EFFECT OF THE TIP CLEARANCE ON END WALL HEAT-TRANSFER IN A HP TURBINE

被引:0
|
作者
Biester, Marc H. -O. [1 ]
Karapetrow, Dimitri [1 ]
Seume, Joerg R. [1 ]
机构
[1] Leibniz Univ Hannover, Inst Turbomachinery & Fluid Dynam, D-30167 Hannover, Germany
关键词
LEAKAGE FLOW;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The present investigation analyzes the effect of the extension of the radial gap on the heat transfer at the blade tip and the casing within a high-pressure turbine stage of an aircraft engine. Due to the rotation and the interaction of the adjacent bladerows, the flow field in the tip region of an unshrouded rotorblade is characterized by a high level of unsteadiness. Furthermore, the casing is exposed to the passing blade-gap and corresponding changes in the velocity-profile, the resulting near-wall velocity-gradients, and the resulting changes in heat transfer In order to account for these effects, time-resolved RANS computations of three different radial gaps are performed and evaluated. The present analysis shows an influence of the radial gap on the characteristics of the steady and unsteady heat transfer and a correlation with the size of the tip-clearance vortex can be shown.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Effects of Tip Clearance Gap and Exit Mach Number on Turbine Blade Tip and Near-Tip Heat Transfer
    Anto, K.
    Xue, S.
    Ng, W. F.
    Zhang, L. J.
    Moon, H. K.
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2013, VOL 3C, 2013,
  • [22] HEAT-TRANSFER AND SHEAR-STRESS AT THE END WALL OF A VORTEX CHAMBER
    VOLCHKOV, EP
    SEMENOV, SV
    TEREKOV, VI
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1991, 4 (05) : 546 - 557
  • [23] Effects of rim location, rim height, and tip clearance on the tip and near tip region heat transfer of a gas turbine blade
    Kwak, JS
    Ahn, JY
    Han, JC
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (26) : 5651 - 5663
  • [24] EFFECT OF TURBINE BLADE TIP COOLING CONFIGURATION ON TIP LEAKAGE FLOW AND HEAT TRANSFER
    Sakaoglu, Sergen
    Kahveci, Harika S.
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, 2019, VOL 5A, 2019,
  • [25] Effect of Turbine Blade Tip Cooling Configuration on Tip Leakage Flow and Heat Transfer
    Sakaoglu, Sergen
    Kahveci, Harika S.
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2020, 142 (02):
  • [26] EFFECT OF A MOVING PARTICLE ON WALL HEAT-TRANSFER IN A CHANNEL FLOW
    KAVIANY, M
    NUMERICAL HEAT TRANSFER, 1988, 13 (01): : 111 - 124
  • [27] END-WALL HEAT-TRANSFER EFFECTS ON THE TRAJECTORY OF A REFLECTED SHOCK WAVE
    STURTEVANT, B
    SLACHMUYLDERS, E
    PHYSICS OF FLUIDS, 1964, 7 (08) : 1201 - 1207
  • [28] Effects of tip geometry and tip clearance on the mass/heat transfer from a large-scale gas turbine blade
    Papa, M
    Goldstein, RJ
    Gori, F
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2003, 125 (01): : 90 - 96
  • [29] WALL HEAT-TRANSFER TO CHEMICAL REACTORS
    CHAO, RE
    CABAN, RA
    IRIZARRY, MM
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1973, 51 (01): : 67 - 70
  • [30] AN INVESTIGATION OF THE EFFECT OF TEMPERATURE UNSTEADINESS ON HEAT-TRANSFER TO TURBINE-BLADES
    PANTELEEV, AA
    SLESAREV, VA
    TRUSHIN, VA
    THERMAL ENGINEERING, 1981, 28 (10) : 612 - 615