Pullout strengths of orthodontic palatal mini-implants tested in vitro

被引:8
|
作者
Wu, Ju-Hui [1 ]
Wang, Huang-Chi [2 ]
Chen, Chun-Ming [1 ,2 ]
Lu, Pei-Chen [1 ]
Lai, Sheng-Tsung [1 ,2 ]
Lee, Kun-Tsung [1 ]
Du, Je-Kang [1 ,2 ]
机构
[1] Kaohsiung Med Univ Hosp, Dept Dent, Kaohsiung 80708, Taiwan
[2] Kaohsiung Med Univ, Coll Dent Med, Sch Dent, Kaohsiung, Taiwan
关键词
insertion torque; palatal mini-implant; pullout strength; skeletal anchorage; SUCCESS RATE; ANCHORAGE; THICKNESS; STABILITY;
D O I
10.1016/j.jds.2011.09.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/purpose: New modified mini-implants are used in orthodontic practice to reinforce palatal anchorage. The aim of this study was to evaluate the anchorage strengths of palatal mini-implants in terms of their vertical and horizontal pullout strengths. Materials and methods: Thirty palatal mini-implants (2 mm in diameter) of three brands (Absoanchor, Bio-Ray, and Lomas) were manually driven into artificial bone (Sawbones) to a depth of 5 mm. Their vertical and horizontal pullout strengths were measured using a material testing machine. The Kruskal-Wallis test was used to assess differences among brands (P < 0.05). Results: The pullout strengths of all the brands were significantly greater than routine orthodontic forces. The vertical pullout strength of the Absoanchor mini-implants was the lowest among the tested brands, and the horizontal pullout strengths of the Lomas and Absoanchor mini-implants were significantly higher than that of the Bio-Ray mini-implant. There was no significant relationship between the insertion torque and pullout strength in the vertical or horizontal directions. Conclusion: The pullout strengths of mini-implants were significantly greater than normal orthodontic forces. Moreover, no significant correlation was found between the insertion torque and pullout strength. Copyright (C) 2011, Association for Dental Sciences of the Republic of China. Published by Elsevier Taiwan LLC. All rights reserved.
引用
收藏
页码:200 / 204
页数:5
相关论文
共 50 条
  • [31] Design of orthodontic mini-implants contributing to implantation torque
    Katic, V.
    Spalj, S.
    Opalic, M.
    Domitran, Z.
    BIODENTAL ENGINEERING II, 2014, : 29 - 33
  • [32] Revisiting the stability of mini-implants used for orthodontic anchorage
    Yao, Chung-Chen Jane
    Chang, Hao-Hueng
    Chang, Jenny Zwei-Chieng
    Lai, Hsiang-Hua
    Lu, Shao-Chun
    Chen, Yi-Jane
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2015, 114 (11) : 1122 - 1128
  • [33] Long-term durability of orthodontic mini-implants
    Mona Aly Abbassy
    Ahmed Samir Bakry
    Khalid Hashim Zawawi
    Ali Habib Hassan
    Odontology, 2018, 106 : 208 - 214
  • [34] Predrilling of the implant site: Is it necessary for orthodontic mini-implants?
    Baumgaertel, Sebastian
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (06) : 825 - 829
  • [35] Investigation of bacteremia induced by removal of orthodontic mini-implants
    Livas, Christos
    Delli, Konstantina
    Karapsias, Stergios
    Pandis, Nikolaos
    Ren, Yijin
    EUROPEAN JOURNAL OF ORTHODONTICS, 2014, 36 (01) : 16 - 21
  • [36] Mechanical Evaluation of Orthodontic Mini-Implants of Different Lengths
    Pithon, Matheus Melo
    Fonseca Figueiredo, Daniel Santos
    Oliveira, Dauro Douglas
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (03) : 479 - 486
  • [37] Long-term durability of orthodontic mini-implants
    Abbassy, Mona Aly
    Bakry, Ahmed Samir
    Zawawi, Khalid Hashim
    Hassan, Ali Habib
    ODONTOLOGY, 2018, 106 (02) : 208 - 214
  • [38] Microflora associated with successful and failed orthodontic mini-implants
    Apel, Stephanie
    Apel, Christian
    Morea, Camillo
    Tortamano, Andre
    Dominguez, Gladys Cristina
    Conrads, Georg
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (11) : 1186 - 1190
  • [39] A MODIFIED METHOD FOR RAPID PALATAL EXPANSION ANCHORED ON MINI-IMPLANTS
    Suetenkov, Dmitry
    Firsova, Irina
    Kubaev, Aziz
    Kochkonyan, Taisiya
    Oleynikova, Natalia
    Popkova, Olga
    Evert, Evgenii
    Nasrullaev, Rakhman
    Domenyuk, Stanislav
    Konnov, Valery
    Domenyuk, Dmitry
    ARCHIV EUROMEDICA, 2022, 12 (01): : 84 - 90
  • [40] Effect of Anchor Length on the Pullout Strength of Palatal Mini Implants
    Tseng, Yu-Chuan
    Ting, Chun-Chan
    Wu, Ju-Hui
    Chen, Hong-Sen
    Chen, Chun-Ming
    IMPLANT DENTISTRY, 2017, 26 (04) : 553 - 558