Efficacy and safety data for the Ab interno XEN45 gel stent implant at 3 Years: A retrospective analysis

被引:21
|
作者
Gabbay, Itay E. [1 ,2 ,3 ]
Goldberg, Mordechai [1 ]
Allen, Felicity [1 ]
Lin, Zhiheng [1 ]
Morley, Christine [1 ]
Pearsall, Tahmina [4 ]
Muraleedharan, Veena [1 ]
Ruben, Simon [1 ]
机构
[1] Mid & South Essex NHS Fdn Trust, Dept Ophthalmol, Southend On Sea, England
[2] Beilinson Med Ctr, Rabin Med Ctr, Petah Tiqwa, Israel
[3] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[4] Whipps Cross Univ Hosp, Barts Hlth NHS Trust, London, England
关键词
XEN; glaucoma; minimally invasive; open angle; surgery; OPEN-ANGLE GLAUCOMA; INTRAOCULAR-PRESSURE; SURGICAL-TREATMENT; SURGERY; PHACOEMULSIFICATION; VISCODILATION; MICROSTENT; REDUCTION; CATARACT; OUTCOMES;
D O I
10.1177/11206721211014381
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To report efficacy and safety measures of the XEN45 gel stent at 36 months in the UK National Health Service setting. Methods: Retrospective non-comparative audit of the records of patients who underwent XEN45 implantation between June 2015 and May 2017 was performed. Main outcome measures were intraocular pressure and number of antihypertensive medications used. Failure was defined as need for further surgery or stent removal. Success was defined as a 20% decrease in intraocular pressure without the need for additional glaucoma medications or a reduction in antihypertensive medications without an increase in baseline intraocular pressure. Needling rates and preoperative factors effect were assessed. Results: The cohort included 205 patients (205 eyes) with primary open angle glaucoma (84.4%), angle closure glaucoma (7.8%), or refractory glaucoma (7.8%), 62.9% had a stand-alone procedure and 37.1%, a combined phaco-XEN45 procedure. Mean intraocular pressure was 22.6 +/- 7.0 mmHg at baseline compared to 14.7 +/- 3.8 mmHg at 24 months and 14.0 +/- 2.9 mmHg at 36 months (p < 0.001 for both). Mean number of medications used was 2.6 +/- 1.1 at baseline compared to 0.5 +/- 0.9 and 0.6 +/- 1.0, at 24- and 36-months, respectively (p < 0.001 for both). The failure rate at 36 months was 25%. Needling was required in 36.6%. Evaluation of background factors yielded an increased failure rate in non-Caucasians compared to Caucasians (74% vs 21%, p < 0.001). Conclusion: XEN45 implantation is effective and safe at 36 months' follow-up. Patients should be advised regarding the risk of failure and possible need for bleb revisions. Careful patient selection may be required.
引用
收藏
页码:1016 / 1022
页数:7
相关论文
共 50 条
  • [21] Letter to the Editor: Short-Term Efficacy and Safety of Open Conjunctiva Ab Externo XEN45 Gel Stent Implantation in Glaucoma Patients
    Arora, Charu
    Tayab, Shahinur
    Bhattacharjee, Harsha
    Gogoi, Dollytutu
    Sah, Nikita
    JOURNAL OF GLAUCOMA, 2023, 32 (04) : E36 - E36
  • [22] Glaucoma medical treatment as a predictor of XEN45 subconjunctival gel implant hypotensive efficacy
    Carmen Méndez-Hernández
    Carlos Palomino-Bautista
    Ramón Torres-Imaz
    Pilar Peña-Urbina
    Lucía Perucho-González
    Julián García-Feijoo
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2023, 261 : 521 - 533
  • [23] Glaucoma medical treatment as a predictor of XEN45 subconjunctival gel implant hypotensive efficacy
    Mendez-Hernandez, Carmen
    Palomino-Bautista, Carlos
    Torres-Imaz, Ramon
    Pena-Urbina, Pilar
    Perucho-Gonzalez, Lucia
    Garcia-Feijoo, Julian
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (02) : 521 - 533
  • [24] Three-years effectiveness and safety of XEN45 implant: data from the Italian XEN Glaucoma Treatment Registry.
    Giammaria, Sara
    Figus, Michele
    Roberti, Gloria
    Posarelli, Chiara
    Mastropasqua, Leonardo
    Agnifili, Luca
    Ferrari, Tommaso Micelli
    Pace, Vincenzo
    Sacchi, Matteo
    Altafini, Romeo
    Scuderi, Gianluca
    Perdicchi, Andrea
    Carnevale, Carmela
    Fea, Antonio
    Oddone, Francesco
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [25] Outcomes of XEN45 gel stent using posterior small incision sub-tenon ab interno insertion (Semi-open) technique
    Yu Xiang George Kong
    In Young Chung
    Ghee Soon Ang
    Eye, 2022, 36 : 1456 - 1460
  • [26] Outcomes of XEN45 gel stent using posterior small incision sub-tenon ab interno insertion (Semi-open) technique
    Kong, Yu Xiang George
    Chung, In Young
    Ang, Ghee Soon
    EYE, 2022, 36 (07) : 1456 - 1460
  • [27] One-year result of XEN45 implant for glaucoma: efficacy, safety, and postoperative management
    S Z Tan
    A Walkden
    L Au
    Eye, 2018, 32 : 324 - 332
  • [28] One-year result of XEN45 implant for glaucoma: efficacy, safety, and postoperative management
    Tan, S. Z.
    Walkden, A.
    Au, L.
    EYE, 2018, 32 (02) : 324 - 332
  • [29] Short-Term Outcomes of Xen-45 Gel Stent Ab Interno Versus Ab Externo Transconjunctival Approaches
    Yuan, Lucy
    Rana, Harkaran S.
    Lee, Ian
    Lai, Gregory
    Raiciulescu, Sorana
    Kim, Won
    JOURNAL OF GLAUCOMA, 2023, 32 (07) : E71 - E79