Automatic Arrhythmia Detection Based on Heart Beat Interval Series Recorded Through Bed Sensors During Sleep

被引:0
|
作者
Migliorini, Matteo [1 ]
Cabiddu, Ramona [1 ]
Cerutti, Sergio [1 ]
Mainardi, Luca T. [1 ]
Kortelainen, Juha M. [2 ]
Bianchi, Anna M. [1 ]
机构
[1] Politecn Milan, Dept Bioengn, Via Golgi 39, I-20133 Milan, Italy
[2] VTT Tech Res Ctr Finland, Tampere, Finland
来源
关键词
CARDIAC-ARRHYTHMIAS; APNEA;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A high frequency of cardiac arrhythmias has been reported in sleep disordered patients. In order to detect the presence of arrhythmia during sleep, cardiac activity needs to be monitored. Several devices exist able to provide reliable Heart Rate Variability (HRV) measures in a minimally-intrusive way. Hence, there is the need for the development of robust methods for arrhythmia detection based on HRV measures. In the present study a method for automatic arrhythmia detection based on the analysis of an inter-beat series was developed and validated on recordings coming from the MIT-BIH Arrhythmia Database. The method was also applied on a beat to beat interval series obtained from the ballistocardiographic (BCG) signal of one subject, which was recorded during sleep using an innovative bed sensor which allowed for a noncontact and unobtrusive recording. When compared to the results of arrhythmia detection performed on the electrocardiographic (ECG) signal (concurrently acquired using polysomnography) using Cardioline Cube HOLTER analysis software, our method achieved a sensitivity of 55.6%, a specificity of 94.7% and an accuracy of 91.8%. Our results suggest that the bed sensor could represent a reliable tool to assist the clinician in arrhythmia detection.
引用
收藏
页码:337 / 340
页数:4
相关论文
共 25 条
  • [21] Automatic video detection of body movement during sleep based on optical flow in pediatric patients with epilepsy
    Cuppens, Kris
    Lagae, Lieven
    Ceulemans, Berten
    Van Huffel, Sabine
    Vanrumste, Bart
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2010, 48 (09) : 923 - 931
  • [22] Automatic video detection of body movement during sleep based on optical flow in pediatric patients with epilepsy
    Kris Cuppens
    Lieven Lagae
    Berten Ceulemans
    Sabine Van Huffel
    Bart Vanrumste
    Medical & Biological Engineering & Computing, 2010, 48 : 923 - 931
  • [23] Quantitative evaluation of heart beat interval time series via Poincare analysis reveals distinct patterns of cardiac rate dynamics during cycles of vagus nerve stimulation heart failure patients
    Libbus, I.
    Nearing, B. D.
    Amurthur, B.
    Kenknight, B. H.
    Verrier, R. L.
    EUROPEAN HEART JOURNAL, 2017, 38 : 905 - 905
  • [24] Real-time continuous estimation of respiratory frequency during sleep based on heart rate time series
    Yoshida, Yutaka
    Yokoyama, Kiyoko
    Ishii, Naohiro
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 648 - +
  • [25] Identifying the undiagnosed AF patient through "Know Your Pulse" community pharmacy based events held in ten countries during Arrhythmia Alliance World Heart Rhythm Week 2017
    Lobban, T.
    Breakwell, N.
    Hamedi, N.
    Antoniou, S.
    Alves De Costa, F.
    Tous, S.
    Papastergiou, J.
    Derango, F.
    Griffiths, D.
    Chaumais, M. -C.
    Viola, R.
    Ladova, K.
    Paulino, E.
    Hersberger, K.
    Freedman, B.
    EUROPEAN HEART JOURNAL, 2018, 39 : 263 - 264