Passivity Analysis and Enhancement of Voltage Control for Voltage-Source Converters

被引:0
|
作者
Liao, Yicheng [1 ]
Wang, Xiongfei [1 ]
机构
[1] Aalborg Univ, Dept Energy Technol, Aalborg, Denmark
关键词
voltage control; passivity; harmonic stability; voltage-source converter; current feedforward; GRID-CONNECTED INVERTERS; STABILITY; VSCS; STRATEGIES; DESIGN; SINGLE;
D O I
10.1109/ecce.2019.8912790
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The grid-forming control is increasingly used with distributed generation systems either in grid-connected mode or islanded mode. The voltage control is essential to a grid-forming converter, which is generally realized with a dual-loop voltage-current control. This paper evaluates the passivity of the output impedance of the dual-loop voltage control, where two voltage regulators are compared, and it turns out that the non-passive region is inevitable in the high-frequency range, which may lead to harmonic instability. An output current feedforward control is then proposed to eliminate the non-passive region below the Nyquist frequency. Lastly, simulations and experimental results corroborate the analysis.
引用
收藏
页码:5424 / 5429
页数:6
相关论文
共 50 条
  • [31] Modeling and control of single-stage voltage-source and current-source PFC converters
    Uan-Zo-Li, A
    Lee, FC
    Noon, JP
    APEC 2004: NINETEENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1-3, 2004, : 1778 - 1783
  • [32] Impact of DC-Link Voltage Control on Transient Stability of PLL-Synchronized Voltage-Source Converters
    Liu, Teng
    Wang, Xiongfei
    Liu, Fangcheng
    2022 INTERNATIONAL POWER ELECTRONICS CONFERENCE (IPEC-HIMEJI 2022- ECCE ASIA), 2022, : 435 - 439
  • [33] Isomorphic Relationships Between Voltage-Source and Current-Source Converters
    Li, Yuzhuo
    Ding, Li
    Li, Yun Wei
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (08) : 7131 - 7135
  • [34] Observer-Based Control Methods for Combined Source-Voltage Harmonics and Unbalance Disturbances in PWM Voltage-Source Converters
    Lee, Kevin
    Jahns, Thomas M.
    Lipo, Thomas A.
    Blasko, Vladimir
    Lorenz, Robert D.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2009, 45 (06) : 2010 - 2021
  • [35] Stability Analysis of Grid-Connected Voltage-Source Converters with Unbalanced Loads
    Diene, Oumar
    Nascimento, Claudionor F.
    Watanabe, Edson H.
    2017 IEEE 12TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS (PEDS), 2017, : 208 - 213
  • [36] The Use of Voltage-Source Active Rectifier to Minimize the Effect of Supply Voltage Drops on Converters
    Kus, Vaclav
    Josefova, Tereza
    PROCEEDINGS OF THE 2015 16TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2015, : 242 - 245
  • [37] Catastrophic Bifurcation in Three-Phase Voltage-Source Converters
    Huang, Meng
    Wong, Siu-Chung
    Tse, Chi K.
    Ruan, Xinbo
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2013, 60 (04) : 1062 - 1071
  • [38] Improved ADC Model of Voltage-Source Converters in DC Grids
    Mu, Qing
    Liang, Jun
    Zhou, Xiaoxin
    Li, Yalou
    Zhang, Xing
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (11) : 5738 - 5748
  • [39] Optimizing the Dynamic Behavior of Direct Controls of Voltage-source Converters
    Veszpremi, Karoly
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2009, 37 (09) : 1014 - 1035
  • [40] Direct coupling of solar plants and electrolyzers with voltage-source converters
    Geske, Martin
    Ablakovic, Dino
    Jalili, Kamran
    Keller, Christian
    2024 IEEE SIXTH INTERNATIONAL CONFERENCE ON DC MICROGRIDS, ICDCM 2024, 2024,