Particle size monitoring in a fluidized bed using pressure fluctuations

被引:18
|
作者
Davies, Clive E. [1 ]
Carroll, Alison [2 ]
Flemmer, Rory [1 ]
机构
[1] Massey Univ, Inst Technol & Engn, Palmerston North, New Zealand
[2] Carroll Consulting, Taupo, New Zealand
关键词
fluidized bed; particle size; pressure fluctuations; pressure standard deviation; size monitoring;
D O I
10.1016/j.powtec.2007.02.026
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Starting from the premise that the standard deviation, up, of the pressure fluctuations in a fluidized bed is linearly proportional to excess gas velocity, it follows that up is a function of particle size. This relationship has previously been recognised as a potential route to the continuous monitoring of particle size in fluidized bed processing, and is attractive because of the relative ease with which pressure and pressure fluctuations can be measured. Simple expressions with no fitted parameters can be derived for the case where the constant of proportionality between up and excess gas velocity is unaltered by changes in mean particle size. The results of experiments with mixtures of silica sand prepared by mixing two base batches, with a different mean size, in incrementally varying proportions provide good support for the general validity of the model. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:307 / 311
页数:5
相关论文
共 50 条
  • [31] Influence of the nature of the Roots blower on pressure fluctuations in a fluidized bed
    Chyang, CS
    Lin, YC
    POWDER TECHNOLOGY, 2002, 127 (01) : 19 - 31
  • [32] Mathematical analysis of characteristic pressure fluctuations in a bubbling fluidized bed
    Xiang, Jie
    Li, Qinghai
    Wang, Aiyue
    Zhang, Yanguo
    POWDER TECHNOLOGY, 2018, 333 : 167 - 179
  • [33] Identification of the state of a magneto-fluidized bed by pressure fluctuations
    Laxminarayan Institute of Technology, Nagpur University, India
    Int. J. Chem. Reactor Eng., 2006, (1-17):
  • [34] Effect of bed size on the gas-solid flow characterized by pressure fluctuations in bubbling fluidized beds
    Xiang, Jie
    Zhang, Yanguo
    Li, Qinghai
    PARTICUOLOGY, 2019, 47 : 1 - 9
  • [35] Effects of bed particle size on beat transfer in circulating fluidized bed boilers
    Andersson, BA
    POWDER TECHNOLOGY, 1996, 87 (03) : 239 - 248
  • [36] Influence of drying conditions on the acacia gum particle growth in fluidized bed agglomeration: in-line monitoring of particle size
    Rosa, J. G.
    Nascimento, R. F.
    Andreola, K.
    Taranto, O. P.
    IDS'2018: 21ST INTERNATIONAL DRYING SYMPOSIUM, 2018, : 1439 - 1446
  • [37] Measurement of Floating Particle Size Distribution by Using a Solid-Liquid Fluidized Bed
    Kimura, Satoru
    Ohira, Yuichi
    Obata, Eiji
    KAGAKU KOGAKU RONBUNSHU, 2009, 35 (06) : 596 - 601
  • [38] CONTINUOUS PARTICLE SIZE DISTRIBUTIONS IN A BUBBLING FLUIDIZED BED USING DISCRETE ELEMENT METHOD
    de Souza Braun, Meire Pereira
    Caserta, Alice Jordam
    Navarro, Helio Aparecido
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 7, PTS A-D, 2013, : 2475 - 2484
  • [39] Influence of Particle Size on Vacuum-Fluidized Bed Drying
    Kozanoglu, B.
    Martinez, J.
    Alvarez, S.
    Guerrero-Beltran, J. A.
    Welti-Chanes, J.
    DRYING TECHNOLOGY, 2012, 30 (02) : 138 - 145
  • [40] PARTICLE-SIZE EFFECTS IN FLUIDIZED-BED COMBUSTION
    GOLAN, LP
    CHERRINGTON, DC
    DIENER, R
    SCARBOROUGH, CE
    WEINER, SC
    CHEMICAL ENGINEERING PROGRESS, 1979, 75 (07) : 63 - 72