Matrix effects of concomitant species on the determination of nickel by inductively coupled plasma atomic emission spectrometry

被引:0
|
作者
Akba, O [1 ]
Baysal, A [1 ]
Merdivan, M [1 ]
Hamamci, C [1 ]
Gumgum, B [1 ]
机构
[1] Dicle Univ, Fac Sci & Arts, Dept Chem, TR-21280 Diyarbakir, Turkey
关键词
matrix effect; concomitant species; nickel; ICP-AES;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The interference on the determination of nickel by the salts LiCl, NaCl, KCl, CsCl, NH4Cl, Na2SO4, NaNO3, NaC2H3O2 in an inductively coupled plasma-atomic emission spectrometry has been carried out. The salt concentration was in the 100-10000 mg L-1 range. Nickel emission was enhanced at lower matrix concentrations (100 mg L-1) and was depressed at higher matrix concentrations (10000 mg L-1). Except cesium, above 100 mg L-1, all studied ions caused a decrease in the signal intensity in the range of 0-15%. The sequence order of the investigated ions for the enhancement and depression was unstable. The sequence order in enhancement was found as Li+ < Na+ < K+ < Cs+ < NH4+ for cation; NO3- < SO42- < Cl- < OAc- for anions and Cs+ < NH4+ < K+ < Li+ < Na+ for cat-ions and OAc- < SO42- Cl- < NO3- for anions in depression at the studied lines.
引用
收藏
页码:1518 / 1526
页数:9
相关论文
共 50 条
  • [31] Determination of impurities in aluminum isopropoxide by inductively coupled plasma atomic emission spectrometry
    Evdokimov, I. I.
    Pimenov, V. G.
    INORGANIC MATERIALS, 2010, 46 (03) : 318 - 322
  • [32] Determination of arsenic, mercury, and selenium by inductively coupled plasma atomic emission spectrometry
    Lakota, VN
    Makarevich, VI
    Arkhutik, SS
    Kolomiets, ND
    Murokh, VI
    JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 54 (03) : 251 - 253
  • [33] Comparison of pneumatic and ultrasonic nebulizations in inductively coupled plasma atomic emission spectrometry - matrix effects and plasma parameters
    Borkowska-Burnecka, Jolanta
    Lesniewicz, Anna
    Zymicki, Wieslaw
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (05) : 579 - 587
  • [34] Determination of total sulfur in coal by inductively coupled plasma atomic emission spectrometry
    Liu, DY
    Zhang, YL
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2002, 22 (01) : 89 - 91
  • [35] DETERMINATION OF PLATINUM IN URINE BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY
    LO, FB
    ARAI, DK
    NAZAR, MA
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1987, 11 (06) : 242 - 246
  • [37] Determination of impurities in aluminum isopropoxide by inductively coupled plasma atomic emission spectrometry
    I. I. Evdokimov
    V. G. Pimenov
    Inorganic Materials, 2010, 46 : 318 - 322
  • [38] Determination of Arsenic and Antimony in Ferrotungsten by Inductively Coupled Plasma Atomic Emission Spectrometry
    Maiorova, A. V.
    Belozerova, A. A.
    Mel'chakov, S. Yu.
    Mashkovtsev, M. A.
    Suvorkina, A. S.
    Shunyaev, K. Yu.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 74 (Suppl 1) : S18 - S26
  • [39] Determination of Total Sulfur in Coal by Inductively Coupled Plasma Atomic Emission Spectrometry
    Liu, Dong-Yan
    Zhang, Yuan-Li
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2002, 22 (01): : 90 - 91
  • [40] GENERATION OF STIBINE AND DETERMINATION OF ANTIMONY BY EMISSION ATOMIC SPECTROMETRY WITH INDUCTIVELY COUPLED PLASMA
    JARON, I
    FIJALKOWSKI, J
    CHEMIA ANALITYCZNA, 1987, 32 (04): : 519 - 530