Automatic alignment and reconstruction of images for soft X-ray tomography

被引:68
|
作者
Parkinson, Dilworth Y. [2 ]
Knoechel, Christian [1 ]
Yang, Chao [3 ]
Larabell, Carolyn A. [1 ,4 ]
Le Gros, Mark A. [4 ]
机构
[1] Univ Calif San Francisco, Dept Anat, San Francisco, CA 94143 USA
[2] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Adv Light Source, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Computat Res Div, Berkeley, CA 94720 USA
[4] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Phys Biosci Div, Berkeley, CA 94720 USA
关键词
3D imaging; Image processing; FIDUCIAL-LESS ALIGNMENT; MARKER-FREE ALIGNMENT; ORIENTATION REFINEMENT; ELECTRON; RESOLUTION; MICROSCOPY; VISUALIZATION; PACKAGE;
D O I
10.1016/j.jsb.2011.11.027
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Soft X-ray tomography (SXT) is a powerful imaging technique that generates quantitative, 3D images of the structural organization of whole cells in a near-native state. SXT is also a high-throughput imaging technique. At the National Center for X-ray Tomography (NCXT), specimen preparation and image collection for tomographic reconstruction of a whole cell require only minutes. Aligning and reconstructing the data, however, take significantly longer. Here we describe a new component of the high throughput computational pipeline used for processing data at the NCXT. We have developed a new method for automatic alignment of projection images that does not require fiducial markers or manual interaction with the software. This method has been optimized for SXT data sets, which routinely involve full rotation of the specimen. This software gives users of the NCXT SXT instrument a new capability - virtually real-time initial 3D results during an imaging experiment, which can later be further refined. The new code, Automatic Reconstruction 3D (AREC3D), is also fast, reliable, and robust. The fundamental architecture of the code is also adaptable to high performance GPU processing, which enables significant improvements in speed and fidelity. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:259 / 266
页数:8
相关论文
共 50 条
  • [1] Image Alignment for Tomography Reconstruction from Synchrotron X-Ray Microscopic Images
    Cheng, Chang-Chieh
    Chien, Chia-Chi
    Chen, Hsiang-Hsin
    Hwu, Yeukuang
    Ching, Yu-Tai
    PLOS ONE, 2014, 9 (01):
  • [2] Installation of soft X-ray array diagnostics and its application to tomography reconstruction using synthetic KSTAR X-ray images
    Lee, Seung Hun
    Jang, Juhyeok
    Hong, Joohwan
    Pacella, D.
    Romano, A.
    Gabellieri, L.
    Jang, Siwon
    Kim, Junghee
    Choe, Wonho
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [3] Automatic Parameter Tuning for X-ray Computed Tomography Reconstruction
    Liu, Li
    Lin, Weikai
    Jin, Mingwu
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [4] A reconstruction formula for soft tissue X-ray phase tomography
    Wu, Xizeng
    Liu, Hong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2004, 12 (04) : 273 - 279
  • [5] Fast automatic segmentation of anatomical structures in x-ray computed tomography images to improve fluorescence molecular tomography reconstruction
    Freyer, Marcus
    Ale, Angelique
    Schulz, Ralf B.
    Zientkowska, Marta
    Ntziachristos, Vasilis
    Englmeier, Karl-Hans
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (03)
  • [6] AUTOMATIC MASK ALIGNMENT FOR X-RAY MICROLITHOGRAPHY
    DOEMENS, G
    MENGEL, P
    SIEMENS FORSCHUNGS-UND ENTWICKLUNGSBERICHTE-SIEMENS RESEARCH AND DEVELOPMENT REPORTS, 1984, 13 (02): : 43 - 47
  • [7] Shape reconstruction in x-ray tomography
    MohammadDjafari, A
    IMAGE RECONSTRUCTION AND RESTORATION II, 1997, 3170 : 240 - 251
  • [8] Responsive alignment for X-ray tomography beamlines
    Querino de Vasconcelos, Gustavo Jose
    Miqueles, Eduardo Xavier
    Ruiz Costa, Gabriel Schubert
    JOURNAL OF SYNCHROTRON RADIATION, 2018, 25 : 1774 - 1779
  • [9] Characterization of small nodules by automatic segmentation of X-ray computed tomography images
    Tao, P
    Griess, F
    Lvov, Y
    Mineyev, M
    Zhao, BS
    Levin, D
    Kaufman, L
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (03) : 372 - 377
  • [10] Joint iterative reconstruction and 3D rigid alignment for X-ray tomography
    Pande, K.
    Donatelli, J. J.
    Parkinson, D. Y.
    Yan, H.
    Sethian, J. A.
    OPTICS EXPRESS, 2022, 30 (06) : 8898 - 8916