Point Target Correction Coefficients For Absolute SAR Calibration

被引:0
|
作者
Doering, Bjoern J. [1 ]
Looser, Philipp [1 ]
Jirousek, Matthias [1 ]
Schwerdt, Marco [1 ]
机构
[1] German Aerosp Ctr DLR, Microwaves & Radar Inst, Oberpfaffenhofen, Germany
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A synthetic aperture radar (SAR) system measures the radar reflectivity of the earth's surface for a multitude of scientific and commercial applications. In many cases, accurate absolutely calibrated images are required by end-users. The backscattering from man-made point targets like passive corner reflectors and active transponders is often used as a radiometric calibration standard for synthetic aperture radar (SAR) calibration. As new systems emerge and the demand for more accurate systems increases, it becomes necessary to better understand the effects of real or imperfect targets on the calibration results. Therefore, a point target SAR simulator is presented which models the complete external radiometric calibration process. It incorporates a number of target properties like frequency response, transponder internal calibration strategies, noise, and interference signals, and it takes the SAR mode settings into consideration. Thereby, the relevant target backscatter variation as observed in the processed SAR image with respect to an ideal or any other target can be determined. The simulation results are relevant both during the design process of a new target as well as during the actual calibration. Based on these point target simulations, correction coefficients can be stated for each target and SAR mode, therefore decreasing the remaining radiometric point target uncertainties. Also, the cross-calibration between two different SAR systems becomes more accurate.
引用
收藏
页码:1087 / 1092
页数:6
相关论文
共 50 条
  • [21] Potential for Absolute Ionosphere and Clock Correction in Noncooperative Bistatic SAR
    Azcueta, Mario
    Tebaldini, Stefano
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2020, 58 (01): : 363 - 377
  • [22] Software for the absolute correction color values and calibration of spectrometers, an instrument correction program
    Ladson, JA
    Fairman, H
    IS&T'S NIP21: INTERNATIONAL CONFERENCE ON DIGITAL PRINTING TECHNOLOGIES, FINAL PROGRAM AND PROCEEDINGS, 2005, : 476 - 479
  • [23] COMPACT POLARIMETRIC SAR PRODUCT AND CALIBRATION CONSIDERATIONS FOR TARGET ANALYSIS
    Sabry, Ramin
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XX, 2016, 10000
  • [24] A NEW DISTRIBUTED TARGET EXTRACTION METHOD FOR POLARIMETRIC SAR CALIBRATION
    Chi, Bowen
    Zhang, Jixian
    Lu, Lijun
    Yang, Shucheng
    Huang, Guoman
    14TH GEOINFORMATION FOR DISASTER MANAGEMENT, GI4DM 2022, VOL. 10-3, 2022, : 31 - 36
  • [25] ABSOLUTE CALIBRATION OF LOW-ENERGY, THICK TARGET BREMSSTRAHLUNG
    VONNEUMANNCOSEL, P
    HUXEL, N
    RICHTER, A
    SPIELER, C
    CARROLL, JJ
    COLLINS, CB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 338 (2-3): : 425 - 431
  • [26] Ionosphere Estimation and Correction for Geosynchronous SAR based on point target deviation between Range Sub-images
    Huang Lijia
    Ding Chibiao
    Qiu Xiaolan
    Zhang Hongyi
    Li Liang
    PROCEEDINGS OF 2016 IEEE 13TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING (ICSP 2016), 2016, : 1886 - 1889
  • [27] New method of point target detection for SAR image
    Wan, P
    Wang, JG
    Zhao, ZQ
    Huang, SJ
    TARGETS AND BACKGROUNDS VI: CHARACTERIZATION, VISUALIZATION, AND THE DETECTION PROCESS, 2000, 4029 : 136 - 140
  • [28] Study of point target spectrum for bistatic SAR imaging
    Ding, Jin-Shan
    Loffeld, Otmar
    Nies, Holger
    Xing, Meng-Dao
    Bao, Zheng
    Dianzi Yu Xinxi Xuebao/Journal of Electronics and Information Technology, 2009, 31 (04): : 763 - 767
  • [29] Absolute SPECT quantitation using a point source calibration.
    Tang, HR
    Da Silva, AJ
    Hasegawa, BH
    Hawkins, RA
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 101P - 101P
  • [30] SAR Image Absolute Radiometric Calibration Based on RCS Modeling of Communication Tower
    Li J.
    Li Y.
    Zhao Q.
    Jiang H.
    Hong Y.
    Wuhan Daxue Xuebao (Xinxi Kexue Ban)/Geomatics and Information Science of Wuhan University, 2021, 46 (11): : 1746 - 1755