The determination of selenium in solid materials related with the use of coal for energy production was evaluated by two methods; ICP-MS and HG-ICP-MS. Coals, fly ashes and various solids used as sorbents in gas cleaning processes (kaolin, limestone, alumina, metal oxide mixtures and activated carbons), were the materials analysed. In several of these materials, selenium could be determined by either method with similar results. However in coal, fly ashes and some activated carbons, the use of a HG-ICP-MS is necessary in order to avoid interferences. The results obtained by both methods in samples whose selenium content ranges from mug g(-1) to mg g(-1), are discussed. In general, good (+/-2-4%) to excellent (+/-1-2%) agreement between the reference and the obtained concentrations was achieved in the analysis of the certified and reference samples, the relative standard deviation being lower than 10% in all cases. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:231 / 235
页数:5
相关论文
共 50 条
  • [31] ICP-MS speciation analysis: Three roles of selenium
    Cafferky, KO
    Richardson, DD
    Caruso, JA
    SPECTROSCOPY, 2006, 21 (02) : 18 - +
  • [33] ICP-MS Determination of Antimicrobial Metals in Microcapsules
    Rezic, Iva
    Skoc, Maja Somogyi
    Majdak, Mislav
    Juric, Slaven
    Stracenski, Katarina Sopko
    Vlahovicek-Kahlina, Kristina
    Vincekovic, Marko
    MOLECULES, 2022, 27 (10):
  • [34] Determination of neptunium in plutonium materials by ICP-MS
    Xu, N.
    Gallimore, D.
    Martinez, A.
    Townsend, L.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 297 (01) : 127 - 132
  • [35] Determination of neptunium in plutonium materials by ICP-MS
    N. Xu
    D. Gallimore
    A. Martinez
    L. Townsend
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 297 : 127 - 132
  • [36] Determination of uranium in tap water by ICP-MS
    El Himri, M
    Pastor, A
    de la Guardia, M
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (02): : 151 - 156
  • [37] Development of analytical procedures for determination of total chromium by quadrupole ICP-MS and high-resolution ICP-MS, and hexavalent chromium by HPLC-ICP-MS, in different materials used in the automotive industry
    Séby, F
    Gagean, M
    Garraud, H
    Castetbon, A
    Donard, OFX
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (04) : 685 - 694
  • [38] Comparison of liver lead levels measured by ICP-MS in helium mode and ICP-MS in no-gas mode
    Arica, E.
    Kayaalti, Z.
    Kaya-Akyuzlu, D.
    Yener, I.
    Gok, E.
    Soylemezoglu, T.
    TOXICOLOGY LETTERS, 2015, 238 (02) : S374 - S374
  • [39] Determination of uranium in tap water by ICP-MS
    El Himri M.
    Pastor A.
    De La Guardia M.
    Fresenius' Journal of Analytical Chemistry, 2000, 367 (2): : 151 - 156
  • [40] Determination of Nutritional Value and Safety of Selenium-Enriched Watermelon by ICP-MS
    Sun, Pengfei
    Rui, Yukui
    ASIAN JOURNAL OF CHEMISTRY, 2014, 26 (07) : 2185 - 2186