Evaluation of a breast software model for 2D and 3D X-ray imaging studies of the breast

被引:20
|
作者
Baneva, Yanka [1 ]
Bliznakova, Kristina [2 ]
Cockmartin, Lesley [3 ]
Marinov, Stoyko [2 ]
Buliev, Ivan [2 ]
Mettivier, Giovanni [4 ,5 ]
Bosmans, Hilde [3 ]
Russo, Paolo [4 ,5 ]
Marshall, Nicholas [3 ]
Bliznakov, Zhivko [2 ]
机构
[1] Med Univ Varna, Dept Phys & Biophys, Varna, Bulgaria
[2] Tech Univ Varna, Lab Comp Simulat Med, Varna 9010, Bulgaria
[3] Univ Hosp Leuven, Dept Radiol, Med Imaging Res Ctr, Herestr 49, B-3000 Leuven, Belgium
[4] Univ Napoli Federico II, Dipartimento Fis Ettore Pancini, Naples, Italy
[5] Univ Napoli Federico II, INFN, Sez Napoli, Naples, Italy
关键词
Breast software model; Mammography; Breast software phantom; Breast imaging techniques; COMPUTED-TOMOGRAPHY; SIMULATION; PHANTOM; MAMMOGRAPHY; TOMOSYNTHESIS; PERFORMANCE;
D O I
10.1016/j.ejmp.2017.04.024
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: In X-ray imaging, test objects reproducing breast anatomy characteristics are realized to optimize issues such as image processing or reconstruction, lesion detection performance, image quality and radiation induced detriment. Recently, a physical phantom with a structured background has been introduced for both 2D mammography and breast tomosynthesis. A software version of this phantom and a few related versions are now available and a comparison between these 3D software phantoms and the physical phantom will be presented. Methods: The software breast phantom simulates a semi-cylindrical container filled with spherical beads of different diameters. Four computational breast phantoms were generated with a dedicated software application and for two of these, physical phantoms are also available and they are used for the side by side comparison. Planar projections in mammography and tomosynthesis were simulated under identical incident air kerma conditions. Tomosynthesis slices were reconstructed with an in-house developed reconstruction software. In addition to a visual comparison, parameters like fractal dimension, power law exponent beta and second order statistics (skewness, kurtosis) of planar projections and tomosynthesis reconstructed images were compared. Results: Visually, an excellent agreement between simulated and real planar and tomosynthesis images is observed. The comparison shows also an overall very good agreement between parameters evaluated from simulated and experimental images. Conclusion: The computational breast phantoms showed a close match with their physical versions. The detailed mathematical analysis of the images confirms the agreement between real and simulated 2D mammography and tomosynthesis images. The software phantom is ready for optimization purpose and extrapolation of the phantom to other breast imaging techniques. (C) 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd.
引用
收藏
页码:78 / 86
页数:9
相关论文
共 50 条
  • [31] A systematic review of the clinical effectiveness of EOS 2D/3D X-ray imaging system
    Wade, Ros
    Yang, Huiqin
    McKenna, Claire
    Faria, Rita
    Gummerson, Nigel
    Woolacott, Nerys
    EUROPEAN SPINE JOURNAL, 2013, 22 (02) : 296 - 304
  • [32] 2D/3D Cryo X-ray Fluorescence Imaging at the Bionanoprobe at the Advanced Photon Source
    Chen, S.
    Paunesku, T.
    Yuan, Y.
    Deng, J.
    Jin, Q.
    Hong, Y. P.
    Vine, D. J.
    Lai, B.
    Flachenecker, C.
    Hornberger, B.
    Brister, K.
    Jacobsen, C.
    Woloschak, G. E.
    Vogt, S.
    XRM 2014: PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2016, 1696
  • [33] Detecting Bombs in X-Ray Images of Hold Baggage: 2D Versus 3D Imaging
    Hattenschwiler, Nicole
    Mendes, Marcia
    Schwaninger, Adrian
    HUMAN FACTORS, 2019, 61 (02) : 305 - 321
  • [34] Image quality models for 2D and 3D x-ray imaging systems: A perspective vignette
    Siewerdsen, Jeffrey H. H.
    MEDICAL PHYSICS, 2023, 50 (S1) : 109 - 116
  • [35] A systematic review of the clinical effectiveness of EOS 2D/3D X-ray imaging system
    Ros Wade
    Huiqin Yang
    Claire McKenna
    Rita Faria
    Nigel Gummerson
    Nerys Woolacott
    European Spine Journal, 2013, 22 : 296 - 304
  • [36] Multi-modality 3D breast imaging with X-Ray tomosynthesis and automated ultrasound
    Sinha, Sumedha P.
    Roubidoux, Marilyn A.
    Helvie, Mark A.
    Nees, Alexis V.
    Goodsitt, Mitchell M.
    LeCarpentier, Gerald L.
    Fowlkes, J. Brian
    Chalek, Carl L.
    Carson, Paul L.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1335 - +
  • [37] Breast Cancer Screening: Opportunities and Challenges with Fully 3D Tomographic X-Ray Imaging
    Vedantham, Srinivasan
    Karellas, Andrew
    Bridge, 2022, 52 (01) : 33 - 42
  • [38] Multiscale 3D X-ray imaging
    R. Joseph Kline
    Nature Electronics, 2019, 2 : 435 - 436
  • [39] Multiscale 3D X-ray imaging
    Kline, R. Joseph
    NATURE ELECTRONICS, 2019, 2 (10) : 435 - 436
  • [40] Automatic multimodal 2D/3D image fusion of Ultrasound Computer Tomography and X-ray mammography for breast cancer diagnosis
    Hopp, Torsten
    Duric, Neb
    Ruiter, Nicole V.
    MEDICAL IMAGING 2012: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2012, 8320