Tracheal intubation of morbidly obese patients:: a randomized trial comparing performance of Macintosh and Airtraq™ laryngoscopes

被引:95
|
作者
Ndoko, S. K. [1 ]
Amathieu, R. [1 ,3 ]
Tual, L. [1 ]
Polliand, C. [2 ]
Kamoun, W. [1 ]
El Housseini, L. [1 ]
Champault, G. [2 ,3 ]
Dhonneur, G. [1 ]
机构
[1] Jean Verdier Publ Univ Hosp Paris, APHP, Dept Anaesthesia & Intens Care, F-93143 Bondy, France
[2] Jean Verdier Publ Univ Hosp Paris, APHP, Visceral & Obes Surg Dept, F-93143 Bondy, France
[3] Paris 13 Sch Med, F-93000 Bobigny, France
关键词
airway; equipment; laryngoscope; oxygen; therapy;
D O I
10.1093/bja/aem346
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. The Airtraq(TM) laryngoscope is designed to allow visualization of the glottis without alignment of the oral, pharyngeal, and laryngeal axes. We hypothesized that this new airway device would facilitate tracheal intubation of morbidly obese patients. We compared tracheal intubation performance of standard Macintosh laryngoscope with the Airtraq(TM) laryngoscope in morbidly obese patients. Methods. One hundred and six consecutive ASA I-III morbidly obese patients undergoing surgery were randomized to intubation with the Macintosh laryngoscope or the Airtraq(TM) laryngoscope. Induction of anaesthesia was standardized. If tracheal intubation failed within 120 s with the Macintosh or Airtraq(TM) , laryngoscopes were switched. Success rate, SpO(2), duration of tracheal intubation, and quality of airway management were evaluated and compared between the groups. Results. Preoperative characteristics of the patients were similar in both groups. In the Airtraq(TM) group, tracheal intubation was successfully carried out in all patients within 120 s. In the Macintosh laryngoscope group, six patients required intubation with the Airtraq(TM) laryngoscope. The mean (SD) time taken for tracheal intubation was 24 (16) and 56 (23) s, respectively, with the Airtraq(TM) and Macintosh laryngoscopes, (P < 0.001). SpO(2) was better maintained in the Airtraq(TM) group than in the Macintosh laryngoscope group with one and nine patients, respectively, demonstrating drops of SpO(2) to 92% or less (P < 0.05). Conclusions. In this study, the Airtraq(TM) laryngoscope shortened the duration of tracheal intubation and prevented reductions in arterial oxygen saturation in morbidly obese patients.
引用
收藏
页码:263 / 268
页数:6
相关论文
共 50 条
  • [1] Comparing the Intubation Performance of Macintosh and Airtraq Laryngoscopes
    Sun, Chao
    Xue, Fu-Shan
    Liu, Gao-Pu
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2017, 29 (01) : 69 - 70
  • [2] Comparison of the macintosh and airtraq laryngoscopes in morbidly obese patients: a randomized and prospective study
    Castillo-Monzon, Caridad G.
    Marroquin-Valz, Hugo A.
    Fernandez-Villacanas-Marin, Miguel
    Moreno-Cascales, Matilde
    Garcia-Rojo, Blas
    Candia-Arana, Cesar A.
    JOURNAL OF CLINICAL ANESTHESIA, 2017, 36 : 136 - 141
  • [3] Evaluation of the Airtraq® and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation
    Maharaj, C. H.
    Costello, J. F.
    Harte, B. H.
    Laffey, J. G.
    ANAESTHESIA, 2008, 63 (02) : 182 - 188
  • [4] Airtraq, LMA CTrach and Macintosh Laryngoscopes in Tracheal Intubation Training: A Randomized Comparative Manikin Study
    Saracoglu, Ayten
    Dal, Didem
    Baygin, Omer
    Gogus, Fevzi Yilmaz
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2016, 44 (02) : 76 - 80
  • [5] Comparison of ETView SL, Airtraq, and Macintosh laryngoscopes for face-to-face tracheal intubation: a randomized crossover manikin trial
    Madziala, Agnieszka
    Majer, Jolanta
    Madziala, Marcin
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (09): : 1893 - 1894
  • [6] Retention of tracheal intubation skills by novice personnel:: a comparison of the Airtraq® and Macintosh laryngoscopes
    Maharaj, C. H.
    Costello, J.
    Higgins, B. D.
    Harte, B. H.
    Laffey, J. G.
    ANAESTHESIA, 2007, 62 (03) : 272 - 278
  • [7] Comparing performance of Macintosh and Intubrite laryngoscopes for intubation
    Jin, Jin-Hua
    Xue, Fu-Shan
    Li, Hui-Xian
    Liu, Ya-Yang
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2017, 35 (06): : 924 - 925
  • [8] A Comparison of Miller Straight Blade and Macintosh Blade Laryngoscopes for Intubation in Morbidly Obese Patients
    Ratajczyk, Pawel
    Kluj, Przemyslaw
    Szmyd, Bartosz
    Resch, Julia
    Hogendorf, Piotr
    Durczynski, Adam
    Gaszynski, Tomasz
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (03)
  • [9] Tracheal intubation by inexperienced medical residents using the Airtraq and Macintosh laryngoscopes - a manikin study
    Maharaj, Chrisen H.
    Chonghaile, Martina Ni
    Higgins, Brendan D.
    Harte, Brian H.
    Laffey, John G.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2006, 24 (07): : 769 - 774
  • [10] Comparison of the Macintosh and Airtraq Laryngoscopes in Endotracheal Intubation Success
    Erturk, Tuna
    Deniz, Suleyman
    Simsek, Fatih
    Purtuloglu, Tarik
    Kurt, Ercan
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2015, 43 (03) : 181 - 187