Detection and quantification of intraperitoneal fluid using electrical impedance tomography

被引:29
|
作者
Sadleir, RJ
Fox, RA
机构
[1] Univ Western Australia, Dept Phys, Crawley, WA 6009, Australia
[2] Royal Perth Hosp, Dept Med Phys, Perth, WA 6847, Australia
关键词
electrical impedance tomography; intraperitoneal bleeding; quantification;
D O I
10.1109/10.915715
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A prototype electrical impedance tomography system was evaluated prior to its use for the detection of intraperitoneal bleeding, with the assistance of patients undergoing continuous ambulatory peritoneal dialysis (CAPD), The system was sensitive enough to detect small amounts of dialysis fluid appearing in subtractive images over short time periods. Uniform sensitivity to blood appearing anywhere within the abdominal cavity was produced using a post-reconstructive filter that corrected for changes in apparent resistivity of anomalies with their radial position, The image parameter used as an indication of fluid quantity, the resistivity index, varied approximately linearly with the quantity of fluid added. A test of the system's response to the introduction of conductive fluid out of the electrode plane (when a blood-equivalent fluid was added to the stomach) found that the sensitivity of the system was about half that observed in the electrode plane. Breathing artifacts were found to upset quantitative monitoring of intraperitoneal bleeding, but only on time scales short compared with the fluid administration rate. Longer term breathing changes, such as those due to variations in the functional residual capacity of the lungs, should ultimately limit the sensitivity over long time periods.
引用
收藏
页码:484 / 491
页数:8
相关论文
共 50 条
  • [21] DETECTION OF GASTROESOPHAGEAL REFLUX BY ELECTRICAL-IMPEDANCE TOMOGRAPHY
    RAVELLI, AM
    MILLA, PJ
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1994, 18 (02): : 205 - 213
  • [22] Optimized breath detection algorithm in electrical impedance tomography
    Khodadad, D.
    Nordebo, S.
    Muller, B.
    Waldmann, A.
    Yerworth, R.
    Becher, T.
    Frerichs, I
    Sophodeous, L.
    Van Kaam, A.
    Miedema, M.
    Seifnaraghi, N.
    Bayford, R.
    PHYSIOLOGICAL MEASUREMENT, 2018, 39 (09)
  • [23] Detection of small bleeds in the brain with electrical impedance tomography
    Boverman, Gregory
    Kao, Tzu-Jen
    Wang, Xin
    Ashe, Jeffrey M.
    Davenport, David M.
    Amm, Bruce C.
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (06) : 727 - 750
  • [24] Detection of Multicomponent Distribution by Electrical Impedance Spectroscopic Tomography
    Yao, Wang
    Zhao, Tong
    Liu, Xiayi
    Wang, Zhilong
    Li, Yiduo
    Miao, Li
    TWELFTH INTERNATIONAL CONFERENCE ON GRAPHICS AND IMAGE PROCESSING (ICGIP 2020), 2021, 11720
  • [25] Electrical impedance tomography for underwater detection of buried mines
    Bouchette, Gail
    Gagnon, Stephane
    Church, Philip
    Luu, Tim
    McFee, John
    DETECTION AND SENSING OF MINES, EXPLOSIVE OBJECTS, AND OBSCURED TARGETS XIII, 2008, 6953
  • [26] EVALUATION OF THE DAMAGE DETECTION CHARACTERISTICS OF ELECTRICAL IMPEDANCE TOMOGRAPHY
    Loyola, Bryan R.
    Arronche, Luciana
    LaFord, Marianne
    La Saponara, Valeria
    Loh, Kenneth J.
    PROCEEDINGS OF THE ASME CONFERENCE ON SMART MATERIALS ADAPTIVE STRUCTURES AND INTELLIGENT SYSTEMS - 2013, VOL 2, 2014,
  • [27] Electrical impedance tomography: Regularized imaging and contrast detection
    Adler, A
    Guardo, R
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (02) : 170 - 179
  • [28] Randomize-Then-Optimize for Sampling and Uncertainty Quantification in Electrical Impedance Tomography
    Bardsley, Johnathan M.
    Seppanen, Aku
    Solonen, Antti
    Haario, Heikki
    Kaipio, Jari
    SIAM-ASA JOURNAL ON UNCERTAINTY QUANTIFICATION, 2015, 3 (01): : 1136 - 1158
  • [29] Quantification of measurement error effects on conductivity reconstruction in electrical impedance tomography
    Sun, Xiang
    Lee, Eunjung
    Choi, Jung-Il
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2020, 28 (12) : 1669 - 1693
  • [30] Protective ventilation using electrical impedance tomography
    Luepschen, H.
    Meier, T.
    Grossherr, M.
    Leibecke, T.
    Karsten, J.
    Leonhardt, S.
    PHYSIOLOGICAL MEASUREMENT, 2007, 28 (07) : S247 - S260