Automatic alignment and reconstruction of images for soft X-ray tomography

被引:68
|
作者
Parkinson, Dilworth Y. [2 ]
Knoechel, Christian [1 ]
Yang, Chao [3 ]
Larabell, Carolyn A. [1 ,4 ]
Le Gros, Mark A. [4 ]
机构
[1] Univ Calif San Francisco, Dept Anat, San Francisco, CA 94143 USA
[2] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Adv Light Source, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Computat Res Div, Berkeley, CA 94720 USA
[4] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Phys Biosci Div, Berkeley, CA 94720 USA
关键词
3D imaging; Image processing; FIDUCIAL-LESS ALIGNMENT; MARKER-FREE ALIGNMENT; ORIENTATION REFINEMENT; ELECTRON; RESOLUTION; MICROSCOPY; VISUALIZATION; PACKAGE;
D O I
10.1016/j.jsb.2011.11.027
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Soft X-ray tomography (SXT) is a powerful imaging technique that generates quantitative, 3D images of the structural organization of whole cells in a near-native state. SXT is also a high-throughput imaging technique. At the National Center for X-ray Tomography (NCXT), specimen preparation and image collection for tomographic reconstruction of a whole cell require only minutes. Aligning and reconstructing the data, however, take significantly longer. Here we describe a new component of the high throughput computational pipeline used for processing data at the NCXT. We have developed a new method for automatic alignment of projection images that does not require fiducial markers or manual interaction with the software. This method has been optimized for SXT data sets, which routinely involve full rotation of the specimen. This software gives users of the NCXT SXT instrument a new capability - virtually real-time initial 3D results during an imaging experiment, which can later be further refined. The new code, Automatic Reconstruction 3D (AREC3D), is also fast, reliable, and robust. The fundamental architecture of the code is also adaptable to high performance GPU processing, which enables significant improvements in speed and fidelity. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:259 / 266
页数:8
相关论文
共 50 条
  • [21] Constrained X-ray tensor tomography reconstruction
    Vogel, Jakob
    Schaff, Florian
    Fehringer, Andreas
    Jud, Christoph
    Wieczorek, Matthias
    Pfeiffer, Franz
    Lasser, Tobias
    OPTICS EXPRESS, 2015, 23 (12): : 15134 - 15151
  • [22] Closed surface reconstruction in X-ray tomography
    Soussen, C
    Mohammad-Djafari, A
    2001 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL I, PROCEEDINGS, 2001, : 718 - 721
  • [23] Blind reconstruction of x-ray penumbral images
    Chen, YW
    Otsuki, K
    Nakao, Z
    Kodama, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (05): : 1966 - 1969
  • [24] Reconstruction of multi-energy x-ray computed tomography images of laboratory mice
    Gleason, SS
    Sari-Sarraf, H
    Paulus, MJ
    Johnson, DK
    Norton, SJ
    Abidi, MA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) : 1081 - 1086
  • [25] Soft X-ray holographic tomography for biological specimens
    Gao, HY
    Chen, JW
    Xie, HL
    Li, RX
    Xu, ZZ
    Jiang, SP
    Zhang, YX
    NOVEL OPTICAL INSTRUMENTATION FOR BIOMEDICAL APPLICATIONS, 2003, 5143 : 215 - 223
  • [26] Automatic Marker Detection from X-Ray Images
    Fang, Fei
    Liu, Yaping
    Yao, Jian
    Li, Yinxuan
    Xie, Renping
    2013 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2013, : 1689 - 1694
  • [27] Automatic detection of blasting caps in X-ray images
    Slamani, MA
    Slamani, AA
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XXVI, 2003, 5203 : 53 - 62
  • [28] Soft X-ray Tomography on HT-7
    陈开云
    胡立群
    丁玥
    马天鹏
    段艳敏
    Plasma Science and Technology, 2009, 11 (04) : 472 - 476
  • [29] Automatic inspection of weld defects in X-ray images
    Sun, Yi
    Zhou, Ping
    Wang, En-Liang
    Hu, Jia-Sheng
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2003, 14 (03): : 288 - 291
  • [30] Polycapillary optics for soft X-ray imaging and tomography
    Pacella, D.
    Dabagov, S.
    Murtas, F.
    Romano, A.
    Hampai, D.
    Gabellieri, L.
    Mazon, D.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2011, 34 (04): : 513 - 520