MRI-guided attenuation correction in torso PET/MRI: Assessment of segmentation-, atlas-, and deep learning-based approaches in the presence of outliers

被引:12
|
作者
Arabi, Hossein [1 ]
Zaidi, Habib [1 ,2 ,3 ,4 ]
机构
[1] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
[2] Univ Geneva, Neuroctr, Geneva, Switzerland
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[4] Univ Southern Denmark, Dept Nucl Med, Odense, Denmark
基金
瑞士国家科学基金会;
关键词
body truncation; deep learning; metal artifact; PET; MRI; quantitative PET; CT IMAGES; GENERATION;
D O I
10.1002/mrm.29003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose We compare the performance of three commonly used MRI-guided attenuation correction approaches in torso PET/MRI, namely segmentation-, atlas-, and deep learning-based algorithms. Methods Twenty-five co-registered torso F-18-FDG PET/CT and PET/MR images were enrolled. PET attenuation maps were generated from in-phase Dixon MRI using a three-tissue class segmentation-based approach (soft-tissue, lung, and background air), voxel-wise weighting atlas-based approach, and a residual convolutional neural network. The bias in standardized uptake value (SUV) was calculated for each approach considering CT-based attenuation corrected PET images as reference. In addition to the overall performance assessment of these approaches, the primary focus of this work was on recognizing the origins of potential outliers, notably body truncation, metal-artifacts, abnormal anatomy, and small malignant lesions in the lungs. Results The deep learning approach outperformed both atlas- and segmentation-based methods resulting in less than 4% SUV bias across 25 patients compared to the segmentation-based method with up to 20% SUV bias in bony structures and the atlas-based method with 9% bias in the lung. The deep learning-based method exhibited superior performance. Yet, in case of sever truncation and metallic-artifacts in the input MRI, this approach was outperformed by the atlas-based method, exhibiting suboptimal performance in the affected regions. Conversely, for abnormal anatomies, such as a patient presenting with one lung or small malignant lesion in the lung, the deep learning algorithm exhibited promising performance compared to other methods. Conclusion The deep learning-based method provides promising outcome for synthetic CT generation from MRI. However, metal-artifact and body truncation should be specifically addressed.
引用
收藏
页码:686 / 701
页数:16
相关论文
共 48 条
  • [21] Development and benchmarking of a Deep Learning-based MRI-guided gross tumor segmentation algorithm for Radiomics analyses in extremity soft tissue sarcomas
    Peeken, Jan C.
    Etzel, Lucas
    Tomov, Tim
    Muench, Stefan
    Schuettrumpf, Lars
    Shaktour, Julius H.
    Kiechle, Johannes
    Knebel, Carolin
    Schaub, Stephanie K.
    Mayr, Nina A.
    Woodruff, Henry C.
    Lambin, Philippe
    Gersing, Alexandra S.
    Bernhardt, Denise
    Nyflot, Matthew J.
    Menze, Bjoern
    Combs, Stephanie E.
    RADIOTHERAPY AND ONCOLOGY, 2024, 197
  • [22] Deep learning-guided attenuation and scatter correction without using anatomical images in brain PET/MRI
    Bortolin, Karin
    Arabi, Hossein
    Zaidi, Habib
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [23] Test-retest repeatability of deep learning-based attenuation correction for chest FDG PET/MRI using Zero-TE MRI and unpaired PET/CT data
    Nogami, Munenobu
    Matsuo, Hidetoshi
    Nishio, Mizuho
    Zeng, Feibi
    Tachibana, Miho
    Inukai, Junko
    Kurimoto, Takako
    Kubo, Kazuhiro
    Okazawa, Hidehiko
    Murakami, Takamichi
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [24] Organ Specific Deep Learning-Based Correction of Inaccurate Auto-Segmentation on Abdominal MRI
    Sarosiek, C.
    Zhang, Y.
    Ding, J.
    Amjad, A.
    Dang, N. P.
    Zarenia, M.
    Conlin, R.
    Li, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : S118 - S119
  • [25] Truncation compensation and metallic dental implant artefact reduction in PET/MRI attenuation correction using deep learning-based object completion
    Arabi, Hossein
    Zaidi, Habib
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (19):
  • [26] PET attenuation correction of chest FDG PET/MRI: Deep learning-based denoising and pseudo-CT generation using fast zero-TE MRI and unpaired PET/CT data
    Nogami, M.
    Matsuo, H.
    Nishio, M.
    Tachibana, M.
    Inukai-Inoue, J.
    Zeng, F.
    Kubo, K.
    Kurimoto, T.
    Murakami, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S486 - S487
  • [27] Atlas-based segmentation of T1-weighted and Dute MRI for calculation of attenuation correction maps in PET-MRI of brain tumor patients
    Poynton, Clare
    Chonde, Daniel
    Sabunca, Mert
    Kong, Jian
    Gollub, Randy
    Hooker, Jacob
    Catana, Ciprian
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [28] Human factors in the clinical implementation of deep learning-based automated contouring of pelvic organs at risk for MRI-guided radiotherapy
    Abdulkadir, Yasin
    Luximon, Dishane
    Morris, Eric
    Chow, Phillip
    Kishan, Amar U.
    Mikaeilian, Argin
    Lamb, James M.
    MEDICAL PHYSICS, 2023, 50 (10) : 5969 - 5977
  • [29] Deep Learning Based Attenuation Correction of PET/MRI in Pediatric Brain Tumor Patients: Evaluation in a Clinical Setting
    Ladefoged, Claes Nohr
    Marner, Lisbeth
    Hindsholm, Amalie
    Law, Ian
    Hojgaard, Liselotte
    Andersen, Flemming Littrup
    FRONTIERS IN NEUROSCIENCE, 2019, 12
  • [30] Deep learning-based quick MLC sequencing for MRI-guided online adaptive radiotherapy: a feasibility study for pancreatic cancer patients
    Ahunbay, Ahmet
    Paulson, Eric
    Ahunbay, Ergun
    Zhang, Ying
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (04):