Residual astigmatism produced by toric intraocular lens rotation

被引:109
|
作者
Felipe, Adelina [1 ,2 ]
Artigas, Jose M. [1 ,2 ]
Diez-Ajenjo, Amparo [1 ,2 ]
Garcia-Domene, Carmen [2 ]
Alcocer, Pablo [2 ]
机构
[1] Univ Valencia, Fac Fis, Dept Opt, E-46100 Burjassot, Valencia, Spain
[2] Univ Valencia, Fac Fis, Fdn Oftalmol Mediterraneo, E-46100 Burjassot, Valencia, Spain
来源
关键词
CORRECTING ASTIGMATISM; CATARACT PATIENTS; STABILITY; IMPLANTATION; EXPERIENCE; CENTRATION; EYES;
D O I
10.1016/j.jcrs.2011.04.036
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To analyze changes in the eye's refractive properties when a toric intraocular lens (IOL) rotates. SETTING: Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. DESIGN: Experimental study. METHODS: The matrix definition of astigmatism was used in this theoretical study and compared with another vector representation. Two methods were compared: (1) The cylinder, C, resulting from the addition of 2 cylinders C(1) and C(2) whose axes form an angle a, is obtained by the addition of 2 vectors of values C(1) and C(2) forming an angle 2a; (2) the power matrix, F, of a thin astigmatic dioptric system that decomposes naturally into 3 orthogonal components: the purely spherical part F(nes), the ortho-astigmatism F(or), and oblique astigmatism F(ob). RESULTS: The residual cylinder was one third of the corneal astigmatism when a toric IOL rotated +/- 10 degrees when the cylinder values for the cornea (C(1)) and IOL (C(2)) were equal. Nevertheless, in most cases C(1) is greater than C(2); therefore, the residual astigmatism did not change noticeably with small rotations. The angle of rotation, b, which annuls the astigmatism correction, could be obtained from the following: cos(pi + 2b) = -r/2, with r being the ratio between the IOL and cornea cylinders. CONCLUSIONS: The 2 methods gave equivalent results. When the IOL cylinder had a value different from that of the corneal astigmatism, a better choice would be a lower, rather than higher, cylinder value to reduce residual astigmatism. In general, toric IOL rotations less than 10 degrees changed the eye's refraction less than 0.50 diopter. Thus, small axis rotations are not an obstacle for satisfactory astigmatism correction with toric IOLs.
引用
收藏
页码:1895 / 1901
页数:7
相关论文
共 50 条
  • [41] Effect of long-term rotation on astigmatism following EVO-toric intraocular collamer lens implantation
    Chen, Xun
    Miao, Huamao
    Cheng, Mingrui
    Lin, I-Chun
    Li, Boliang
    Jiang, Yinjie
    Lei, Yadi
    Wang, Xiaoying
    Zhou, Xingtao
    FRONTIERS IN MEDICINE, 2023, 10
  • [42] Iris-fixated toric phakic intraocular lens for myopic astigmatism
    Munoz, Gonzalo
    Cardoner, Antoni
    Albarran-Diego, Cesar
    Ferrer-Blasco, Teresa
    Belda-Salmeron, Lurdes
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (07): : 1166 - 1175
  • [43] Treatment of high astigmatism with customized high toric intraocular lens implantation
    Navas, Alejandro
    Patricia Lopez, Karla
    Ramirez-Miranda, Arturo J.
    Graue, Enrique O.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [44] Vector analysis after toric intraocular lens implantation to correct astigmatism
    Savini, Giacomo
    Ducoli, Pietro
    Lomoriello, Domenico Schiano
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (06): : 1339 - 1339
  • [45] Toric Intraocular Lens Misalignment Inducing Astigmatism After Refractive Surgery
    Forseto, Adriana S.
    Nose, Ricardo M.
    Nose, Walton
    JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (09) : 690 - 692
  • [46] Optimized keratometry and total corneal astigmatism for toric intraocular lens calculation
    Savini, Giacomo
    Naeser, Kristian
    Schiano-Lomoriello, Domenico
    Ducoli, Pietro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (09): : 1140 - 1148
  • [47] Prediction of postoperative refractive astigmatism before toric intraocular lens implantation
    Kawahara, Atsushi
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [48] Compensation of corneal astigmatism with toric intraocular lens:: Results of a multicentre study
    Dick, H. B.
    Krummenauer, F.
    Troeber, L.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2006, 223 (07) : 593 - 608
  • [49] Effect of preoperative corneal astigmatism orientation on results with a toric intraocular lens
    Hasegawa, Yumi
    Okamoto, Fumiki
    Nakano, Shinichiro
    Hiraoka, Takahiro
    Oshika, Tetsuro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (12): : 1846 - 1851
  • [50] Correction of high astigmatism with toric intraocular lens in eyes with corneal transplant
    Devebacak, Ali
    Degirmenci, Cumali
    Selver, Ozlem Barut
    Palamar, Melis
    Egrilmez, Sait
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (02) : 927 - 932