Definitive Drug and Metabolite Screening in Urine by UPLC-MS-MS Using a Novel Calibration Technique

被引:9
|
作者
Rosano, Thomas G. [1 ,2 ]
Ohouo, Patrice Y. [2 ]
LeQue, John J. [2 ]
Freeto, Scott M. [3 ]
Wood, Michelle [4 ]
机构
[1] Albany Med Ctr Hosp & Coll, Dept Pathol & Lab Med, Forens Toxicol Lab, 43 New Scotland Ave, Albany, NY 12208 USA
[2] Ctr Med Sci, Natl Toxicol Ctr, Clin & Forens Toxicol Lab, 150 New Scotland Ave, Albany, NY 12208 USA
[3] Waters Corp, Cummings Ctr 100, Suite 407N, Beverly, MA USA
[4] Waters Corp, Hlth Sci Org, Altrincham Rd, Wilmslow, Cheshire, England
关键词
TANDEM MASS-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; TIME-OF-FLIGHT; LABELED INTERNAL STANDARD; LC-MS/MS; WHOLE-BLOOD; ABUSE; VALIDATION; MATRIX; TOXICOLOGY;
D O I
10.1093/jat/bkw050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Drug screening is an essential analytical tool for detection of therapeutic, illicit and emerging drug use. Presumptive immunoassay screening is widely used, while initial definitive testing by chromatography-coupled mass spectrometry is hampered due to complex pre-analysis steps, long chromatography time and matrix effects. The aim of this study is to develop and validate a definitive test for rapid and threshold accurate screening of 33 drugs or metabolites (analytes) in urine. Sample preparation in a 96-well plate format involves rapid glucuronidase hydrolysis followed by dilution, filtration and ultra-performance liquid chromatography-MS-MS analysis. Chromatographic separation, on an ACQUITY UPLCA (R) BEH phenyl column is optimized for a 3-min MS-MS ion acquisition. Matrix effect was normalized by an innovative technique called threshold accurate calibration employing an additional analysis with an analyte spike as an internal standard undergoing the same matrix effect as an analyte in a drug-positive donor specimen. Accuracy and precision, at above and below threshold concentrations, were determined by replicate analysis of control urine pools containing 50, 75, 125 and 150% of threshold concentrations. Accuracy and selectivity were further demonstrated by concordant findings in proficiency and confirmatory testing. The study shows the applicability of definitive testing as an alternative to immunoassay screening and demonstrates a new approach to normalization of matrix effect.
引用
收藏
页码:628 / 638
页数:11
相关论文
共 50 条
  • [1] Screening with Quantification for 64 Drugs and Metabolites in Human Urine using UPLC-MS-MS Analysis and a Threshold Accurate Calibration
    Rosano, Thomas G.
    Ohouo, Patrice Y.
    Wood, Michelle
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2017, 41 (06) : 536 - 546
  • [2] Simple and rapid analysis of amatoxins using UPLC-MS-MS
    Nomura, Mina
    Suzuki, Yudai
    Kaneko, Rina
    Ogawa, Tadashi
    Hattori, Hideki
    Seno, Hiroshi
    Ishii, Akira
    FORENSIC TOXICOLOGY, 2012, 30 (02) : 185 - 192
  • [3] EtG/EtS in Urine from Sexual Assault Victims Determined by UPLC-MS-MS
    Hegstad, Solfrid
    Helland, Arne
    Hagemann, Cecilie
    Michelsen, Lisbeth
    Spigset, Olav
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2013, 37 (04) : 227 - 232
  • [4] Screening of Synthetic Cathinones and Metabolites in Dried Blood Spots by UPLC-MS-MS
    Wang, Yang
    Shi, Yan
    Yu, Yingjia
    Chen, Lizhu
    Jiang, Jiebing
    Long, Jiakun
    Xiang, Ping
    Duan, Gengli
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2021, 45 (07) : 633 - 643
  • [5] Simultaneous determination of 12 sweeteners in foods using UPLC-MS-MS
    Shah, Romina
    Dejager, Lowri S.
    Begley, Timothy
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [6] Simultaneous Determination of Zoalene and Its Metabolite in Chicken Muscle and Liver by SPE and UPLC-MS-MS
    Wu, Yin-Liang
    Xu, Yong
    Yang, Ting
    Huang-Fu, Wei-Guo
    CHROMATOGRAPHIA, 2011, 74 (11-12) : 833 - 838
  • [7] Ultrasensitive UPLC-MS-MS Method for the Quantitation of Etheno-DNA Adducts in Human Urine
    Cui, Shiwei
    Li, Haibin
    Wang, Shaojia
    Jiang, Xiao
    Zhang, Shusheng
    Zhang, Rongjie
    Sun, Xin
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2014, 11 (10) : 10902 - 10914
  • [8] Confirmation of cannabinoids in forensic toxicology casework by isomer-selective UPLC-MS-MS analysis in urine
    Rosano, Thomas G.
    Cooper, Jane A.
    Scholz, Kiley L.
    Wood, Michelle
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2023, 47 (08) : 709 - 718
  • [9] Simultaneous Analysis of Cannabinoid and Synthetic Cannabinoids in Dietary Supplements Using UPLC with UV and UPLC-MS-MS
    Heo, Seok
    Yoo, Geum Joo
    Choi, Ji Yeon
    Park, Hyoung Joon
    Do, Jung-Ah
    Cho, Sooyeul
    Baek, Sun Young
    Park, Sung-Kwan
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2016, 40 (05) : 350 - 359
  • [10] High-throughput Quantification of Cotinine in Urine, Serum and Meconium by UPLC-MS-MS With Automated SPE
    Langlois, Eric
    Bisson, David
    Lefebvre, Michel
    Simard, Yves