Efficacy and safety data for the Ab interno XEN45 gel stent implant at 3 Years: A retrospective analysis

被引:21
|
作者
Gabbay, Itay E. [1 ,2 ,3 ]
Goldberg, Mordechai [1 ]
Allen, Felicity [1 ]
Lin, Zhiheng [1 ]
Morley, Christine [1 ]
Pearsall, Tahmina [4 ]
Muraleedharan, Veena [1 ]
Ruben, Simon [1 ]
机构
[1] Mid & South Essex NHS Fdn Trust, Dept Ophthalmol, Southend On Sea, England
[2] Beilinson Med Ctr, Rabin Med Ctr, Petah Tiqwa, Israel
[3] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[4] Whipps Cross Univ Hosp, Barts Hlth NHS Trust, London, England
关键词
XEN; glaucoma; minimally invasive; open angle; surgery; OPEN-ANGLE GLAUCOMA; INTRAOCULAR-PRESSURE; SURGICAL-TREATMENT; SURGERY; PHACOEMULSIFICATION; VISCODILATION; MICROSTENT; REDUCTION; CATARACT; OUTCOMES;
D O I
10.1177/11206721211014381
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To report efficacy and safety measures of the XEN45 gel stent at 36 months in the UK National Health Service setting. Methods: Retrospective non-comparative audit of the records of patients who underwent XEN45 implantation between June 2015 and May 2017 was performed. Main outcome measures were intraocular pressure and number of antihypertensive medications used. Failure was defined as need for further surgery or stent removal. Success was defined as a 20% decrease in intraocular pressure without the need for additional glaucoma medications or a reduction in antihypertensive medications without an increase in baseline intraocular pressure. Needling rates and preoperative factors effect were assessed. Results: The cohort included 205 patients (205 eyes) with primary open angle glaucoma (84.4%), angle closure glaucoma (7.8%), or refractory glaucoma (7.8%), 62.9% had a stand-alone procedure and 37.1%, a combined phaco-XEN45 procedure. Mean intraocular pressure was 22.6 +/- 7.0 mmHg at baseline compared to 14.7 +/- 3.8 mmHg at 24 months and 14.0 +/- 2.9 mmHg at 36 months (p < 0.001 for both). Mean number of medications used was 2.6 +/- 1.1 at baseline compared to 0.5 +/- 0.9 and 0.6 +/- 1.0, at 24- and 36-months, respectively (p < 0.001 for both). The failure rate at 36 months was 25%. Needling was required in 36.6%. Evaluation of background factors yielded an increased failure rate in non-Caucasians compared to Caucasians (74% vs 21%, p < 0.001). Conclusion: XEN45 implantation is effective and safe at 36 months' follow-up. Patients should be advised regarding the risk of failure and possible need for bleb revisions. Careful patient selection may be required.
引用
收藏
页码:1016 / 1022
页数:7
相关论文
共 50 条
  • [1] Efficacy and safety data for the XEN45 implant at 2 years: a retrospective analysis
    Gabbay, Itay Elimelech
    Allen, Felicity
    Morley, Christine
    Pearsall, Tahmina
    Bowes, Oliver Martyn
    Ruben, Simon
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (08) : 1125 - 1130
  • [2] Xen45 gel stent ab interno trimming for ostium occlusion: case report
    Tatti, Filippo
    Gentile, Pietro
    Mangoni, Lorenzo
    Demarinis, Giuseppe
    Napoli, Pietro
    Fossarello, Maurizio
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [3] Xen45 gel stent ab interno trimming for ostium occlusion: case report
    Filippo Tatti
    Pietro Gentile
    Lorenzo Mangoni
    Giuseppe Demarinis
    Pietro Napoli
    Maurizio Fossarello
    BMC Ophthalmology, 21
  • [4] Safety and Efficacy of Ab Interno XEN 45 Gel Stent in Patients with Glaucoma and High Myopia
    Sacchi, Matteo
    Fea, Antonio M.
    Monsellato, Gianluca
    Tagliabue, Elena
    Villani, Edoardo
    Ranno, Stefano
    Nucci, Paolo
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (07)
  • [5] Xen45 Gel Stent implant: patient reported outcomes
    Faaiq Hassan
    Luke Thomas Middleton Thomson
    Gurpal Toor
    Qusay Alfahad
    International Journal of Ophthalmology, 2019, (09) : 1503 - 1506
  • [6] Xen45 Gel Stent implant: patient reported outcomes
    Hassan, Faaiq
    Thomson, Luke Thomas Middleton
    Toor, Gurpal
    Alfahad, Qusay
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2019, 12 (09) : 1503 - 1506
  • [7] Swiss Multicenter Ab Interno XEN45 Gel Stent Study: 2-Year Real-World Data
    Papazoglou, Anthia
    Hoehn, Rene
    Schawkat, Megir
    Tappeiner, Christoph
    Iliev, Milko
    Gugleta, Konstantin
    Saletta, Giulia
    Wiencierz, Andrea
    Wagels, Barbara
    Todorova, Margarita G.
    Krzyzanowska, Iwona
    Toeteberg-Harms, Marc
    Tschopp, Markus
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (06) : 1513 - 1525
  • [8] Efficacy and Safety of the Ab-interno Xen Gel Stent After Failed Trabeculectomy
    Karimi, Ayesha
    Hopes, Marina
    Martin, Keith R.
    Lindfield, Dan
    JOURNAL OF GLAUCOMA, 2018, 27 (10) : 864 - 868
  • [9] XEN45 Gel Stent Combined with Healaflow Injectable Viscoelastic Implant
    Villarreal, Eloy
    Berkowitz, Eran
    Tiosano, Beatrice
    CASE REPORTS IN OPHTHALMOLOGICAL MEDICINE, 2023, 2023
  • [10] Impact of failed ab-interno trabeculectomy (trabectome) on subsequent XEN45 gel stent implantation in pseudophakic eyes
    Kiessling, D.
    Rennings, C.
    Hild, M.
    Lappas, A.
    Dietlein, T. S.
    Roessler, G. F.
    Widder, Randolf Alexander
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (12) : 4047 - 4053