HPLC and LC-MS/MS measurement methods for the quantification of asymmetric dimethylarginine (ADMA) and related metabolites

被引:5
|
作者
Unlu, Ali [1 ]
Onmaz, Duygu Eryavuz [1 ]
Abusoglu, Sedat [1 ]
Abusoglu, Gulsum [2 ]
机构
[1] Selcuk Univ, Dept Biochem, Fac Med, TR-42075 Konya, Turkey
[2] Selcuk Univ Vocat, Dept Med Lab Tech, Sch Hlth, Konya, Turkey
关键词
chromatography; methodology; methylated arginine; nitric oxide; tandem mass spectrometry; PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; DIMETHYLATED ARGININE DERIVATIVES; NITRIC-OXIDE SYNTHASE; HUMAN PLASMA; SYMMETRIC DIMETHYLARGININE; BIOLOGICAL SAMPLES; METHYLATED ARGININES; HUMAN URINE; TARGETED METABOLOMICS;
D O I
10.1515/tjb-2020-0150
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Methyl arginine derivatives such as asymmetric dimethylarginine (ADMA), symmetric dimethylarginine (SDMA), L-N-monomethyl arginine (L-NMMA) are formed by proteolytic catalysis following methylation of arginine residues in proteins. These metabolites reduce NO production. Methylated arginines are an important biomarker for various diseases such as cardiovascular and renal diseases. Therefore, many methods have been developed to reliably and accurately measure the levels of these metabolites. This review, HPLC and LC-MS/MS methods developed for the measurement of methylarginine derivatives are discussed. In HPLC methods, solid phase extraction, derivatization and subsequent separation by reverse phase chromatography were performed. Since these metabolites are polar, they are difficult to retain in conventional reverse phase columns. In addition, as serum levels of these metabolites are low, sensitivity problems have been observed in HPLC methods. Derivatization has been applied to eliminate these problems. However, there have been problems with the stability of derivatives formed. Another important problem is that the separation of stereoisomer ADMA and SDMA can only be achieved chromatographically. Tandem mass spectrometric methods are accurate, selective, sensitive and rapid since analytes are separated depending on m/z ratios rather than chromatographic separation. Therefore, tandem mass spectrometry methods might be considered as the goal standard for these analytes.
引用
收藏
页码:327 / 347
页数:21
相关论文
共 50 条
  • [41] Drugs of abuse quantification using LC-MS/MS
    Gauthier, Jeannette
    Petryayeva, Eleonora
    Nichols, Matthew
    Macri, Joseph
    Potter, Murray
    CLINICAL BIOCHEMISTRY, 2020, 86 : 80 - 80
  • [42] Quantification of vancomycin in human serum by LC-MS/MS
    Koenig, Katrin
    Kobold, Uwe
    Fink, Gerhard
    Leinenbach, Andreas
    Duelffer, Thomas
    Thiele, Roland
    Zander, Johannes
    Vogeser, Michael
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (09) : 1761 - 1769
  • [43] Comparison of three quantification approaches for LC-MS/MS
    Lehotay, Steven J.
    Mastovska, Katerina
    Lightfield, Alan R.
    Gates, Robert A.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U226 - U227
  • [44] LC-MS/MS-MS3 for the determination and quantification of Δ9-tetrahydrocannabinol and metabolites in blood samples
    Proenca, Paula
    Teixeira, Helena M.
    Martinho, Beatriz
    Monteiro, Carla
    Franco, Joao
    Corte-Real, Francisco
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2023, : 606 - 614
  • [45] Development and validation of an LC-MS/MS method for the quantification of mescaline and major metabolites in human plasma
    Thomann, Jan
    Ley, Laura
    Klaiber, Aaron
    Liechti, Matthias E.
    Duthaler, Urs
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 220
  • [46] Highly sensitive simultaneous quantification of estrogenic tamoxifen metabolites and steroid hormones by LC-MS/MS
    Janina Johänning
    Georg Heinkele
    Jana C. Precht
    Hiltrud Brauch
    Michel Eichelbaum
    Matthias Schwab
    Werner Schroth
    Thomas E. Mürdter
    Analytical and Bioanalytical Chemistry, 2015, 407 : 7497 - 7502
  • [47] Simultaneous quantification of niacin and its three main metabolites in human plasma by LC-MS/MS
    Liu, Man
    Zhang, Dan
    Wang, Xiaolin
    Zhang, Lina
    Han, Jing
    Yang, Man
    Xiao, Xue
    Zhang, Yanan
    Liu, Huichen
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 904 : 107 - 114
  • [48] LC-MS/MS-based quantification of tryptophan metabolites and neurotransmitters in the serum and brain of mice
    Wang, Li-Sha
    Zhang, Meng-Di
    Tao, Xue
    Zhou, Yun-Feng
    Liu, Xin-Min
    Pan, Rui-Le
    Liao, Yong-Hong
    Chang, Qi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1112 : 24 - 32
  • [49] Highly sensitive simultaneous quantification of estrogenic tamoxifen metabolites and steroid hormones by LC-MS/MS
    Johaenning, Janina
    Heinkele, Georg
    Precht, Jana C.
    Brauch, Hiltrud
    Eichelbaum, Michel
    Schwab, Matthias
    Schroth, Werner
    Muerdter, Thomas E.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (24) : 7497 - 7502
  • [50] Targeted Metabolomics: The LC-MS/MS Based Quantification of the Metabolites Involved in the Methylation Biochemical Pathways
    Ntasi, Georgia
    Tsarbopoulos, Anthony
    Mikros, Emmanuel
    Gikas, Evagelos
    METABOLITES, 2021, 11 (07)