New VMAT non-coplanar solutions for mono-isocentric radiosurgery of multiple brain metastases

被引:0
|
作者
Kuijper, I. [1 ]
van Duijvenvoorde, P. [1 ]
Kossen, R. [1 ]
Slotman, B. J. [1 ]
Cuijpers, J. [1 ]
机构
[1] Amsterdam UMC, Radiotherapy, Amsterdam, Netherlands
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
OC-0643
引用
收藏
页码:S510 / S512
页数:4
相关论文
共 50 条
  • [31] The potential of an optical surface tracking system in non-coplanar single isocenter treatments of multiple brain metastases
    Swinnen, Ans C. C.
    Ollers, Michel C.
    Ong, Chin Loon
    Verhaegen, Frank
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (06): : 63 - 72
  • [32] Cost-effectiveness of Linac-based single-isocenter non-coplanar technique (HyperArcTM) for brain metastases radiosurgery
    Filippo Alongi
    Alba Fiorentino
    Ruggero Ruggieri
    Francesco Ricchetti
    Patrick Kupelian
    Clinical & Experimental Metastasis, 2018, 35 : 601 - 603
  • [33] Cost-effectiveness of Linac-based single-isocenter non-coplanar technique (HyperArcTM) for brain metastases radiosurgery
    Alongi, Filippo
    Fiorentino, Alba
    Ruggieri, Ruggero
    Ricchetti, Francesco
    Kupelian, Patrick
    CLINICAL & EXPERIMENTAL METASTASIS, 2018, 35 (07) : 601 - 603
  • [34] VMAT versus CyberKnife MLC non-isocentric planning for brain metastases stereotactic radiotherapy
    Felefly, T.
    Martinetti, F.
    Maroun, P.
    Marsolet, F.
    Huertas, A.
    Canova, C. H.
    Chargari, C.
    Escande, A.
    Dhermain, F.
    Lefkopoulos, D.
    Deutsch, E.
    Tafo, A. Guemnie
    Louvel, G.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1047 - S1048
  • [35] Comparison of Two Mono-Isocenter Techniques with Multiple Non-Coplanar Arcs for Linac Based SRS of Multiple Brain Lesions
    Ruggieri, R.
    Naccarato, S.
    Ricchetti, F.
    Mazzola, R.
    Gregucci, F.
    Figlia, V.
    Fiorentino, A.
    Corradini, S.
    Alongi, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E516 - E517
  • [36] Dosimetric comparison between dual-isocentric dynamic conformal arc therapy and mono-isocentric volumetric-modulated arc therapy for two large brain metastases
    Uto, Megumi
    Mizowaki, Takashi
    Ogura, Kengo
    Mukumoto, Nobutaka
    Katagiri, Tomohiro
    Takehana, Keiichi
    Hiraoka, Masahiro
    JOURNAL OF RADIATION RESEARCH, 2018, 59 (06) : 774 - 781
  • [37] Feasibility Study of Stereotactic Radiosurgery Using a Non-Commercial VMAT Treatment Planning System with a Non-Coplanar Delivery Technique
    Song, Y.
    Mueller, B.
    Obcemea, C.
    Burman, C.
    Mychalczak, B.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [38] Redefining the possible: planning multiple complex head lesions using non-coplanar VMAT arcs
    Guy, V.
    Sims, R.
    Falkov, A.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S980 - S980
  • [39] Model-based VMAT optimization: The future of radiosurgery for multiple brain metastases?
    Todorovic, Manuel
    Grohmann, Maximilian
    Petersen, Cordula
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3669 - S3672
  • [40] HyperArc VMAT planning for single and multiple brain metastases stereotactic radiosurgery: a new treatment planning approach
    Ohira, Shingo
    Ueda, Yoshihiro
    Akino, Yuichi
    Hashimoto, Misaki
    Masaoka, Akira
    Hirata, Takero
    Miyazaki, Masayoshi
    Koizumi, Masahiko
    Teshima, Teruki
    RADIATION ONCOLOGY, 2018, 13