2019, 68 (11) : 877 - 883