Ultrasound speed in articular cartilage under mechanical compression

被引:28
|
作者
Nieminen, Heikki J.
Julkunen, Petro
Toeyraes, Juha
Jurvelin, Jukka S.
机构
[1] Kuopio Univ Hosp, Dept Clin Neurophysiol, SF-70210 Kuopio, Finland
[2] Univ Kuopio, FIN-70211 Kuopio, Finland
[3] Kuopio Univ Hosp, Dept Clin Physiol & Nucl Med, Kuopio, Finland
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2007年 / 33卷 / 11期
基金
芬兰科学院;
关键词
articular cartilage; osteoarthrosis; mechanical indentation; ultrasound speed; finite element modeling;
D O I
10.1016/j.ultrasmedbio.2007.06.001
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound elastography is a method that can be used to determine the elastic properties of soft tissues and it has been recently applied to study of articular cartilage. While ultrasound elastography techniques assume a constant ultrasound speed in tissue under mechanical compression, ultrasound speed in articular cartilage has been found to vary depending on the loading conditions. This may limit the quantitative use of the technique for determination of the elastic properties of articular cartilage along the axis of ultrasound propagation. The aim of the present study was to investigate the origin of the load-related variation in ultrasound speed. Samples of human and bovine articular cartilage (n = 82) were mechanically and acoustically tested during unconfined compression. A statistically significant (p < 0.05) variation of ultrasound speed was found in cartilage during a stress-relaxation test. A finite element model was constructed by exploiting microscopically determined collagen and proteoglycan contents, collagen orientation and biochemical analyses of water content. From the finite element simulations, collagen orientation and the void ratio (fluid-to-solid ratio) as a function of time were assessed and, together with the experimentally determined ultrasound speed, a linear model predicting variation of the ultrasound speed in human articular cartilage under mechanical compression was established. The model predicted compression-related ultrasound speed with an error of < 0.3% at each time point. The effect of strain rate on variation of ultrasound speed was tested in bovine cartilage samples. The decrease in ultrasound speed was found to be proportional to the strain rate. The results suggest that ultrasound speed in articular cartilage is controlled mainly by collagen orientation and the void ratio and depends on the imposed strain rate. A numerical simulation revealed that the compression-related decrease in ultrasound speed induces notable errors in mechano-acoustically determined strain. A method to eliminate the compression-related errors in measured strain and elastic properties may be needed in mechano-acoustic measurements of articular cartilage. (E-mail: heikki.nieminen@uku.fi) (c) 2007 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1755 / 1766
页数:12
相关论文
共 50 条
  • [21] Ratcheting behavior of articular cartilage under cyclic unconfined compression
    Gao, Li-Lan
    Qin, Xiao-Yi
    Zhang, Chun-Qiu
    Gao, Hong
    Ge, Hong-Yu
    Zhang, Xi-Zheng
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 57 : 371 - 377
  • [22] The characteristics of ultrasound speed and attenuation in progressive trypsin digested articular cartilage
    Sun Feng
    Wu Zhiyong
    Shao Xiaoning
    Wang Yuexiang
    Zhang Lihai
    Niu Haijun
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 1184 - +
  • [23] THE MECHANICAL BEHAVIOR OF ARTICULAR CARTILAGE UNDER COMPRESSIVE STRESS
    CAMOSSO, ME
    MAROTTI, G
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1962, 44 (04): : 699 - 709
  • [24] Acoustic properties of articular cartilage under mechanical stress
    Nieminen, Heikki J.
    Toyras, Juha
    Laasanen, Mikko S.
    Jurvelin, Jukka S.
    BIORHEOLOGY, 2006, 43 (3-4) : 523 - 535
  • [25] Mechanical response of bovine articular cartilage under dynamic unconfined compression loading at physiological stress levels
    Park, S
    Hung, CT
    Ateshian, GA
    OSTEOARTHRITIS AND CARTILAGE, 2004, 12 (01) : 65 - 73
  • [26] Mechanical states of repaired full-thickness defects of articular cartilage by tissue engineering under compression
    Bao, Yan
    Liu, Haiying
    Liu, Qing
    Gao, Lilan
    Zhang, Chunqiu
    ADVANCED MATERIALS AND PROCESSES III, PTS 1 AND 2, 2013, 395-396 : 658 - 661
  • [27] Injurious mechanical compression of bovine articular cartilage induces chondrocyte apoptosis
    Loening, AM
    James, IE
    Levenston, ME
    Badger, AM
    Frank, EH
    Kurz, B
    Nuttall, ME
    Hung, HH
    Blake, SM
    Grodzinsky, AJ
    Lark, MW
    ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 2000, 381 (02) : 205 - 212
  • [28] Sodium multiple quantum spectroscopy of articular cartilage: Effects of mechanical compression
    Duvvuri, U
    Kaufman, JH
    Patel, SD
    Bolinger, L
    Kneeland, JB
    Leigh, JS
    Reddy, R
    MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) : 370 - 375
  • [29] Biosynthetic response and mechanical properties of articular cartilage after injurious compression
    Kurz, B
    Jin, M
    Patwari, P
    Cheng, DM
    Lark, MW
    Grodzinsky, AJ
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2001, 19 (06) : 1140 - 1146
  • [30] Ultrasound Elastography to Determine the Layered Mechanical Properties of Articular Cartilage and the Importance of Such Structural Characteristics under Load
    McCredie, Alexandra J.
    Stride, Eleanor
    Saffari, Nader
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 4262 - 4265