Characterisation of a micro-total analytical system for the determination of nitrite with spectrophotometric detection

被引:126
|
作者
Greenway, GM [1 ]
Haswell, SJ [1 ]
Petsul, PH [1 ]
机构
[1] Univ Hull, Dept Chem, Kingston Upon Hull HU6 7RX, N Humberside, England
关键词
micro flow injection analysis; nitrite; miniaturisation; mu TAS;
D O I
10.1016/S0003-2670(99)00047-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A micro-total analytical system (mu TAS) is described for the determination of nitrite based on its reaction with sulphanilamide to form the diazonium salt which when coupled with N-(1-naphthyl) ethylene diamine yields an azo dye whose absorbance was measured at 526 nm. The reaction took place in an etched glass manifold containing channels 302 mu m wide and 115 mu m deep in which electro-osmotic how was used to move the reagents. The absorbance of the product was measured in situ using a micro-spectrophotometric-fibre optic detection system. The electro-osmotic flow mixing characteristics of the reagents together with the production of the colorimetric complex have been investigated. in addition methods for obtaining sensitive detection in the micro-reactor are reported. Using the conditions established a linear calibration was obtained between 0 and 100 mu M with a correlation coefficient of 0.999. The RSD at 50 mu M NO2- was 2.6% (n=6) and the limit of detection obtained (3 sigma) was 0.20 mu M NO2-. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [21] Developments toward a complete micro-total analysis system for Duchenne muscular dystrophy diagnosis
    Ferrance, JP
    Wu, QR
    Giordano, B
    Hernandez, C
    Kwok, Y
    Snow, K
    Thibodeau, S
    Landers, JP
    ANALYTICA CHIMICA ACTA, 2003, 500 (1-2) : 223 - 236
  • [22] A paper origami-based micro-total electrochemical immunoassay (μTEI) for the detection of total malachite green in aquatic products
    Wu, Jing
    Jing, Xu
    Liu, Yong
    Zhao, Luyao
    Ji, Xuemeng
    Fu, Hanyue
    Zhang, Bowei
    Zhang, Yan
    Wang, Shuo
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 361
  • [23] SPOT TEST DETECTION AND SPECTROPHOTOMETRIC DETERMINATION OF NITRITE WITH P-PHENYLAZOANILINE
    SAWICKI, E
    STANLEY, TW
    ELBERT, WC
    ANALYTICAL CHEMISTRY, 1962, 34 (02) : 297 - &
  • [24] SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF NITRITE AND NITRATE IN A FLOW-INJECTION SYSTEM
    KOJLO, A
    GORODKIEWICZ, E
    ANALYTICA CHIMICA ACTA, 1995, 302 (2-3) : 283 - 287
  • [25] Kinetic spectrophotometric determination of hydrazine with neutral red-nitrite system
    Wang S.
    Du L.
    Zhang A.
    Liu D.
    Mikrochimica Acta, 2000, 134 (3-4) : 167 - 170
  • [26] Catalytic simultaneous spectrophotometric determination of nitrite and nitrate with a flow injection system
    Zhi-Qi, Z
    Lou-Jun, G
    Han-Ying, Z
    Qian-Guang, L
    ANALYTICA CHIMICA ACTA, 1998, 370 (01) : 59 - 63
  • [27] A new system for the spectrophotometric determination of trace amounts of nitrite in environmental samples
    Cherian, Tom
    Narayana, Badiadka
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2006, 17 (03) : 577 - 581
  • [28] KINETIC SPECTROPHOTOMETRIC DETERMINATION OF NITRITE WITH TROPAEOLIN 00-BROMATE SYSTEM
    Moldovan, Z.
    ANALYTICAL LETTERS, 2010, 43 (7-8) : 1344 - 1354
  • [29] Determination of Nitrite and Nitrate in Natural Waters Using Flow Injection with Spectrophotometric Detection
    Yaqoob, Mohammad
    Nabi, Abdul
    Worsfold, Paul John
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2013, 35 (02): : 533 - 539
  • [30] Determination of nitrite and nitrate in dairy products by ion exchange LC with spectrophotometric detection
    Gapper, LW
    Fong, BY
    Otter, DE
    Indyk, HE
    Woollard, DC
    INTERNATIONAL DAIRY JOURNAL, 2004, 14 (10) : 881 - 887