2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series

被引:97
|
作者
Gras, Florian [1 ]
Marintschev, Ivan [1 ]
Wilharm, Arne [1 ]
Klos, Kajetan [1 ]
Mueckley, Thomas [1 ]
Hofmann, Gunther O. [1 ,2 ]
机构
[1] Univ Jena, Dept Trauma Hand & Reconstruct Surg, D-6900 Jena, Germany
[2] Berufsgenossenschaftl Kliniken Halle, Halle, Germany
来源
关键词
ILIOSACRAL SCREWS; INTERNAL-FIXATION; FRACTURE-DISLOCATIONS; SACROILIAC SCREWS; SUPINE POSITION; PLACEMENT; STABILIZATION; DISRUPTIONS; FLUOROSCOPY; INSERTION;
D O I
10.1186/1471-2474-11-153
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Screw fixation of pelvic ring fractures is a common, but demanding procedure and navigation techniques were introduced to increase the precision of screw placement. The purpose of this case series was the evaluation of screw misplacement rate and functional outcome of percutaneous screw fixation of pelvic ring disruptions using a 2D navigation system. Methods: Between August 2004 and December 2007, 44 of 442 patients with pelvic injuries were included for closed reduction and percutaneous screw fixation of disrupted pelvic ring lesions using an optoelectronic 2D-fluoroscopic based navigation system. Operating and fluoroscopy time were measured, as well as peri- and postoperative complications documented. Screw position was assessed by postoperative CT scans. Quality of live was evaluated by SF 36-questionnaire in 40 of 44 patients at mean follow up 15.5 +/- 1.2 month. Results: 56 iliosacral- and 29 ramus pubic-screws were inserted ( mean operation time per screw 62 +/- 4 minutes, mean fluoroscopy time per screw 123 +/- 12 seconds). In post-operative CT-scans the screw position was assessed and graded as follows: I. secure positioning, completely in the cancellous bone (80%); II. secure positioning, but contacting cortical bone structures (14%); III. malplaced positioning, penetrating the cortical bone (6%). The malplacements predominantly occurred in bilateral overlapping screw fixation. No wound infection or iatrogenic neurovascular damage were observed. Four re-operations were performed, two of them due to implant-misplacement and two of them due to implant-failure. Conclusion: 2D-fluoroscopic navigation is a safe tool providing high accuracy of percutaneous screw placement for pelvic ring fractures, but in cases of a bilateral iliosacral screw fixation an increased risk for screw misplacement was observed. If additional ramus pubic screw fixations are performed, the retrograde inserted screws have to pass the iliopubic eminence to prevent an axial screw loosening.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Isolated pelvic ring injuries: functional outcomes following percutaneous, posterior fixation
    Sullivan M.P.
    Scolaro J.A.
    Milby A.H.
    Mehta S.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (6) : 1025 - 1030
  • [32] TiRobot‑assisted versus conventional fluoroscopy-assisted percutaneous sacroiliac screw fixation for pelvic ring injuries: a meta‑analysis
    Chunpeng Zhao
    Gang Zhu
    Yu Wang
    Xinbao Wu
    Journal of Orthopaedic Surgery and Research, 17
  • [33] Freehand Placement of a Transiliac-Transsacral Screw for Fixation of Posterior Pelvic Ring Injuries
    Liu, Guangping
    Chen, Zhiguang
    Cao, Wenhao
    Zheng, Yubo
    Li, Jiaqi
    He, Jie
    Li, Changda
    Chen, Hua
    Tang, Peifu
    ORTHOPAEDIC SURGERY, 2025, 17 (03) : 781 - 789
  • [34] Minimally Invasive Fluoro-Navigation Screw Fixation for the Treatment of Pelvic Ring Injuries
    Gao, Hong
    Luo, Cong-Feng
    Hu, Cheng-Fang
    Zhang, Chang-Qing
    Zeng, Bing-Fang
    SURGICAL INNOVATION, 2011, 18 (03) : 279 - 284
  • [35] PERCUTANEOUS ILIOSACRAL SCREW FIXATION - EARLY TREATMENT FOR UNSTABLE POSTERIOR PELVIC RING DISRUPTIONS
    SHULER, TE
    BOONE, DC
    GRUEN, GS
    PEITZMAN, AB
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1995, 38 (03): : 453 - 458
  • [36] CT-guided percutaneous screw fixation of pelvic traumatic injuries: About 55 cases
    Eude, PD
    Trojani, C
    Eude, G
    Piche, S
    Aboulker, C
    De Peretti, F
    RADIOLOGY, 2001, 221 : 560 - 560
  • [37] Functional Outcome With Percutaneous Ilio-sacral Screw Fixation For Posterior Pelvic Ring Injuries In Patients Involved In Heavy Manual Laboring
    Abhishek, S. M.
    Prashanth
    Azhar, A. L.
    Vijay, G. B.
    Harshal, K.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2015, 9 (03) : 23 - 27
  • [38] Open reduction internal fixation versus percutaneous iliosacral screw fixation for unstable posterior pelvic ring disruptions
    Elzohairy, M. M.
    Salama, A. M.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (02) : 223 - 227
  • [39] Percutaneous anterior transarticular screw fixation for atlantoaxial instability A CASE SERIES
    Li, W. -L.
    Chi, Y. -L.
    Xu, H. -Z.
    Wang, X. -Y.
    Lin, Y.
    Huang, Q. -S.
    Mao, F. -M.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (04): : 545 - 549
  • [40] Trans-sacral screw fixation of posterior pelvic ring injuries: review and expert opinion
    Ziran, Navid
    Collinge, Cory A.
    Smith, Wade
    Matta, Joel M.
    PATIENT SAFETY IN SURGERY, 2022, 16 (01)