Percutaneous pins versus volar plates for unstable distal radius fractures: A biomechanical study using a cadaver model.

被引:0
|
作者
Knox, I
Trumble, TE
Ambrose, H
McCallister, W
机构
[1] Univ Washington, Sch Med, Harborview Biomech Lab, Seattle, WA USA
[2] Univ Washington, Sch Med, Dept Orthopaed & Sports Med, Seattle, WA USA
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
489
引用
收藏
页码:S163 / S163
页数:1
相关论文
共 50 条
  • [41] Volar versus dorsal fixed-angle fixation of dorsally unstable extra-articular distal radius fractures: A biomechanic study
    McCall, Todd A.
    Conrad, Bryan
    Badman, Brian
    Wright, Thomas
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (06): : 806 - 812
  • [42] 145 Outcomes of Unstable Distal Radius Fractures - A Meta-Analysis of Bridging External Fixation Versus Volar Plating
    Mulrain, J.
    Joshi, K.
    Doyle, F.
    Abdulkarim, A.
    BRITISH JOURNAL OF SURGERY, 2021, 108 (SUPPL 2)
  • [43] A Comparative Study of Fragment-Specific versus Volar Plate Fixation of Distal Radius Fractures
    Sammer, Douglas M.
    Fuller, Douglas S.
    Kim, Hyungjin Myra
    Chung, Kevin C.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2008, 122 (05) : 1441 - 1450
  • [44] Volar Locking Plates Versus K-Wire Fixation of Dorsally Displaced Distal Radius Fractures-A Functional Outcome Study
    Hull, Peter
    Baraza, Njalalle
    Gohil, Milesh
    Whalley, Helen
    Mauffrey, Cyril
    Brewster, Mark
    Costa, Matthew L.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 70 (06): : E125 - E128
  • [45] Biomechanical Comparison of Volar Fixed-Angle Locking Plates for AO C3 Distal Radius Fractures: Titanium Versus Stainless Steel With Compression
    Marshall, Tyler
    Momaya, Amit
    Eberhardt, Alan
    Chaudhari, Nilesh
    Hunt, Thomas R., III
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (10): : 2032 - 2038
  • [46] Number and Locations of Screw Fixation for Volar Fixed-Angle Plating of Distal Radius Fractures: Biomechanical Study
    Mehling, Isabella
    Mueller, Lars P.
    Delinsky, Katharina
    Mehler, Dorothea
    Burkhart, Klaus J.
    Rommens, Pol M.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (06): : 885 - 891
  • [47] Biomechanical study of four palmar locking plates and one non-locking palmar plate for distal radius fractures: stiffness and load to failure tests in a cadaver model
    Rudig, Lothar
    Mehling, Isabella
    Klitscher, Daniela
    Mehler, Dorothea
    Prommersberger, Karl-Josef
    Rommens, Pol M.
    Mueller, Lars Peter
    BIOMEDIZINISCHE TECHNIK, 2009, 54 (03): : 150 - 158
  • [48] A biomechanical comparison of a dorsal 3.5-mm T-plate and a volar fixed-angle plate in a model of dorsally unstable distal radius fractures
    Liporace, FA
    Gupta, S
    Jeong, GK
    Stracher, M
    Kummer, F
    Egol, KA
    Koval, KJ
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (03) : 187 - 191
  • [49] A Biomechanical Comparison of Volar Locked Plating of Intra-Articular Distal Radius Fractures: Use of 4 Versus 7 Screws for Distal Fixation
    Moss, David P.
    Means, Kenneth R., Jr.
    Parks, Brent G.
    Forthman, Christopher L.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (12): : 1907 - 1911
  • [50] Stability of volar locking plate systems for AO type C3 fractures of the distal radius: biomechanical study in a cadaveric model
    Kamei, Shuzo
    Osada, Denju
    Tamai, Kazuya
    Kato, Nakayuki
    Takai, Morimitsu
    Kameda, Masahiro
    Nohara, Yutaka
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2010, 15 (03) : 357 - 364