Automated 3-dimensional segmentation of pelvic lymph nodes in magnetic resonance images

被引:20
|
作者
Debats, O. A. [1 ]
Litjens, G. J. S. [1 ]
Barentsz, J. O. [1 ]
Karssemeijer, N. [1 ]
Huisman, H. J. [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, NL-6525 GA Nijmegen, Gelderland, Netherlands
关键词
CAD; segmentation; lymph node; USPIO; MR-lymphography; PROSTATE-CANCER; CT; METASTASES; REGISTRATION; REGIONS; NODULES; MODELS; HEAD; MRI;
D O I
10.1118/1.3654162
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Computer aided diagnosis (CAD) of lymph node metastases may help reduce reading time and improve interpretation of the large amount of image data in a 3-D pelvic MRI exam. The purpose of this study was to develop an algorithm for automated segmentation of pelvic lymph nodes from a single seed point, as part of a CAD system for the classification of normal vs metastatic lymph nodes, and to evaluate its performance compared to other algorithms. Methods: The authors' database consisted of pelvic MR images of 146 consecutive patients, acquired between January 2008 and April 2010. Each dataset included four different MR sequences, acquired after infusion of a lymph node specific contrast medium based on ultrasmall superparamagnetic particles of iron oxide. All data sets were analyzed by two expert readers who, reading in consensus, annotated and manually segmented the lymph nodes. The authors compared four segmentation algorithms: confidence connected region growing (CCRG), extended CCRG (ECC), graph cut segmentation (GCS), and a segmentation method based on a parametric shape and appearance model (PSAM). The methods were ranked based on spatial overlap with the manual segmentations, and based on diagnostic accuracy in a CAD system, with the experts' annotations as reference standard. Results: A total of 2347 manually annotated lymph nodes were included in the analysis, of which 566 contained a metastasis. The mean spatial overlap (Dice similarity coefficient) was: 0.35 (CCRG), 0.57 (ECC), 0.44 (GCS), and 0.46 (PSAM). When combined with the classification system, the area under the ROC curve was: 0.805 (CCRG), 0.890 (ECC), 0.807 (GCS), 0.891 (PSAM), and 0.935 (manual segmentation). Conclusions: We identified two segmentation methods, ECC and PSAM, that achieve a high diagnostic accuracy when used in conjunction with a CAD system for classification of normal vs metastatic lymph nodes. The manual segmentations still achieve the highest diagnostic accuracy. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3654162]
引用
收藏
页码:6178 / 6187
页数:10
相关论文
共 50 条
  • [41] DETERMINATION OF 3-DIMENSIONAL TORSO, HEART AND ELECTRODE GEOMETRIES FROM MAGNETIC-RESONANCE IMAGES
    ERSHLER, PR
    LUX, RL
    GREEN, LS
    CAPUTO, GR
    PARKER, D
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 121 - 122
  • [42] TRUE 3-DIMENSIONAL NUCLEAR MAGNETIC-RESONANCE ZEUGMATOGRAPHIC IMAGES OF A HUMAN-BRAIN
    KRAMER, DM
    SCHNEIDER, JS
    RUDIN, AM
    LAUTERBUR, PC
    NEURORADIOLOGY, 1981, 21 (05) : 239 - 244
  • [43] Development and validation of the 3D U-Net algorithm for segmentation of pelvic lymph nodes on diffusion-weighted images
    Xiang Liu
    Zhaonan Sun
    Chao Han
    Yingpu Cui
    Jiahao Huang
    Xiangpeng Wang
    Xiaodong Zhang
    Xiaoying Wang
    BMC Medical Imaging, 21
  • [44] Laryngeal Electromyography: Electrode Guidance Based on 3-Dimensional Magnetic Resonance Tomography Images of the Larynx
    Storck, Claudio
    Gehrer, Raphael
    Hofer, Michael
    Neumayer, Bernhard
    Stollberger, Rudolf
    Schumacher, Ralf
    Gugatschka, Markus
    Friedrich, Gerhard
    Wolfensberger, Markus
    JOURNAL OF VOICE, 2012, 26 (01) : 110 - 116
  • [46] Automated Heart Localization for the Segmentation of the Ventricular Cavities on Cine Magnetic Resonance Images
    Constantinides, C.
    Chenoune, Y.
    Mousseaux, E.
    Roullot, E.
    Frouin, F.
    COMPUTING IN CARDIOLOGY 2010, VOL 37, 2010, 37 : 911 - 914
  • [47] The accuracy of 3-dimensional magnetic resonance 3D vibe images of the mandible: an in vitro comparison of magnetic resonance imaging and computed tomography
    Goto, Tazuko K.
    Nishida, Satoko
    Nakamura, Yuko
    Tokumori, Kenji
    Nakamura, Yasuhiko
    Kobayashi, Koji
    Yoshida, Yutaka
    Yoshiura, Kazunori
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 103 (04): : 550 - 559
  • [48] Automated Bone Segmentation from Pelvic CT Images
    Vasilache, Simina
    Najarian, Kayvan
    2008 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICINE WORKSHOPS, PROCEEDINGS, 2008, : 41 - 47
  • [49] Automated Segmentation of In Vivo and Ex Vivo Mouse Brain Magnetic Resonance Images
    Scheenstra, Alize E. H.
    van de Ven, Rob C. G.
    van der Weerd, Louise
    van den Maagdenberg, Arn M. J. M.
    Dijkstra, Jouke
    Reiber, Johan H. C.
    MOLECULAR IMAGING, 2009, 8 (01): : 35 - 44
  • [50] Modified Watershed Transform for Automated Brain Segmentation from Magnetic Resonance Images
    Roshanzadeh, Siamak
    Afrakhteh, Masoud
    ICCCV 2019: PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON CONTROL AND COMPUTER VISION, 2019, : 60 - 65