A New Approach for Transient Response Control via Characteristic Ratio Assignment Method

被引:6
|
作者
Kang, Yoon-Bok [2 ]
Rho, Hian [1 ]
Kim, Hansil [1 ]
机构
[1] Univ Ulsan, Sch Elect Engn, Ulsan 680749, South Korea
[2] Capro Ltd, Maintenance Dept, Ulsan, South Korea
关键词
Characteristic ratio; Newton expansion; overshoot; repeated-pole system; transient response;
D O I
10.1007/s12555-011-0406-x
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper proposes a new direct approach to control the transient response of a LTI system. The characteristic of a repeated-pole system is first studied. It can be shown that the step response of this kind of system has no overshoot. mu-scaled characteristic ratios, beta(i) = mu alpha(i,) i = 1, ... n, and tau are introduced, where alpha(i) is the principal characteristic ratio and tau is the generalized time constant. It is shown that two parameters, mu and tau, are used to successfully control the overshoot and the transient time of all minimum phase LTI systems. The result shows that the proposed method is comparable to the method proposed by Bhattacharyya [I], but more luminous and simple in approach.
引用
收藏
页码:659 / 664
页数:6
相关论文