Simulation Study of a Shield-Free Directional Gamma-Ray Detector Using Small-Angle Compton Scattering

被引:0
|
作者
Kitayama, Yoshiharu [1 ]
Terasaka, Yuta [1 ]
Sato, Yuki [1 ]
Torii, Tatsuo [1 ]
机构
[1] Japan Atom Energy Agcy, Remote Syst & Sensing Technol Div, Collaborat Labs Adv Decommissioning Sci, Fukushima 9791151, Japan
关键词
CAMERA;
D O I
10.1115/1.4048902
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Gamma-ray imaging is a technique for visualizing the spatial distribution of radioactive materials. Gamma-ray imaging has recently been applied to research on environmental restoration and decommissioning of the Fukushima Daiichi Nuclear Power Station (FDNPS). In this paper, we present an elemental technology study of the gamma-ray imager using small-angle scattering (GISAS), which is intended for application at the FDNPS decommissioning site. GISAS consists of a set of directional gamma-ray detectors that do not require a shield. In this study, we investigated the feasibility of a shield-free directional gamma-ray detector by simulation. The simulation result suggests that by measuring scattered-electron energies of several keV using a scatterer detector, gamma rays with ultrasmall-angle scattering could be selected. Using Compton scattering kinematics, a shield-free detector with a directivity of about 10 deg may be feasible. By arranging the directional gamma-ray detectors in an array, we expect to be able to realize the GISAS, which is small, light, and capable of quantitative measurement.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Small-angle X-ray-scattering study of supercritical trifluoromethane
    Nishikawa, K
    Morita, T
    JOURNAL OF PHYSICAL CHEMISTRY B, 1997, 101 (08): : 1413 - 1418
  • [42] A small-angle X-ray scattering study of powder compaction
    Laity, Peter R.
    Cameron, Ruth E.
    POWDER TECHNOLOGY, 2008, 188 (02) : 119 - 127
  • [43] SMALL-ANGLE X-RAY-SCATTERING STUDY OF A LAMELLAR MESOPHASE
    JOUSMA, H
    GOORIS, GS
    JOOSTEN, JGH
    JUNGINGER, HE
    PHARMACEUTISCH WEEKBLAD-SCIENTIFIC EDITION, 1986, 8 (01) : 97 - 97
  • [44] SMALL-ANGLE X-RAY-SCATTERING STUDY OF PHASE-SEPARATION IN GLASSES USING A NEW POSITION-SENSITIVE DETECTOR
    BRAS, S
    CRAIEVICH, A
    SANCHEZ, JM
    WILLIAMS, C
    ZANOTTO, ED
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 208 (1-3): : 489 - 494
  • [45] SMALL-ANGLE X-RAY-SCATTERING SYSTEM WITH LINEAR POSITION-SENSITIVE DETECTOR
    FOROUHI, AR
    SLEAFORD, B
    PEREZMENDEZ, V
    DEFONTAINE, D
    FODOR, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (01) : 275 - 278
  • [46] A new detector for time-resolved small-angle X-ray scattering studies
    De Lurgio, Patrick M.
    Hessler, Jan P.
    Weizeorick, John T.
    Kreps, Andrew S.
    Molitsky, Michael J.
    Naday, Istvan
    Drake, Gary R.
    Jennings, Guy
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1215 - 1222
  • [48] SOLUTION SMALL-ANGLE X-RAY-SCATTERING STUDIES ON MYOSIN WITH A MULTIWIRE AREA DETECTOR
    FARUQI, AR
    CROSS, RA
    KENDRICKJONES, J
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1991, 24 : 852 - 856
  • [49] ON THE APPLICATION OF A ONE-DIMENSIONAL DETECTOR IN SMALL-ANGLE X-RAY-SCATTERING STUDIES
    MOGILEVSKY, LY
    DEMBO, AT
    STUDIA BIOPHYSICA, 1983, 97 (02): : 147 - 148
  • [50] SMALL-ANGLE COMPTON-SCATTERING OF EU-152 AND EU-154 GAMMA-RAYS
    DOW, JC
    HICKS, GC
    TAYLOR, RB
    WHITTINGHAM, IB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 255 (1-2): : 78 - 85