Tracheal intubation of morbidly obese patients:: a randomized trial comparing performance of Macintosh and Airtraq™ laryngoscopes

被引:95
|
作者
Ndoko, S. K. [1 ]
Amathieu, R. [1 ,3 ]
Tual, L. [1 ]
Polliand, C. [2 ]
Kamoun, W. [1 ]
El Housseini, L. [1 ]
Champault, G. [2 ,3 ]
Dhonneur, G. [1 ]
机构
[1] Jean Verdier Publ Univ Hosp Paris, APHP, Dept Anaesthesia & Intens Care, F-93143 Bondy, France
[2] Jean Verdier Publ Univ Hosp Paris, APHP, Visceral & Obes Surg Dept, F-93143 Bondy, France
[3] Paris 13 Sch Med, F-93000 Bobigny, France
关键词
airway; equipment; laryngoscope; oxygen; therapy;
D O I
10.1093/bja/aem346
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. The Airtraq(TM) laryngoscope is designed to allow visualization of the glottis without alignment of the oral, pharyngeal, and laryngeal axes. We hypothesized that this new airway device would facilitate tracheal intubation of morbidly obese patients. We compared tracheal intubation performance of standard Macintosh laryngoscope with the Airtraq(TM) laryngoscope in morbidly obese patients. Methods. One hundred and six consecutive ASA I-III morbidly obese patients undergoing surgery were randomized to intubation with the Macintosh laryngoscope or the Airtraq(TM) laryngoscope. Induction of anaesthesia was standardized. If tracheal intubation failed within 120 s with the Macintosh or Airtraq(TM) , laryngoscopes were switched. Success rate, SpO(2), duration of tracheal intubation, and quality of airway management were evaluated and compared between the groups. Results. Preoperative characteristics of the patients were similar in both groups. In the Airtraq(TM) group, tracheal intubation was successfully carried out in all patients within 120 s. In the Macintosh laryngoscope group, six patients required intubation with the Airtraq(TM) laryngoscope. The mean (SD) time taken for tracheal intubation was 24 (16) and 56 (23) s, respectively, with the Airtraq(TM) and Macintosh laryngoscopes, (P < 0.001). SpO(2) was better maintained in the Airtraq(TM) group than in the Macintosh laryngoscope group with one and nine patients, respectively, demonstrating drops of SpO(2) to 92% or less (P < 0.05). Conclusions. In this study, the Airtraq(TM) laryngoscope shortened the duration of tracheal intubation and prevented reductions in arterial oxygen saturation in morbidly obese patients.
引用
收藏
页码:263 / 268
页数:6
相关论文
共 50 条
  • [31] Intubation Biomechanics Laryngoscope Force and Cervical Spine Motion during Intubation with Macintosh and Airtraq Laryngoscopes
    Hindman, Bradley J.
    Santoni, Brandon G.
    Puttlitz, Christian M.
    From, Robert P.
    Todd, Michael M.
    ANESTHESIOLOGY, 2014, 121 (02) : 260 - 271
  • [32] Comparison of the Laryngeal View during Tracheal Intubation Using Airtraq and Macintosh Laryngoscopes by Unskillful Anesthesiology Residents: A Clinical Study
    Ferrando, Carlos
    Aguilar, Gerardo
    Javier Belda, F.
    ANESTHESIOLOGY RESEARCH AND PRACTICE, 2011, 2011
  • [33] A comparison of face-to-face endotracheal intubation and standard intubation using Airtraq video laryngoscope in morbidly obese patients: A randomized controlled trial
    Nowak-Tim, Justyna
    Gaszynski, Tomasz
    Ratajczyk, Pawel
    MEDICINE, 2022, 101 (48) : E32046
  • [34] Tracheal intubation by anesthesiology medical residents comparing Airtraq® with the Macintosh laryngoscope - a prospective study on mannequins
    de Magalhaes, Paula Macedo Coelho
    Simoes, Claudia Marques
    Cohen, Claudia Panossian
    De Menezes, Cassio Campelo
    Silva, Enis Donizetti
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 : 140 - 140
  • [35] A randomized controlled trial comparing Macintosh laryngoscope and Airtraq video laryngoscope for endotracheal intubation in patients with thyroid swelling: Competing the convention
    Singh, Pratibha
    Srivastava, Vinod
    Gautam, Shefali
    Malik, Anita
    Kohli, Monica
    Agarwal, Jyotsna
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2022, 11 (07) : 3699 - 3704
  • [36] McGrath® versus Macintosh laryngoscopes on hemodynamic response to intubation in elderly patients: a randomized clinical trial
    Ketata, Salma
    Fourati, Mahdi
    Derbel, Rahma
    Keskes, Mariem
    Bouzid, Karim
    Zouche, Imen
    Sallemi, Moncef
    Kallel, Souha
    Fendri, Sami
    Zouari, Amine
    Cheikhrouhou, Hichem
    PAN AFRICAN MEDICAL JOURNAL, 2023, 45
  • [37] A randomized crossover trial comparing the C-MAC and Macintosh laryngoscopes for face-to-face intubation in a manikin
    Szarpak, Lukasz
    Truszewski, Zenon
    Galazkowski, Robert
    Evrin, Togay
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (05): : 920 - 922
  • [38] Intubation with Airtraq (TM) laryngoscope in a morbidly obese patient
    Tantia, Pratik
    Malik, Sunny
    Jamil, Shahin
    Samal, Rajiv
    SAUDI JOURNAL OF ANAESTHESIA, 2011, 5 (01) : 85 - 86
  • [39] A comparison of McCoy, TruView, and Macintosh laryngoscopes for tracheal intubation in patients with immobilized cervical spine
    Bharti, Neerja
    Arora, Suman
    Panda, Nidhi B.
    SAUDI JOURNAL OF ANAESTHESIA, 2014, 8 (02) : 188 - 192
  • [40] Randomized controlled trial of the Pentax AWS®, Glidescope®, and Macintosh laryngoscopes in predicted difficult intubation
    Malik, M. A.
    Subramaniam, R.
    Maharaj, C. H.
    Harte, B. H.
    Laffey, J. G.
    BRITISH JOURNAL OF ANAESTHESIA, 2009, 103 (05) : 761 - 768