Definitive Drug and Metabolite Screening in Urine by UPLC-MS-MS Using a Novel Calibration Technique

被引:9
|
作者
Rosano, Thomas G. [1 ,2 ]
Ohouo, Patrice Y. [2 ]
LeQue, John J. [2 ]
Freeto, Scott M. [3 ]
Wood, Michelle [4 ]
机构
[1] Albany Med Ctr Hosp & Coll, Dept Pathol & Lab Med, Forens Toxicol Lab, 43 New Scotland Ave, Albany, NY 12208 USA
[2] Ctr Med Sci, Natl Toxicol Ctr, Clin & Forens Toxicol Lab, 150 New Scotland Ave, Albany, NY 12208 USA
[3] Waters Corp, Cummings Ctr 100, Suite 407N, Beverly, MA USA
[4] Waters Corp, Hlth Sci Org, Altrincham Rd, Wilmslow, Cheshire, England
关键词
TANDEM MASS-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; TIME-OF-FLIGHT; LABELED INTERNAL STANDARD; LC-MS/MS; WHOLE-BLOOD; ABUSE; VALIDATION; MATRIX; TOXICOLOGY;
D O I
10.1093/jat/bkw050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Drug screening is an essential analytical tool for detection of therapeutic, illicit and emerging drug use. Presumptive immunoassay screening is widely used, while initial definitive testing by chromatography-coupled mass spectrometry is hampered due to complex pre-analysis steps, long chromatography time and matrix effects. The aim of this study is to develop and validate a definitive test for rapid and threshold accurate screening of 33 drugs or metabolites (analytes) in urine. Sample preparation in a 96-well plate format involves rapid glucuronidase hydrolysis followed by dilution, filtration and ultra-performance liquid chromatography-MS-MS analysis. Chromatographic separation, on an ACQUITY UPLCA (R) BEH phenyl column is optimized for a 3-min MS-MS ion acquisition. Matrix effect was normalized by an innovative technique called threshold accurate calibration employing an additional analysis with an analyte spike as an internal standard undergoing the same matrix effect as an analyte in a drug-positive donor specimen. Accuracy and precision, at above and below threshold concentrations, were determined by replicate analysis of control urine pools containing 50, 75, 125 and 150% of threshold concentrations. Accuracy and selectivity were further demonstrated by concordant findings in proficiency and confirmatory testing. The study shows the applicability of definitive testing as an alternative to immunoassay screening and demonstrates a new approach to normalization of matrix effect.
引用
收藏
页码:628 / 638
页数:11
相关论文
共 50 条
  • [41] Determination of ω-6 and ω-3 PUFA metabolites in human urine samples using UPLC/MS/MS
    Sasaki, Ai
    Fukuda, Hayato
    Shiida, Narumi
    Tanaka, Nobuaki
    Furugen, Ayako
    Ogura, Jiro
    Shuto, Satoshi
    Mano, Nariyasu
    Yamaguchi, Hiroaki
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (06) : 1625 - 1639
  • [42] Simultaneous Extraction and Quantification of Morphine-related Compounds in Plasma Using Mixed-mode SPE and UPLC-MS-MS
    Yin, Zhe
    Fountain, Kenneth J.
    Chambers, Erin E.
    Diehi, Diane M.
    LC GC EUROPE, 2009, : 20 - 20
  • [43] Quantification of 16 QT-prolonging Drugs and Metabolites in Human Postmortem Blood and Cardiac Tissue Using UPLC-MS-MS
    Mikkelsen, Christian R.
    Jornil, Jakob R.
    Andersen, Ljubica V.
    Banner, Jytte
    Hasselstrom, Jorgen B.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2016, 40 (04) : 286 - 293
  • [44] Simultaneous Extraction and Quantitative of Morphine-Related Compounds in Plasma Using Miked-Mode SPE and UPLC-MS-MS
    Yin, Zhe
    Fountain, Kenneth J.
    Chambers, Erin E.
    Diehl, Diane M.
    LC GC NORTH AMERICA, 2009, : 22 - 22
  • [45] The utility of in vitro screening for the assessment of electrophilic metabolite formation early in drug discovery using HPLC-MS/MS
    Grotz, DE
    Clarke, NA
    Cox, KA
    IDENTIFICATION AND QUANTIFICATION OF DRUGS, METABOLITES AND METABOLIZING ENZYMES BY LC-MS, 2005, 6 : 159 - 182
  • [46] Rapid screening of LC-MS/MS data to identify drug metabolites using meteor metabolite prediction software
    Firth, John W.
    Boyling, Lee
    Shackleton, Gareth L.
    Ives, Sian
    DRUG METABOLISM REVIEWS, 2009, 41 : 117 - 117
  • [47] A Fast, Sensitive and Validated Technique for Eurycomanone and Cordycepin Quantitation using UPLC‒MS/MS
    Lee Suan Chua
    Norliza Abdul Latiff
    Ismail Ware
    Journal of Analytical Chemistry, 2018, 73 : 167 - 175
  • [48] UPLC–MS as a powerful technique for screening the nonvolatile contaminants in recycled PET
    K. Bentayeb
    R. Batlle
    J. Romero
    C. Nerín
    Analytical and Bioanalytical Chemistry, 2007, 388 : 1031 - 1038
  • [49] A novel UPLC-MS-MS method for simultaneous determination of seven uremic retention toxins with cardiovascular relevance in chronic kidney disease patients
    Boelaert, Jente
    Lynen, Frederic
    Glorieux, Griet
    Eloot, Sunny
    Van Landschoot, Maria
    Waterloos, Marie-Anne
    Sandra, Pat
    Vanholder, Raymond
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (06) : 1937 - 1947
  • [50] Metabolite profiling of Panax notoginseng using UPLC-ESI-MS
    Dan, Mo
    Su, Mingming
    Gao, Xianfu
    Zhao, Tie
    Zhao, Aihua
    Xie, Guoxiang
    Qiu, Yunping
    Zhou, Mingmei
    Liu, Zhong
    Jia, Wei
    PHYTOCHEMISTRY, 2008, 69 (11) : 2237 - 2244