Comparative Analysis of Optical Surface Measuring Systems with a Chirp Calibration Standard

被引:8
|
作者
Pehnelt, Sebastian [1 ]
Osten, Wolfgang [2 ]
Seewig, Joerg [3 ]
机构
[1] AUDI AG, D-85045 Ingolstadt, Germany
[2] Univ Stuttgart, Inst Tech Opt, D-70569 Stuttgart, Germany
[3] Tech Univ Kaiserslautern, Lehstuhl Messtech & Sensor, D-67663 Kaiserslautern, Germany
关键词
Chirp calibration standard; interference microscope; confocal microscope; microtopography; WHITE-LIGHT INTERFEROMETRY;
D O I
10.1524/teme.2011.0146
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this article the characteristics of optical topography measuring systems are analyzed by a chirp calibration standard. With the aid of this standard it should be possible to characterize the instrument transfer behaviour of surface measuring devices. In this special case a white light interference microscope and a confocal microscope are compared. The measurement results show differences which can be used for the characterization of optical surface measuring devices with respect to their applicability for technical surfaces.
引用
收藏
页码:457 / 462
页数:6
相关论文
共 50 条
  • [31] The Si surface yield as a calibration standard for RBS
    Bianconi, M
    Abel, F
    Banks, JC
    Font, AC
    Cohen, C
    Doyle, BL
    Lotti, R
    Lulli, G
    Nipoti, R
    Vickridge, I
    Walsh, D
    Wendler, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 161 : 293 - 296
  • [32] CHIRP-INDUCED PENALTY IN OPTICAL FIBER SYSTEMS
    OREILLY, JJ
    SILVA, HJA
    ELECTRONICS LETTERS, 1987, 23 (19) : 992 - 993
  • [33] STANDARD MEASURING SYSTEM FOR CALIBRATION OF MAGNETIC FLUX DENSITY GRADIOMETERS
    Khorev, V. N.
    Shifrin, V. Ya
    Shubin, S. A.
    Park, P. G.
    2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 314 - +
  • [34] A NEW STANDARD PARTIAL DISCHARGE GAUGE FOR CALIBRATION OF MEASURING CIRCUITS
    TANASESCU, F
    ARCHIV FUR TECHNISCHES MESSEN UND MESSTECHNISCHE PRAXIS, 1969, (405): : 221 - +
  • [35] Comparative analysis of summary scoring systems in measuring fecal incontinence
    Seong, Moo-Kyung
    Jung, Sung-Il
    Kim, Tae-won
    Joh, Hee-Kyung
    JOURNAL OF THE KOREAN SURGICAL SOCIETY, 2011, 81 (05): : 326 - 331
  • [36] Calibration of areal surface topography measuring instruments
    Seewig, J.
    Eifler, M.
    FIFTH INTERNATIONAL CONFERENCE ON OPTICAL AND PHOTONICS ENGINEERING, 2017, 10449
  • [37] A single standard calibration module for flow analysis systems based on solenoid microdevices
    Tymecki, Lukasz
    Strzelak, Kamil
    Koncki, Robert
    TALANTA, 2009, 79 (02) : 205 - 210
  • [38] An inter-laboratory study of the calibration of optical full-field systems for measuring deformation
    Hack, Erwin
    JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 2016, 51 (01): : 90 - 98
  • [39] STANDARD SAMPLES AND CALIBRATION OF PIXE ANALYSIS
    KASAHARA, M
    TAKAHASHI, K
    SAKISAKA, M
    TOMITA, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 75 (1-4): : 136 - 139
  • [40] ABSOLUTE FLUX CALIBRATION OF OPTICAL SPECTROPHOTOMETRIC STANDARD STARS
    COLINA, L
    BOHLIN, RC