Real-time magnetic resonance imaging of fluidized beds with internals

被引:22
|
作者
Penn, Alexander [1 ,2 ,3 ]
Boyce, Christopher M. [3 ,4 ]
Conzelmann, Nicholas [3 ]
Bezinge, Gaetan [3 ]
Pruessmann, Klaas P. [1 ,2 ]
Muller, Christoph R. [3 ]
机构
[1] Swiss Fed Inst Technol, Inst Biomed Engn, Zurich, Switzerland
[2] Univ Zurich, Zurich, Switzerland
[3] Swiss Fed Inst Technol, Dept Mech & Proc Engn, Zurich, Switzerland
[4] Columbia Univ, Dept Chem Engn, New York, NY 10027 USA
基金
瑞士国家科学基金会;
关键词
Fluidized bed reactors; Magnetic resonance imaging; Multiphase flow; Internals; Gas bubbles; Defluidized hood; HEAT-TRANSFER; BUBBLE; OBJECTS; FLOW;
D O I
10.1016/j.ces.2018.12.041
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The effect of internals on the fluidization dynamics in three-dimensional (3D) cylindrical fluidized beds was studied using real-time magnetic resonance imaging. Instantaneous snapshots of particle velocity and particle position were acquired for gas velocities U below and above the minimum fluidization velocity U-mf. Below U-mf, we found local fluidization and gas bubbling in areas adjacent to an inserted horizontal tube, likely caused by the gas locally exceeding U-mf as it flows around the insert. Above U-mf, the presence of the insert in the bed affected the fluidization dynamics. The wake region above the insert exhibited a lower average particle velocity and reduced velocity fluctuations as well as a substantially reduced number and size of gas bubbles as compared to a reference bed without internals. The extent of this wake region was found to be approximately as wide as the insert, and it extended from the top of the insert to the free surface of the bed. Moreover, the presence of internals also affected the regions below the insert by showing an increased rate of bubble formation directly below the inserted tube. The present work can provide relevant information on the design of fluidized beds with internals. Moreover, the data gathered in this work can be used to validate the accuracy of 3D numerical models of gas-solid systems. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 50 条
  • [31] Imaging of arrhythmia: Real-time cardiac magnetic resonance imaging in atrial fibrillation
    Laubrock, Kerstin
    von Loesch, Thassilo
    Steinmetz, Michael
    Lotz, Joachim
    Frahm, Jens
    Uecker, Martin
    Unterberg-Buchwald, Christina
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2022, 9
  • [32] Magnetic resonance imaging of gas dynamics in the free board of fixed beds and bubbling fluidized beds
    Boyce, C. M.
    Rice, N. P.
    Davidson, J. F.
    Sederman, A. J.
    Dennis, J. S.
    Holland, D. J.
    CHEMICAL ENGINEERING SCIENCE, 2016, 147 : 13 - 20
  • [33] Comparison of magnetic resonance real-time imaging of left ventricular function with conventional magnetic resonance imaging and echocardiography
    Schalla, S
    Nagel, E
    Lehmkuhl, H
    Klein, C
    Bornstedt, A
    Schnackenburg, B
    Schneider, U
    Fleck, E
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (01): : 95 - 99
  • [34] PERFORMANCE OF LIQUID FLUIDIZED-BEDS WITH INTERNALS
    FLASCHEL, E
    FAUQUEX, PF
    RENKEN, A
    CHEMIE INGENIEUR TECHNIK, 1982, 54 (01) : 54 - 56
  • [35] The effect of baffles on the hydrodynamics of a gas-solid fluidized bed studied using real-time magnetic resonance imaging
    Rennebaum, Hannah S.
    Brummerloh, Daniel L.
    Benders, Stefan
    Penn, Alexander
    POWDER TECHNOLOGY, 2024, 432
  • [36] Articulatory Synthesis based on Real-Time Magnetic Resonance Imaging Data
    Toutios, Asterios
    Sorensen, Tanner
    Somandepalli, Krishna
    Alexander, Rachel
    Narayanan, Shrikanth
    17TH ANNUAL CONFERENCE OF THE INTERNATIONAL SPEECH COMMUNICATION ASSOCIATION (INTERSPEECH 2016), VOLS 1-5: UNDERSTANDING SPEECH PROCESSING IN HUMANS AND MACHINES, 2016, : 1492 - 1496
  • [37] MRSIGMA: Magnetic Resonance SIGnature MAtching for real-time volumetric imaging
    Feng, Li
    Tyagi, Neelam
    Otazo, Ricardo
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (03) : 1280 - 1292
  • [38] Vocal tract morphology using real-time magnetic resonance imaging
    Sampaio, Rafael de A.
    Jackowski, Marcel P.
    2017 30TH SIBGRAPI CONFERENCE ON GRAPHICS, PATTERNS AND IMAGES (SIBGRAPI), 2017, : 359 - 366
  • [39] Real-time, cine magnetic resonance imaging for evaluation of the pediatric airway
    Faust, RA
    Remley, KB
    Rimell, FL
    LARYNGOSCOPE, 2001, 111 (12): : 2187 - 2190
  • [40] Human birth observed in real-time open magnetic resonance imaging
    Bamberg, Christian
    Rademacher, Grit
    Guettler, Felix
    Teichgraeber, Ulf
    Cremer, Malte
    Buehrer, Christoph
    Spies, Claudia
    Hinkson, Larry
    Henrich, Wolfgang
    Kalache, Karim D.
    Dudenhausen, Joachim W.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2012, 206 (06) : 505.e1 - 505.e6